DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 12

Technical content

DESCRIPTION

High Accuracy Silicon Ceramic (HSC) Series is a piezoresistive silicon pressure sensor offering a digital output for reading pressure over the specified full scale pressure span and temperature range. The HSC Series is fully calibrated and temperature compensated for sensor offset, sensitivity, temperature effects, and non-linearity using an on-board Application Specific Integrated Circuit (ASIC). Calibrated output values for pressure are updated at approximately 2 kHz. The HSC Series is calibrated over the temperature range of 0 °C to 50 °C [32 °F to 122 °F]. The sensor is characterized for operation from a single power supply of either 3.3 Vdc or 5.0 Vdc. These sensors measure absolute, differential, and gage pressures. The absolute versions have an internal vacuum reference and an output value proportional to absolute pressure. Differential versions allow application of pressure to either side of the sensing diaphragm. Gage versions are referenced to atmospheric pressure and provide an output proportional to pressure variations from atmosphere. The TruStability pressure sensors are intended for use with non-corrosive, non-ionic gases, such as air and other dry gases. An available option extends the performance of these sensors to non-corrosive, non-ionic liquids. All products are designed and manufactured according to ISO 9001 standards.

FEATURES

Industry-leading long-term stability Extremely tight accuracy of 0.25% FSS BFSL (Full Scale Span Best Fit Straight Line) Total error band of 1% full scale span maximum Modular and flexible design offers customers a variety of package styles and options, all with the same industry- leading performance specifications Miniature 10 mm x 10 mm [0.39 in x 0.39 in] package Low operating voltage Extremely low power consumption I C- or SPI-compatible 14-bit digital output (min. 12-bit sensor resolution) Precision ASIC conditioning and temperature compensated over 0 C to 50 C [32 F to 122 F] temperature range RoHS compliant Virtually insensitive to mounting orientation Internal diagnostic functions increase system reliability Also available with analog output Absolute, differential and gage types Pressure ranges from 1 psi to 150 psi (60 mbar to 10 bar) Custom calibration available Various pressure port options Liquid media option

Table 1. Absolute Maximum Ratings Table 2. Operating Specifications

3.3 Vdc

5.0 Vdc

Sensors are either 3.3 Vdc or 5.0 Vdc based on listing selected.

5.25 Vdc

3.3 Vdc supply

5.0 Vdc supply

Table 3. Environmental Specifications Table 4. Wetted Materials

  1. Absolute maximum ratings are the extreme limits the device will withstand without damage.
  2. Ratiometricity of the sensor (the ability of the digital device to maintain performance parameters independent of supply voltage) is achieved

within the specified operating voltage for each option.

  1. The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.
  2. The compensated temperature range is the temperature range over which the sensor will produce an output proportional to pressure within

the specified performance limits.

  1. The operating temperature range is the temperature range over which the sensor will produce an output proportional to pressure but may not

remain within the specified performance limits.

  1. Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at

25 °C [77 °F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.

  1. Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range.

effect on span, and thermal hysteresis.

  1. Full Scale Span (FSS) is the algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of
  2. Life may vary depending on specific application in which sensor is utilized.
  3. Contact Honeywell Customer Service for detailed material information.

Ensure liquid media is applied to Port 1 only; Port 2 is not compatible with liquids. inside the sensor, causing damage or affecting sensor output. enter and settle within the pressure sensor if it is in this position. dead-ended sensor is difficult and has limited effectiveness for removing residue. Failure to comply with these instructions may result in product damage.

Figure 1. Nomenclature and Order Guide transfer functions are available. Contact Honeywell Customer Service for more information.

  1. Analog output is also available. Contact Honeywell Customer Service for more information.
  2. Custom pressure ranges are available. Contact Honeywell Customer Service for more information.
  3. See Table 5 for an explanation of sensor pressure types.
  4. See CAUTION on previous page.

Figure 2. Transfer Function Limits Figure 3. Completed Catalog Listing Example Table 5. Pressure Types Absolute Output is proportional to the difference between applied pressure and a built-in reference to vacuum. Pmin. is set at absolute zero pressure (full vacuum). 50% point of transfer function set at Port 1 = Port 2. pressure. Pmin. is set at atmospheric pressure. Table 6. Sensor Output at Significant Percentages Table 7. Pressure Range Specifications for 1 psi to 150 psi

Table 8. Pressure Range Specifications for 60 mbar to 10 bar

  1. Overpressure: The maximum pressure which may safely be applied to the product for it to remain in specification once pressure is returned to

applies to all available pressure ports at any temperature with the operating temperature range.

  1. Burst pressure: The maximum pressure that may be applied to any port of the product without causing escape of pressure media. Product

should not be expected to function after exposure to any pressure beyond the burst pressure.

  1. Common mode pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without

causing changes in specified performance. Table 9. Pinout for SMT and DIP Packages Table 10. Pinout for SIP Package

Figure 4. DIP Pressure Port Dimensional Drawings (For reference only: mm [in])

Figure 5. SMT Pressure Port Dimensional Drawings (For reference only: mm [in])

Figure 6. SIP Package Dimensional Drawings (For reference only: mm [in])

Figure 6. SIP Package Dimensional Drawings (continued)

1985 Douglas Drive North

Golden Valley, MN 55422 www.honeywell.com 008214-2-EN IL50 GLO Printed in USA March 2011 © 2011 Honeywell International Inc. WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. WARNING MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. DO NOT USE this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com Internet: www.honeywell.com/sensing Phone and Fax: Asia Pacific +65 6355-2828; +65 6445-3033 Fax Europe +44 (0) 1698 481481; +44 (0) 1698 481676 Fax Latin America +1-305-805-8188; +1-305-883-8257 Fax USA/Canada +1-800-537-6945; +1-815-235-6847 +1-815-235-6545 Fax