File Name:HRP-300N3-SPEC 2022-03-03 300W Ultra-High Peak Power Supply HRP- 3 0 0 N3 seri es TPTC004 IEC62368-1BS EN/EN62368-1 Bauar Sicherheit egel gema t gepruft od be www. ID 2000000000 tuv.com wac g o s AS/NZS 62368.1 User’s Manual
HRP-300N3-24 HRP-300N3-36 HRP-300N3-48MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max.) Note.2 OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE Note.4 FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.)INPUT ENVIRONMENT INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER TEMPERATURE SAFETY STANDARDS SAFETY & EMC (Note 6) WITHSTAND VOLTAGE ISOLATION RESISTANCE WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MTBF DIMENSIONOTHERS NOTE PACKING OVERLOAD OVER VOLTAGE PROTECTION AC CURRENT (Typ.) 24V 36V 48V 14A 9A 7A 0 ~ 14A 0 ~ 9A 0 ~ 7A 336W 324W 336W 150mVp-p 250mVp-p 250mVp-p ±1.0% ±1.0% ±1.0% ±0.2% ±0.2% ±0.2% ±0.5% ±0.5% ±0.5% 1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load 16ms/230VAC 16ms/115VAC at full load 85 ~ 264VAC 120 ~ 370VDC 47 ~ 63Hz PF>0.95/230VAC PF>0.99/115VAC at full load 3.5A/115VAC 1.8A/230VAC 35A/115VAC 75A/230VAC <2mA / 240VAC Protection type : Shut down o/p voltage, re-power on to recover TSW1:Shut down o/p voltage, recovers automatically after temperature goes down RTH3: Shut down o/p voltage, re-power on to recover UL62368-1, TUV BS EN/EN62368-1, , AS/NZS 62368.1 approvedEAC TP TC 004 I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH -40 ~ +70℃ (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85℃, 10 ~ 95% RH non-condensing ±0.03%/℃ (0 ~ 50℃) 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes 199*105*41mm (L*W*H) 0.9Kg;15pcs/14.5Kg/0.84CUFT 87% 88% 89% DC OK SIGNAL PSU turns on : 3.3 ~ 5.6V ; PSU turns off : 0 ~ 1V FUNCTION FAN CONTROL (Typ.) Load 35±15% or RTH2≧50℃ Fan on 1524.0K hrs min. Telcordia TR/SR-332 (Bellcore) ; 187.7K hrs min. MIL-HDBK-217F (25℃) 300W Ultra-High Peak Power Supply HRP- 3 0 0 N3 seri es Parameter Conducted Radiated Voltage Flicker Standard BS EN/EN55032 BS EN/EN55032 BS EN/EN61000-3-3 Test Level / Note Class B Class B ----- EMC IMMUNITY EMC EMISSION BS EN/EN55035 , BS EN/EN61000-6-2(BS EN/EN50082-2) Parameter ESD RF field EFT/ Burst Surge Conducted Magnetic Field Voltage Dips and Interruptions Standard BS EN/EN61000-4-2 BS EN/EN61000-4-3 BS EN/EN61000-4-4 BS EN/EN61000-4-5 BS EN/EN61000-4-6 BS EN/EN61000-4-8 BS EN/EN61000-4-11 Test Level / Note Level 3, 8KV air; Level 2, 4KV contact Level 3, 10V/m Level 3, 2KV Level 4, 4KV/Line-FG; 2KV/Line-Line Level 3, 10V Level 4, 30A/m 95% dip 0.5 periods, 30% dip 25 periods, 95% interruptions 250 periods BS EN/EN61000-3-2Harmonic current File Name:HRP-300N3-SPEC 2022-03-03 Class A Output power >105% rated for more than 5 seconds then shut down o/p voltage, re-power on to recover Constant current limiting for output power >380%(1140W) rated for more than 5 seconds and then shut down o/p voltage, re-power on to recover 5000 metersOPERATING ALTITUDE Note.5 HRP-300N3-12 12V 27A 0 ~ 27A 324W 120mVp-p 10.2 ~ 13.8V ±1.0% ±0.3% ±0.5% 14.4 ~ 16.8V 88%
300W Ultra-High Peak Power Supply Derating Curve Output Derating VS Input Voltage INPUT VOLTAGE (V) 60Hz 85 100 125 135 155 264 100 LOAD(%) Block Diagram PWM fosc : 70KHz EMI INRUSH ACTIVE FILTER CURRENT LIMITING RECTIFIERS PFC I/P FG PWMPFC CIRCUIT DETECTION POWER SWITCHING FILTER RECTIFIERS +V CONTROLCONTROL O.V.P. DC OK HRP- 3 0 0 N3 seri es AMBIENT TEMPERATURE (℃) LOAD (%) -40 0-10 10 20 30 40 50 60 (HORIZONTAL) 100 Normal load only File Name:HRP-300N3-SPEC 2022-03-03
300W Ultra-High Peak Power Supply HRP- 3 0 0 N3 seri es P =av P pk x t + P npk x (T-t) T ≤ P rated Duty = t T ≤ 35%x 100% ≤ 5sect P av : Averageoutputpower(W) P pk : Peakoutputpower(W) P npk : Non-peakoutputpower(W) P rated : Ratedoutputpower(W) t : Peakpowerwidth(sec) T : Period(sec) P pk P av P npk t T File Name:HRP-300N3-SPEC 2022-03-03 1.Peak Power Peak output power (W) For example (24V model) : Vin = 200V Duty_max = 10% P = P = 336Wav rated P = 800W pk t≤ 5 sec Function Manual 5 sec 10% T 50 sec ≧ ≧ 200Vac 100Vac Duty(%) 300 500 600 900 1100400 700 800 1000 1200 T P -av t P pk T-t P ≤ npk P ≤ 284.4W npk
300W Ultra-High Peak Power Supply HRP- 3 0 0 N3 seri es File Name:HRP-300N3-SPEC 2022-03-03 The remote sensing compensates voltage drop on the load wiring up to 0.5V. 2.Remote Sense Fig 1.1 1 7 2 8 CN100 Sense lines should be twisted in pairs NC NC DC-OK GND NC NC 1 2 3 4 5 6 7 CN100 LOAD - + (Pin7) (Pin8) 1 7 2 8 CN100 NC NC DC-OK GND NC NC Between DC-OK(pin3) and GND(pin5) 3.3 ~ 5.6V 0 ~ 1V Output Status ON OFF 3.DC-OK Signal DC-OK signal is a TTL level signal. High when PSU turns on. 1 2 3 4 5 6 7 CN100 Fig 2.1
Case No.980A Unit:mm 300W Ultra-High Peak Power Supply HRP- 3 0 0 N3 seri es Terminal Pin No. Assignment Pin No. Pin No. 4,5 6,7 Assignment Assignment DC OUTPUT -V DC OUTPUT +V FG AC/L AC/N HRS DF11-08DP-2DS or equivalent Connector Pin No. Assignment (CN100) : Pin No. 1,2,4,6 Assignment NC Mating Housing HRS DF11-8DS or equivalent Terminal HRS DF11-**SC or equivalent+S DC-OK GND 1812.5 18 12.5 Air flow direction 17max. 167.5 4-M4 L=5 FAN 12.25 168.5 12.25 4-M4 L=6 4-M4 L=6 Installation Manual Please refer to : http://www.meanwell.com/manual.html File Name:HRP-300N3-SPEC 2022-03-03 LED CN100 SVR 119.2 168.5 199 120 12.25 42.5 125 105 7515 12.25167.5