Banner's HLS27 Hazardous Location LED Strip Light has a sturdy aluminum housing and is encased in a shatterproof, UV-stabilized, polycarbonate shell, making it ideal for harsh indoor and outdoor applications.

  • Low-profile, space-saving design for use in hazardous locations
  • Rugged, water-resistant IEC IP66, IEC IP67 design
  • Available in eight lengths from 145 mm to 1130 mm
  • Available in single or dual color models
  • Standard and optional 300 series stainless steel mounting brackets protect against impact
  • Single color models have the capability to dim lights using the wiring pinout (Hi/Lo/Off)
  • Pulse Width Modulation (PWM) models have the capability to control intensity from 0% to 100% using PWM on an input control wire
  • Automatic temperature protection built into the unit—above 50 °C, the light dims to manage heat and protect product lifetime
  • Certification for cULus and ATEX/IECEx, see details in specifications Models — Single Color and PWM HLS27 Connector Lighted Length (mm)LED ColorTypeFamily D = Enhanced Protection W = Cool white WW = Warm white R = Red G = Green B = Blue Y = Yellow 0145 0285 0430 0570 0710 0850 0990 1130 Blank = 2 m ITC-ER 3-wire cable with unterminated tinned leads D W 0145 Window C = Clear C Blank = Hi/Lo/Off PWM = Pulse width modulation dimming Control Type Protection Suitable for ATEX / IECEx Suitable for NEC & CEC D Enhanced Protection Gas Zone: 2 Dust Zone: 22 Gas Zone: 2 Dust Zone: 22 Class I Division 2 Class II Division 2 Class III Division 1 and 2 Models — Dual Color HLS27 Connector Lighted Length (mm)C1TypeFamily D = Enhanced Protection W = Daylight white R = Red G = Green B = Blue Y = Yellow 0145 0285 0430 0570 0710 0850 0990 1130 Blank = 2 m ITC-ER 3-wire cable with unterminated tinned leads D W 0145 Window C = Clear C LED Color R Type Protection Suitable for ATEX / IECEx Suitable for NEC & CEC D Enhanced Protection Gas Zone: 2 Dust Zone: 22 Gas Zone: 2 Dust Zone: 22 Class I Division 2 Class II Division 2 Class III Division 1 and 2 HLS27 Hazardous Location LED Strip Light Original Document 197949 Rev. B

3 January 2019

Hazardous Location Applications WARNING:

  • Hazardous Locations
  • It is the user's responsibility to ensure that all local, state, and national laws, rules, codes, or regulations relating to the installation and use of this device in any particular application are satisfied. This device must be installed by Qualified Persons, in accordance with this document and applicable regulations.
  • A Qualified Person is a person who, by possession of a recognized degree or certificate of professional training, or who, by extensive knowledge, training and experience, has successfully demonstrated the ability to solve problems relating to the subject matter and work. WARNING: The hazardous location mounting hardware is designed to help protect the HLS27 light from damage during impact and must be used in all hazardous location applications. Failure to use the Banner supplied mounting hardware correctly will void the hazardous location rating of the light. CAUTION:
  • Electrostatic Discharge (ESD) Special Conditions for Safe Use
  • Parts of the enclosure are non-conducting and can generate an ignition-capable level of ESD.
  • Clean the equipment with only a damp cloth. General Notes and Conditions for Safe Use:
  • See Specifications and Wiring Diagrams for important information concerning entity parameters, permissible locations, electrical connections and certifications.
  • In addition to the warning above concerning user responsibility, the installation must comply with the following: ◦ All installations must comply with all manufacturer's instructions. ▪ This device is provided with a PLTC-ER/ITC-ER cable and must be installed in accordance with the following:
  • NEC Article 501.10 (B) for Class I Division 2
  • NEC Article 502.10 (B) for Class II Division 2
  • NEC Article 503.10 (A) or (B) for Class III Division 1 or 2 respectively
  • Canadian Electrical Code (CSA C22.1) for Canadian Installations
  • Section 9 of IEC 60079-14 for ATEX/IECEx locations ▪ The PLTCER/ITC-ER cable shall be installed in accordance with the provisions of NEC Article 725 (PLTC-ER) or 727.4 (ITC- ER) for Class I Division 2, Class II Division 2, and Class III Division 1 and 2 locations ▪ The cable shall be terminated with a fitting certified for the appropriate location classification ▪ The device must be powered by a class 2 power supply
  • Do not attempt any repairs to this device; it contains no field-replaceable parts or components. Tampering and/or replacement with non- factory components may adversely affect the safe use of the system.
  • The nonconducting materials of this device may be susceptible to ignition-capable level of electrostatic charging and precautions must be taken to avoid this. The user/installer shall ensure that the equipment is not installed in a location where it may be subjected to external conditions (such as high-pressure steam) which are conducive to creating a build-up of electrostatic charges.
  • The user/installer must take suitable precautions to prevent the device from being adversely affected by aggressive substances, such as acidic liquids or gases that may attack metals, or solvents that may affect polymeric (plastic) materials. Suitable precautions include routine inspection or maintenance procedures require replacement of damaged devices or establishing from the materials data sheet that the device is resistant to specific chemicals. These precautions must ensure that the type of protection is not compromised. Wiring Diagram Wire Color Single Color Models Dual Color Models PWM Models 12–30 V dc 1 - Brown 12 V dc to 30 V dc Color 1: 12 V dc to 30 V dc 12 V dc to 30 V dc 3 - Blue dc common dc common dc common 4 - