ABS400 BEL | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 9
Technical content
The ABS/MBS400 Series of AC-DC power supplies provides up to
400 W of regulated output power through wide input voltage range
90 – 264 VAC in single outputs of 12, 24, 36 or 48 VDC. The ABS/MBS400 Series comes in a 83.0 x 212.0 x 42.0 mm form factor, offering 12 and 5 VSB standby outputs and a full set of protection features. Available control signals include Power Good (Power_OK), remote On/off (PS_ON) and remote sense (+RS). The sealed and full potted package allows an IP67 ingress protection index and can be installed in contact with thermo - conductive part of the system to transfer heat by conduction. The ABS400/MBS Series complies with the latest international safety standards for IT and medical equipment, offering 2x MoPP protection grade and displays the CE -Mark for the European Low Voltage Directive (LVD).
- Universal input voltage range (90 – 264 VAC)
- Input surge current limiting
- 400 W rated power (440 W peak up to 10 s)
- High efficiency up to 94%
- Low stand-by consumption (<0.5 W)
- 12, 24, 36 and 48 V standard output voltages
- Active PFC, EN61000-3-2 compliant (Class C, >25% load).
- Low earth / touch leakage current
- Over temperature protection, OV, OC and SC protections
- Stand by +5 V, 2 A and auxiliary / fan 12 VDC, 1 A outputs.
- Remote On / Off signal
- Power good and remote sense signals
- Sealed, potted package IP67 rated, fits 1U applications
- Medical safety approval to IEC 60601-1 3rd edition, 2x MoPP rated and BF appliances compatible.
- IT safety approval to UL/IEC 60950-1
- Medical version compatible with 4000 m altitude operation
- Optional heatsink accessory available (HSKIT-400-XBS)
- Suitable for harsh environments
- Video Wall Display & Entertainment
- Industrial Process Control
- Telecommunications
- Laboratory Equipment
- Test & Measurement Equipment
- Medical Applications
2 ABS/MBS400 Series
tech.support@psbel.com MODEL NUMBER PACKAGE & COOLING INPUT VOLTAGE RANGE [VAC] NOM. OUTPUT VOLTAGE [VDC] MAX. OUTPUT POWER [W] MAX. OUTPUT CURRENT [A] DIMENSIONS ABS400-1012 Sealed Chassis Convection / Conduction 90 - 264 12 400 33.3 Dimensions without heatsink: 83.0 x 212.0 x 42.0 mm 3.27 x 8.34 x 1.65 in Dimensions with heatsink: 83.0 x 212.0 x 70.1 mm 3.27 x 8.34 x 2.76 in MBS400-1012 ABS400-1024 Sealed Chassis Convection / Conduction 90 - 264 24 400 16.7 MBS400-1024 ABS400-1036 Sealed Chassis Convection / Conduction 90 - 264 36 400 11.1 MBS400-1036 ABS400-1048 Sealed Chassis Convection / Conduction 90 - 264 48 400 8.3 MBS400-1048 HSKIT-400-XBS - Heatsink accessory (optional) Mounting kit includes 4x screws, M4x10, and the thermally conductive graphite sheet PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT AC Input Voltage PS starts and operates at 90 VAC at all load conditions 90 100-240 264 VRMS DC Input Voltage 170 - 270 VDC Input Frequency 47 50/60 440 Hz Input Current RMS at 180 VAC, maximum load, 50 / 60 Hz RMS at 90 VAC, maximum load, 50 / 60 Hz - - 2.5 5.0 A Inrush Current 265 VAC, 25 °C ambient, cold start. 20 A Fusing 2x Time Lag 6.3 A, 250 V on both L and N - - 6.3 A Efficiency At 115 VAC 20% rated load 90 - - 100 % load 92 - - At 230 VAC 20% full load 90 - - 50 – 100 % full load 94 - - Input Power Consumption Power on, 115-230 VRMS, no load Stand by, 115-230 VRMS, no load 0.4 1.5 0.5 W Power Factor At full rated load, 115 VAC, 60 Hz and 230 VAC, 50 Hz input voltages 0.95 - - - Harmonic Current Fluctuations and Flicker Complies with EN-61000-3-2 Class C at 230 VAC 50 Hz, load >50 W. Complies with EN-61000-3-3 at nominal voltages and full load. Leakage Current Normal conditions, 240 VRMS, 60 Hz. 300 µA
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2020 Bel Power Solutions & Protection BCD.01062_A PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT V1 Output Voltage ±0.5% set point accuracy on all outputs V V1 Output Power Rating All models, convection cooling All models, conduction cooling / heat sink All models, peak power (≤ 10 s) 350 400 440 W V1 Output Current * Conduction (with heatsink) V1: 12 VDC V1: 24 VDC V1: 36 VDC V1: 48 VDC 33.3 16.7 11.1 8.3 A Convection (without heatsink) V1: 12 VDC V1: 24 VDC V1: 36 VDC V1: 48 VDC 29.2 14.6 9.7 7.3 A V1 Voltage Adjustment Range ±5 - - %V1 V1 Load-Line-Cross Regulation VAC: 90 – 264 VRMS V1 Load: 0 – 33.3 A (12 V) 0 – 16.7 A (24 V) 0 – 11.1 A (36 V) 0 – 8.3 A (48 V) V2 Load: 0 – 1 A 5VSB Load: 0 – 2 A - - ±2 %V1 V1 Line Regulation VAC: 90 – 264 VRMS - - ±0.1 %V1 Transient Response (Voltage Deviation) V1, 5VSB 25% load changes at 1 A/µs 12 V at 2200 µF Load / IOUT> 0.5 A 24 V at 1000 µF Load / IOUT> 0.5 A 36 V at 820 µF Load / IOUT> 0.5 A 48 V at 560 µF Load / IOUT> 0.5 A 5VSB at 560 µF Load / IOUT> 0.1 A - - ±5 %V1 %5VSB V1 Ripple & Noise All models, Peak-to-peak, 20 MHz BW. 100 nF ceramic and 10µF tantalum to the load. - - 1 %V1 Start-up Rise Time 90<VIN<264, any load conditions. 5 - 85 ms Start-up Delay V1 in regulation after PS_ON is asserted V1 in regulation after AC is applied 5VSB in regulation after AC is applied - - 200 750 500 ms Turn-on Overshoot At 500 mA output current, V1 in regulation within 50 ms. - %V1 %V2 %VSB Hold-up Time At nominal VIN, 400 W, for all outputs At nominal VIN, 365 W, for all outputs At nominal VIN, 200 W, for all outputs ms Minimum Load * All models; V1, V2 and 5VSB 0 - - A Maximum Load Capacitance At nominal VIN, 25 °C ambient 12 V 24 V 36 V 48 V 33000 16000 10000 7000 µF Temperature Drift -1.2 - +1.2 mV/°C V2 Output Voltage All versions. Load on V2: from 5 to 1000 mA Load on V1: from 0.1 to 16.7 A 11.25 12.5 13.75 V V2 Output Current All models, convection/forced air cooling - - 1 A V2 Ripple Peak-to-Peak measured at 20 MHz Bandwidth. 240 mV 5VSB Output Voltage All models (3% set point accuracy) - 5 - V 5VSB Output Current All models, convection cooling All models, conduction cooling / heat sink 1.5 2 A
4 ABS/MBS400 Series
mounted, must not exceed 400 W up to 50 °C, and 300 at 70 °C ambient temperature. 350 W up to 50 °C, and 240 W at 70 °C ambient temperature. See de -rating curves below. *** When the load on the main output is less than 100 mA, V2 output voltage might regulate below its minimum value. Figure 2. Power Derating Curves
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2020 Bel Power Solutions & Protection BCD.01062_A Base signals and controls are accessible from signal connector P204. SIGNAL DESCRIPTION / CONDITION MIN NOM MAX UNIT PS_ON Active low, +5 V TTL signal compatible. Input low voltage 0 - 2.0 V Input high voltage (IIN = 200 µA) 3.0 - - V V1 and V2 disabled when PS_ON is open 5VSB not affected by PS_ON V1 and V2 enabled with PS_ON connected to RTN P_OK +5 V TTL compatible Logic level low (<10 mA sinking) - - 0.7 V Logic level high (100 µA sourcing) 2.4 - 5 V Low to high time after V1 in regulation 0.05 - 0.1 s Power down warning time 1 - - ms 5VSB output Active and in regulation after a 90<VAC<264 is applied - - 200 ms 5VSB not affected by PS_ON Above waveforms are expected with AC Input ON/OFF: Standby on - Main outputs on 50 ms ≤ T1 ≤ 250 ms Main output Rise Time 5 ms ≤ T2 ≤ 110 ms
5 VSB rise time 4 ms ≤ T10 ≤ 20 ms
Main outputs On – P_OK delay 25 ms ≤ T3 ≤ 100 ms Power down warning 1 T4 ≥ 1 ms Main Output off – Standby off 2 T5 ≥ 1.2 s Hold-up time (AC off – P_OK low) T6 ≥ 15 ms (115/ 230 VAC) AC_ON - Standby turn on time T7 ≤ 500 ms
6 ABS/MBS400 Series
tech.support@psbel.com Above waveforms are expected with PS_ON Signal ON/OFF state change: Main Output Rise Time 5 ms ≤ T2 ≤ 110 ms Main Outputs on – P_OK delay 25 ms ≤ T3 ≤ 100 ms Power down warning 1 1 ms ≤ T4 ≤ 5 ms PS_ON - Main Output (off) Timing T8 ≤ 1 ms PS_ON - Main Output (on) Timing T9 ≤ 200 ms 1 T4 parameter measurement setup will assume at least 10% of the maximum load on each output. 2 T5 parameter measurement setup will assume 50% of the maximum load on 5V SB. PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT Input Under Voltage Auto-recovering, hiccup mode. 60 75 - VAC Input Fuse 2x Time Lag 6.3 A, 250 V on L and N - - 6.3 A Over Current At nominal input voltages. V1: Hiccup mode. auto-recovering. V2: PTC limiting, auto-recovering. 5VSB: Hiccup mode, auto-recovering. 110 - 155 %I1MAX Short Circuit At nominal input voltages. V1: Hiccup mode. auto-recovering. V2: PTC limiting, auto-recovering. 5VSB: Hiccup mode, auto-recovering. - - - Over Voltage 12V 24V 48V 5VSB Shut down, latch-off. 110 - 136 %VNOM Over Temperature (on primary stage) Shut down, latch off. - - - Over Temperature (on secondary side) Hiccup mode, auto-recovering. - - - Isolation Primary to Secondary Reinforced (2x MoPP) 5660 4000 VDC VAC Isolation Input to Earth Basic (1x MoPP) 1500 VAC Isolation V1 to V2 Functional 100 - - VDC Isolation Output to Earth Basic (1x MoPP) 1500 - - VAC
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2020 Bel Power Solutions & Protection BCD.01062_A PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT Operating Temperature Range PS starts up at -30 °C See graphs above for output power de-rating against TAmb and VIn. -20 - 70 °C Storage Temperature Range -40 - 85 °C Humidity RH, Non-condensing Operating Non-operating - - 90 Operating Altitude - - 4000 m Shock EN 60068-2-27 Operating: Half sine, 30 g, 18 ms, 3 axes, 6x each (3 positive and 3 negative). Non-Operating: Half sine, 50 g, 11 ms, 3 axes, 6x each (3 positive and 3 negative). Vibration EN 60068-2-64 Operating: Sine,10 – 500 Hz, 1 g, 3 axes, 1 oct/min., 60 min. Random, 5 – 500 Hz, 0.02 g2/Hz, 1 gRMS, 3 axes, 30 min. Non-Operating: 5 – 500 Hz, 2.46 gRMS (0.0122 g2/Hz), 3 axes, 30 min. MTBF Full Load, 120 VAC, 50 °C ambient 70% Duty cycle, Telcordia Issue 1 400000 - - Hours Cooling Convection with or without heat sink and conduction providing an adequate thermal path between the unit and the external environment. Case