Features
- Ultra low ESR for high power density
- UL recognized
Applications
- Electric, Gas, Water smart meters
- Controllers
- RF radio power
- Solar capture
- Storage servers
- Pulse power
- Backup power Pb HALOGEN HFFREE
www.eaton.com/elx Ratings Capacitance 1.0 F to 100 F Maximum working voltage 2.7 V Surge voltage 3.0 V Capacitance tolerance -10% to +30% Operating temperature range -40 °C to +65 °C Extended temperature range -40 °C to +85 °C (with linear voltage derating to 2.3 V @ 85 °C) Specifications Capacitance1 (F) Part Number Maximum Initial ESR1 (Ω) Nominal Leakage Current2 (µA) Stored Energy3 (mWh) Peak Power4 (W) Pulse Current5 (A) Continuous Current6 (A) Typical Thermal Resistance7, Rth (°C/W) Short Circuit Current8 (A) 3 HV0820-2R7305-R 0.080 15 3.0 23 3.3 1.6 76 34 5 HV1020-2R7505-R 0.040 20 5.1 46 5.6 2.3 73 68 6 HV0830-2R7605-R 0.040 20 6.1 46 6.5 2.8 47 68 10 HV1030-2R7106-R 0.034 23 10 54 10 3.3 40 79 15 HV1325-2R7156-R 0.030 23 15 61 14 3.1 53 90 25 HV1625-2R7256-R 0.027 45 25 68 20 3.4 47 100 35 HV1245-2R7356-R 0.020 51 35 91 28 5.8 22 135 35 HV1635-2R7356-R 0.024 51 35 76 26 4.0 39 113 60 HV1840-2R7606-R 0.018 110 61 101 39 5.7 26 150 100 HV1860-2R7107-R 0.012 260 101 152 61 11 10 225 Repeated short circuit current will permanently damage the leads and cause an open failure. Performance Parameter Capacitance change (% of initial value) ESR (% of maximum initial value) Life (1000 hours @ +65 °C @ 2.7 Vdc) ≤ 30% ≤ 200% Storage (3 years, uncharged, <+35 °C) ≤ 5% ≤ 110% Cycle Life9 (500,000 cycles) ≤ 30% ≤ 200% 1. Capacitance and Equivalent Series Resistance (ESR) measured according to IEC62391-1 at +20 °C, with current in milliamps (mA) = 8*C*V 2. Leakage current at 20 °C after 72 hour charge and hold 3. Energy (mWh) = ½*C*V 2 *1000 3600 4. Peak Power (W) = V 2 4*ESR 5. Pulse Current in Amps (A), 1 second discharge from rated voltage to half rated voltage = ½*C*V (1+ESR*C) 6. Continuous current with a 15 °C temperature rise. Continuous current (A) = 7. Thermal resistance (Rth) cell body temperature to ambient in open air in degrees C per Watt (°C/W) 8. Short circuit current is for safety information only. Do not use as operating current. 9. Cycling between rated voltage and half voltage, 3 seconds rest at +20 °C Safety and Certifications Regulatory UL810a, RoHS Warnings Do not overvoltage, do not reverse polarity Shipping UN3499, <0.3Wh, Non-hazardous goods
www.eaton.com/elx Part numbering system HV 1860 –2R7 10 7 -R Family code Size reference (mm) Voltage (V) R = decimal Capacitance (μF) Value Multiplier RoHS compliant HV = Family Code Diameter = 18 Length = 60 2R7 = 2.7 V Example 107= 10 x 107 μF or 100 F Packaging information
- Standard packaging: Bulk, 100 units per bag (8 mm - 13 mm diameter)
- 16 mm - 18 mm diameter products: Bulk package quantity varies by size. Dimensions (mm) Part Number ØD nominal ØD maximum L maximum F ±0.50 Ød ±0.02 C minimum C’ minimum Typical mass (grams/pieces) Part marking
- Manufacturer
- Capacitance (F)
- Max operating voltage (V)
- Family code (or part number)
- Polarity L D C dC’ F Longer lead is positive
www.eaton.com/elx T emperature vs. Capacitance and ESR 20% 40% 60% 80% 100% 120% 140% 160% 180% -60 -40 -20 02 04 06 08 0 Change from 20°C Value Temperature (°C) Capacitance ESR
1000 Eaton Boulevard
Cleveland, OH 44122 United States www.eaton.com/elx © 2016 Eaton All Rights Reserved Printed in USA Publication No. 4376-BU-MC16012 May 2016 Eaton is a registered trademark. All other trademarks are property of their respective owners. Life Support Policy: Eaton does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Wave solder profile Profile Feature Standard SnPb Solder Lead (Pb) Free Solder Preheat and soak • Temperature max. (Tsmax) 100 °C 100 °C
- Time max. 60 seconds 60 seconds D preheat to max Temperature 160 °C max. 160 °C max. Peak temperature (TP)* 220 °C – 260 °C 250 °C – 260 °C Time at peak temperature (tp) 10 seconds max 5 seconds max each wave 10 seconds max 5 seconds max each wave Ramp-down rate ~ 2 K/s min ~3.5 K/s typ ~5 K/s max ~ 2 K/s min ~3.5 K/s typ ~5 K/s max Time 25 °C to 25 °C 4 minutes 4 minutes Manual solder +350 °C, 4-5 seconds. (by soldering iron), generally manual, hand soldering is not recommended. Cleaning/Washing Avoid cleaning of circuit boards, however if the circuit board must be cleaned use static or ultrasonic immersion in a standard circuit board cleaning fluid for no more than 5 minutes and a maximum temperature of +60 °C. Afterwards thoroughly rinse and dry the circuit boards. In general, treat supercapacitors in the same manner you would an aluminum electrolytic capacitor. Temperature Time Tsmin Tsmax Tstyp Tp tp First Wave Second Wave Preheat area Cool down area