Features
Single Phase: .05 - .250 kVA
- UL Listed/NEMA Type 3R non encapsulated enclosure for indoor and outdoor service
- Low temperature rise, UL Class 130oC insulation system, 80oC temperature rise under full load
- Conduit knockouts for side entry into wiring compartment
- Copper lead wire terminations Single Phase: 0.500 - 25 kVA Three Phase: 3 - 45 kVA
- UL Listed/NEMA Type 3R encapsulated enclosure for indoor and outdoor service
- Electrostatically shielded for quality power on sizes 1 kVA and larger
- UL Class 200 oC insulation system, 115°C temperature rise under full load
- Conduit knockouts for side entry into wiring compartment
- Copper lead wire terminations
- .500 - 45 kVA units are encapsulated with electrical grade silica and epoxy for industrial applications
Related Products
- Some SolaHD DC power supplies are available with Class I, Division 2 ratings or encapsulation.
- Surge Protective Devices Certifications and Compliances Listed: E25872, E77014 - UL 1561 or UL 506 - CSA C22.2 No. 47 or No. 66 Accessories and Optional Design Styles
- Stainless Steel Enclosures
- Copper Wound designs
- UL Listed/NEMA Type 4, 4X or 12 Encapsulated Enclosures
- Low temperature designs available E25872 E77014
5Non-Ventilated Automation Transformers Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 225 Selection Table: Single Phase Group 2: 600 Volt Primary, 120/240 Secondary, 60 Hz kVA Catalog Number Group 1 Rolled Steel Catalog Number Group 2 Stainless Steel Height in (mm) Width in (mm) Depth in (mm) Approx. Ship Weight lbs (kg) Design Style * Elec Conn * Primary Amps Secondary Amps Non-Encapsulated .100 HS10B100 N/A Encapsulated * Note: Design Styles and Electrical Connections can be found at the end of the Non-Ventilated Distribution Transformers section. kVA Catalog Number Group I Rolled Steel Catalog Number Group II Stainless Steel Height in (mm) Width in (mm) Depth in (mm) Approx. Ship Weight lbs (kg) Design Style * Elec Conn * Primary Amps Secondary Amps Non-Encapsulated .050 HS1B50 N/A Encapsulated Group 1: 240 x 480 Primary, 120/240 Secondary, 60 Hz
5 Non-Ventilated Automation Transformers
Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 226 Group 4: Export 190/200/208/220/380/400/415/440 Volt Primary, 110/220 Secondary, 50/60 Hz Copper wound Export 200/208/230/400/415/460 Volt Primary, 115/230 Secondary, 50/60 Hz Copper wound Export 208/240/415/480 Volt Primary, 120/240 Secondary, 60 Hz only Copper wound kVA Catalog Number Group 1 Rolled Steel Catalog Number Group 2 Stainless Steel Height in (mm) Width in (mm) Depth in (mm) Approx. Ship Weight lbs (kg) Design Style 1 Elec Conn 1 Primary Amps 2 Secondary Amps Encapsulated, Copper Wound Selection Table: Single Phase Group 3: 120/208/240/277 Volt Primary, 120/240 Secondary, 60 Hz kVA Catalog Number Group 1 Rolled Steel Catalog Number Group 2 Stainless Steel Height in (mm) Width in (mm) Depth in (mm) Approx. Ship Weight lbs (kg) Design Style 1 Elec Conn 1 Primary Amps @ 277 V Secondary Amps Encapsulated Notes: 1. Design Styles and Electrical Connections can be found at the end of the Non-Ventilated Distribution Transformers section. 2. Amperage calculated at 220/440 Volts on primary. UL Listed and CSA Certified. 240 & 480 V not available at 50 Hz.