hot spot temperature, Tc, should not exceed 90 °C in any working condition. Useful Life Low line range, 200 W, 40 °C ambient, natural convention. - 4 - Years PARAMETER DESCRIPTION / CONDITION STANDARD PERFORMANCE CLASS Conducted 115 VRMS, 230 VRMS. Maximum load. 4 dB minimum margin EN 55022 (ITE) EN 55011 (ISM) EN 60601-1-2 (Medical) B Radiated At 10 m distance EN 55022 (ITE) EN 55011 (ISM) EN 60601-1-2 (Medical) B Line Voltage Fluctuation and Flicker At 20%, 50% and 100% maximum load. Nominal input voltages. EN 61000-3-3 Harmonic Current Emission Nominal input voltages. Output load > 50 W. EN 61000-3-2 C
8 ABS/MBS400 Series
tech.support@psbel.com PARAMETER DESCRIPTION / CONDITION STANDARD TEST LEVEL CRITERIA Reference standard for the medical version EN 60601-1-2 ESD 15 kV air discharge, 8 kV contact, at any point of the system. EN 61000-4-2 4 A Radiated Field 3 V/m, 80-1000 MHz, 1 KHz/2 Hz 80% AM. Dwell time is 3 sec for 2 Hz modulation Dwell time is 1 sec for 1KHz modulation EN 61000-4-3 3 A Electric Fast Transient ±2 kV on AC power port for 1 minute; ±1 kV on signal/control lines EN 61000-4-4 3 A Surge ± 2kV line to line; ± 4 KV line to earth; on AC power port; ±0.5 kV for outdoor cables EN 61000-4-5 3 A B Conducted RF Immunity 3 VRMS, 0,15-80 MHz, 1 KHz/2 Hz 80% AM EN 61000-4-6 3 A Dips and Interruptions Dip to 30% for 5 cycle (10 ms) Dip to 40% for 5 cycles (100 ms) Dip to 70% for 25 cycles (500 ms) Drop-out to 5% for 10 ms Interrupts > 95% for 5 s EN61000-4-11 EN61000-4-11 EN61000-4-11 EN61000-4-11 EN61000-4-11 A B B B B CERTIFICATION BODY SAFETY STANDARDS CATEGORY CSA/UL CSA C22.2 No. 60950-1, UL 60950-1; 2007, 2nd edition CSA C22.2 No.601.1, ANSI/AAMI ES60601-1 3rd edition Information Technology Equipment Medical IEC IECEE CB Certification IEC/EN 60950-1 2nd edition IEC/EN 60601-1 3rd edition Information Technology Equipment Medical CE Low Voltage Directive (LDV) 2006/95/EC Low Voltage Directive (LDV) 2007/47/EC MDD Information Technology Equipment Medical CONNECTIONS WIRES GAUGE AND LENGTH ASSIGNMENT COLOUR/PIN AC Input 3x 18 AWG, black external insulation, 300 V, 105°C, UL2517 cord, 310 ± 10 mm extension from grommet. Live (L) Brown Neutral (N) Blue Protective Earth (PE) Green Yellow DC Output
12 V version:
6 x 14 AWG, Style 1015, 600 V, 105°C, 260±10 mm 24, 48 V versions: 4x 14 AWG, Style 1015, 600 V, 105°C, 260±10 mm 3x (2x) +V1 Output (+V1) Red 3x (2x) V1 Return (RTN) Black Auxiliary Voltages Control Signals Wires: 8x 22 AWG, black external insulation, 300 V, 105°C, UL2517 cord, 220 ± 10 mm extension from grommet to connector. Housed by Connector: Molex 90142-0008 Terminals: Molex 90119-0109 (Tin plating) Mates with Molex 90130-1106 or equivalent. Terminals: Tin plating termination +5 V Stand-by Output (+5VSB) Red / 1 Output Power Good (P_OK) Green / 2 - Fan Voltage (-V2) Brown / 3 Remote On/Off (PS_ON) Grey / 4 + Terminal Remote Sense (+RS) Yellow / 5 Stand-by/Signals Return (RTN) Blue / 6 + Fan Voltage (+V2) White / 7 Stand-by/Signals Return (RTN) Black / 8
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2020 Bel Power Solutions & Protection BCD.01062_A PARAMETER DESCRIPTION / CONDITION Weight 1300 g (2.87 lb) – without heatsink 1665 g (3.67 lb) – with heatsink NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.