HVP MSYSTEM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
MODEL: HVP HVP SPECIFICATIONS ES-3421 Rev.13 Page 1/3 http://www.m-system.co.jp/ Space-saving Plug-in Signal Conditioners H-UNIT I/P TRANSDUCER Functions & Features
- Converting a DC input into a proportional standard pneumatic signal
- Semiconductor pressure sensor in the feedback circuit
- High resolution
- No mounting position effect
- High-density mounting Typical Applications
- Converting a 4 – 20 mA from a PID controller into a pneumatic signal HVP H•UNIT 25 (.98) 150 (5.91) mm (inch) 120 (4.72) MODEL: HVP–[1]–R[2]
ORDERING INFORMATION
- Code number: HVP-[1]-R[2] Specify a code from below for each of [1] and [2]. (e.g. HVP-6-R/A2S/P7) [1] INPUT Current A: 4 – 20 mA DC (Input resistance 250 Ω) Voltage 6: 1 – 5 V DC (Input resistance 1 MΩ min.) POWER INPUT DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) [2] OPTIONS (multiple selections) Output blank: 0.2 – 1.0 kgf/cm2 /A1S: 19.6 – 98.1 kPa /A2S: 20 – 100 kPa /A3S: 20.7 – 103.4 kPa /A2: 0.2 – 1.0 bar /A3: 3 – 15 psig Pneumatic Connection blank: Rc 1/4" /P7: 1/4" NPT fitting
RELATED PRODUCTS
Mounting Block is required. See the data sheet for model MB.
- Code number of the Mounting Block (e.g. MB-08) GENERAL SPECIFICATIONS Construction: Plug-in Connection Input & power input: M3.5 screw terminals (torque 0.8 N·m) Pneumatic: Rc 1/4" or 1/4" NPT female; (torque ≤ 12 N·m) Material
- Housing: Flame-resistant resin (black)
- Base socket: Die cast aluminium
- Valve section: Die cast aluminium
- Screw terminals: Nickel-plated steel; Isolation: Input to power Zero adjustment: -5 to +5 % (front) Span adjustment: 95 to 105 % (front) INPUT SPECIFICATIONS ■ DC Current: Shunt resistor attached to the input terminals (0.5 W) OUTPUT SPECIFICATIONS ■ Output: 19.6 – 98.1 kPa, 0.2 – 1.0 kgf/cm2 20 – 100 kPa, 0.2 – 1.0 bar 20.7 – 103.4 kPa, 3 – 15 psig The output goes below 0 % if the input loop is open. Maximum air delivery: 60 Nl/minute (2.1 SCFM) Maximum air exhaust: 60 Nl/minute (2.1 SCFM) INSTALLATION Supply pressure: 140 kPa (1.4 kgf/cm2, 1.4 bar, 20 psig) ±10 %. Use dry air containing no carbon black or other foreign particles. To ensure reliability use an air filter (0.01 microns). Air consumption: 6 Nl/minute (0.21 SCFM) Current consumption: Approx. 30 mA Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface; Standard Rack Mounting Frame (BX-
MODEL: HVP HVP SPECIFICATIONS ES-3421 Rev.13 Page 2/3 http://www.m-system.co.jp/ 16H) available Weight: 400 g (0.88 lb) PERFORMANCE in percentage of span Accuracy: ±0.3 % including linearity and repeatability Linearity: ±0.2 % Repeatability: 0.1 % Temp. coefficient: ±0.05 %/°C (±0.03 %/°F) Response time: ≤ 3 sec. (0 – 90 %) Mounting position effect: ±0.1 % (all dimensions) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 500 V AC @ 1 minute (input to power)
1500 V AC @ 1 minute (input or power to housing)
EXTERNAL DIMENSIONS unit: mm (inch) 1 2 3 4 25 (.98) 120 (4.72) 80 (3.15) 48 (1.89) 25 (.98) approx. 15 (.59) 2–4.3 (.17) dia. MTG HOLE MOUNTING BLOCK 123 (4.84) 150 (5.91) SUPPLY CONNECTION Rc 1/4” or 1/4” NPT OUTPUT CONNECTION *NPT FITTING
- When mounting, no extra space is needed between units. 4–M3.5 SCREW *Fitting is provided for 1/4” NPT connection. 8.3 (.32)
MODEL: HVP HVP SPECIFICATIONS ES-3421 Rev.13 Page 3/3 http://www.m-system.co.jp/ TERMINAL ASSIGNMENTS unit: mm (inch) 1 2 7 (.28) Input shunt resistor attached for current input. INPUT RESISTOR (model: REM) SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Base Socket Pilot Valve Z S POWER SUPPLY PRESSURE P / I Converter Deviation Amplifier+ *INPUT R Driver ELECTRO- MAGNETIC FLAPPER OUTPUT *Input shunt resistor attached for current input. Specifications are subject to change without notice.