Group A: 480 Volt Δ Primary, 208Y/120 Secondary, 60 Hz kVA Catalog Number Group I Rolled Steel Catalog Number Group II Stainless Steel Height in (mm) Width in (mm) Depth in (mm) Approx. Ship Weight lbs (kg) Design Style 1 Elec Conn 1 Primary Amps Secondary Amps 5Non-Ventilated Automation Transformers Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 227 Group C: 480 Volt Δ Primary, 240 Volt Δ 120 Secondary with reduced capacity center tap, 60 Hz 2 kVA Catalog Number Group I Rolled Steel Catalog Number Group II Stainless Steel Height in (mm) Width in (mm) Depth in (mm) Approx. Ship Weight lbs (kg) Design Style 1 Elec Conn 1 Primary Amps Secondary Amps Notes: 1. Design Styles and Electrical Connections can be found at the end of the Non-Ventilated Distribution Transformers section. 2. Refer to Capacity of Center Tap in Center Tap Delta Transformers at the beginning of this section. Group D: 240 Volt Δ Primary, 208Y/120 Secondary, 60 Hz kVA Catalog Number Group I Rolled Steel Catalog Number Group II Stainless Steel Height in (mm) Width in (mm) Depth in (mm) Approx. Ship Weight lbs (kg) Design Style 1 Elec Conn 1 Primary Amps Secondary Amps Selection Tables: Three Phase Group B: 208 Volt Δ Primary, 208Y/120 Secondary, 60 Hz kVA Catalog Number Group I Rolled Steel Catalog Number Group II Stainless Steel Height in (mm) Width in (mm) Depth in (mm) Approx. Ship Weight lbs (kg) Design Style 1 Elec Conn 1 Primary Amps Secondary Amps
Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 228 Group E: 480 Volt Δ Primary, 380Y/220 Secondary, 60 Hz kVA Catalog Number Group I Rolled Steel Catalog Number Group II Stainless Steel Height in (mm) Width in (mm) Depth in (mm) Approx. Ship Weight lbs (kg) Design Style * Elec Conn * Primary Amps Secondary Amps Selection Tables: Three Phase Group F: 600 Volt Δ Primary, 208Y/120 Secondary, 60 Hz kVA Catalog Number Group I Rolled Steel Catalog Number Group II Stainless Steel Height in (mm) Width in (mm) Depth in (mm) Approx. Ship Weight lbs (kg) Design Style * Elec Conn * Primary Amps Secondary Amps Group G: 208 Volt Δ Primary, 480Y/277 Secondary, 60 Hz kVA Catalog Number Group I Rolled Steel Catalog Number Group II Stainless Steel Height in (mm) Width in (mm) Depth in (mm) Ship Weight Approx. (lbs) Design Style * Elec Conn * Primary Amps Secondary Amps Group H: 240 Volt Δ Primary, 480Y/277 Secondary, 60 Hz kVA Catalog Number Group I Rolled Steel Catalog Number Group II Stainless Steel Height in (mm) Width in (mm) Depth in (mm) Ship Weight Approx. (lbs) Design Style * Elec Conn * Primary Amps Secondary Amps * Notes: Design Styles and Electrical Connections can be found at the end of the Non-Ventilated Distribution Transformers section.
5Non-Ventilated Automation Transformers Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 229 Style 3 - Encapsulated Style 4 - Encapsulated Style 2 - Non-Encapsulated Customized Enclosures - Contact Technical Services Style 5 - Encapsulated Available for all encapsulated kVA sizes (For Type 4, 12 and 4X) Design Styles W D H W D H
Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 230 Primary Voltage Interconnect Connect Lines to
277 H2 to H3 H1 & H6
240 H2 to H3 H1 & H5
208 H2 to H3 H1 & H4
120 H1 to H3
H2 to H5 H1 & H5 Secondary Voltage Interconnect Connect Lines to
240 X2 to X3 X1 & X4
120 X1 to X3
X2 to X4 X1 & X4 HS12 Series (1 kVA only) Primary Voltage Interconnect Connect Lines to
277 H4 to H5 H1 & H8
240 H3 to H6 H1 & H8
208 H2 to H7 H1 & H8
120 H1 to H6
H3 to H8 H1 & H8 Secondary Voltage Interconnect Connect Lines to X2 to X4 X1 & X4 HS12 Series Primary Voltage Interconnect Connect Lines to
504 H4 to H5 H1 & H8
492 H3 to H5 H1 & H8
480 H3 to H6 H1 & H8
468 H2 to H6 H1 & H8
456 H2 to H7 H1 & H8
252 H1 to H5
H4 to H8 H1 & H8
240 H1 to H6
H3 to H8 H1 & H8
228 H1 to H7
H2 to H8 H1 & H8 Secondary Voltage Interconnect Connect Lines to X2 to X4 X1 & X4 HS5 Series Primary Voltage Interconnect Connect Lines to
480 H2 to H3 H1 & H4
240 H1 to H3
H2 to H4 H1 & H4 Secondary Voltage Interconnect Connect Lines to X2 to X4 X1 & X4 HS1 Series Primary Voltage Interconnect Connect Lines to
504 H5 to H6 H1 & H10
492 H4 to H6 H1 & H10
480 H4 to H7 H1 & H10
468 H3 to H7 H1 & H10
456 H3 to H8 H1 & H10
444 H2 to H8 H1 & H10
432 H2 to H9 H1 & H10
252 H1 to H6
H5 to H10 H1 & H10
240 H1 to H7
H4 to H10 H1 & H10
228 H1 to H8
H3 to H10 H1 & H10
216 H1 to H9
H2 to H10 H1 & H10 Secondary Voltage Interconnect Connect Lines to X2 to X4 X1 & X4 HS5 Series Primary Voltage Interconnect Connect Lines to H2 to H4 H1 & H4 Secondary Voltage Interconnect Connect Lines to X2 to X4 X1 & X4 HS1 Series Electrical Connections (Single Phase)
240 X 480 Volt Primary
Taps: None 15 17 Taps: None Taps: 2, 2½% FCAN & FCBN
240 X 480 Volt Primary,
Taps: 2, 2½% FCAN; 4, 2½% FCBN 120/208/240/277 Volt Primary 120/240 Volt Secondary Taps: None 120/208/240/277 Volt Primary 120/240 Volt Secondary Taps: None Note: Connect the electrostatic shield to the equipment ground (green) or to both the equipment ground and the system ground (white). Specifications are subject to change without notice. = Earth Ground H1 H2H3 H4 X1 X3 X2 X4 SHIELD H1 H2 H3 H4 H5 H6H7 H8 SHIELD X1 X3 X2 X4 H1 H2H3 H4 X1 X3 X2 X4 H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 SHIELD X1 X3 X2 X4 H1 H2H3 H4 H5 H6 SHIELD X1 X3 X2 X4 H1 H2 H3 H4 H5 H6 H7 H8 SHIELD X1 X3 X2 X4
5Non-Ventilated Automation Transformers Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 231 Primary Voltage Interconnect Connect Lines to
600 H1 & H2
Secondary Voltage Interconnect Connect Lines to X2 to m X1, X2 & X4 X2 to X4 X1 & X4 HS10 Series Primary Voltage Interconnect Connect Lines to
440 H5 to H6 H1 & H10
415 H4 to H7 H1 & H10
400 H3 to H8 H1 & H10
380 H2 to H9 H1 & H10
220 H1 to H6,
H5 to H10 H1 & H10
208 H1 to H7,
H4 to H10 H1 & H10
200 H1 to H8,
H3 to H10 H1 & H10
190 H1 to H9
H2 to H10 H1 & H10 Secondary Voltage Interconnect Connect Lines to
220 X2 to X3 X1 & X4
X2 to X1, X2 & X4
110 X1 to X3
X2 to X4 X1 & X4 HS14 Series Primary Voltage Interconnect Connect Lines to
415 H4 to H6 H1 & H9
400 H3 to H6 H1 & H8
380 H2 to H6 H1 & H7
220 H1 to H6
H5 to H10 H1 & H10
208 H1 to H6
H4 to H9 H1 & H9
200 H1 to H6
H3 to H8 H1 & H8
190 H1 to H6
H2 to H7 H1 & H7 Secondary Voltage Interconnect Connect Lines to X2 to X1, X2 & X4 X2 to X4 X1 & X4 HS14 Series (1 kVA only) Primary Voltage Interconnect Connect Lines to
600 H3 to H4 H1 & H6
570 H2 to H4 H1 & H6
540 H2 to H5 H1 & H6
Secondary Voltage Interconnect Connect Lines to X2 to X4 X1 & X4 HS10 Series
600 Volt Primary
Taps: 2, 5% FCBN Electrical Connections (Single Phase) 190/200/208/220/380/400/415/440 Volt Pri. 110/220 Volt Secondary Taps: None 190/200/208/220/380/400/415/440 Volt Pri. 110/220 Volt Secondary Taps: None
600 Volt Primary,
Taps: None Note: 1 through 2 kVA units have electrostatic shielding. Note: Connect the electrostatic shield to the equipment ground (green) or to both the equipment ground and the system ground (white). Specifications are subject to change without notice. = Earth Ground 232221 H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 SHIELD X1 X3 X2 X4 X1 X3 X2 X4 H1 H2 H1 H2 H3 H4 H5 H6 SHIELD X1 X3 X2 X4 H1 H6H2 H7H3 H8H4 H9H5 H10 SHIELD X1 X3 X2 X4
Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 232 Primary Voltage Interconnect Connect Lines to 480 1-H1 & 2-H2 & 3-H3 H1, H2 & H3 456 4-H1 & 5-H2 & 6-H3 H1, H2 & H3 432 7-H1 & 8-H2 & 9-H3 H1, H2 & H3 Secondary Voltage Interconnect Connect Lines to
380 X1, X2, X3
220 X0, X1, X2, X3
480 1-H1 & 2-H2 & 3-H3 H1, H2, H3 456 4-H1 & 5-H2 & 6-H3 H1, H2, H3 432 7-H1 & 8-H2 & 9-H3 H1, H2, H3 Secondary Voltage Interconnect Connect Lines To
240 X1, X2, X3
Voltage Interconnect Connect Lines to 480 1-H1 & 2-H2 & 3- H3 H1, H2, H3 456 4-H1 & 5-H2 & 6- H3 H1, H2, H3 432 7-H1 & 8-H2 & 9- H3 H1, H2, H3 Secondary Voltage Connect Lines to
208 X1, X2, & X3
120 X0, X1, X2, X3
480 Δ Volt Primary 208Y/120 Volt Secondary Taps: 2, 5% FCBN27 Electrical Connections (Three Phase) 480 Δ Volt Primary 240 Δ w/120 CT Volt Secondary Taps: 2, 5% FCBN 480 Δ Volt Primary 380Y/220 Volt Secondary Taps: 2, 5% FCBN Primary Voltage Connect Taps Connect Lines To 208 1-H1 & 2-H2 & 3-H3 H1, H2, H3 198 4-H1 & 5-H2 & 6-H3 H1, H2, H3 187 7-H1 & 8-H2 & 9-H3 H1, H2, H3 Secondary Voltage Connect Lines To 208 Δ Volt Primary 208Y/120 Volt Secondary Taps: 2, 5% FCBN 26 27 Notes: Connect the electrostatic shield to the equipment ground (green) or to both the equipment ground and the system ground (white). Specifications are subject to change without notice. = Earth Ground X1 X2 X3X0 SHIELD H1 H3H2 4 5 61 2 37 8 9 H1 H3 X1 X2 X3X0 SHIELD H1 H3H2 4 5 61 2 37 8 9 H1 H3 X1 X2 X3X0 SHIELD H1 H3H2 4 5 61 2 37 8 9 H1 H3 X1 X2 X3X6 SHIELD H1 H3H2 4 5 61 2 37 8 9 H1 H3 Primary Voltage Connect Taps Connect Lines To 240 1-H1 & 2-H2 & 3-H3 H1, H2, H3 228 4-H1 & 5-H2 & 6-H3 H1, H2, H3 216 7-H1 & 8-H2 & 9-H3 H1, H2, H3 Secondary Voltage Connect Lines To 240 Δ Volt Primary 208Y/120 Volt Secondary Taps: 2, 5% FCBN X1 X2 X3X0 SHIELD H1 H3H2 4 5 61 2 37 8 9 H1 H3
5Non-Ventilated Automation Transformers Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 233 Electrical Connections (Three Phase) Primary Voltage Connect Taps Line Leads 208 1-X1 & 2-X2 & 3-X3 X1, X2, X3 198 4-X1 & 5-X2 & 6-X3 X1, X2, X3 187 7-X1 & 8-X2 & 9-X3 X1, X2, X3 Secondary Voltage Line Leads
480 H1, H2, H3
277 H0, H1, H2, H3
208 Δ Volt Primary 480Y/277 Volt Secondary Taps: 2, 5% FCBN Primary Voltage Connect Taps Line Leads 240 1-X1 & 2-X2 & 3-X3 X1, X2, X3 228 4-X1 & 5-X2 & 6-X3 X1, X2, X3 216 7-X1 & 8-X2 & 9-X3 X1, X2, X3 Secondary Voltage Line Leads Notes: Connect the electrostatic shield to the equipment ground (green) or to both the equipment ground and the system ground (white). Specifications are subject to change without notice. 240 Δ Volt Primary 480Y/277 Volt Secondary Taps: 2, 5% FCBN H1 H2 H3H0 SHIELD X1 X3X2 4 5 61 2 37 8 9 X1 X3 H1 H2 H3H0 SHIELD X1 X3X2 4 5 61 2 37 8 9 X1 X3 Primary Voltage Connect Taps Line Leads 600 1-H1 & 2-H2 & 3-H3 H1, H2, H3 570 4-H1 & 5-H2 & 6-H3 H1, H2, H3 540 7-H1 & 8-H2 & 9-H3 H1, H2, H3 Secondary Voltage Line Leads
208 X1, X2, X3
600 Δ Volt Primary 208Y/120 Volt Secondary Taps: 2, 5% FCBN X1 X2 X3X0 SHIELD H1 H3H2 4 5 61 2 37 8 9 H1 H3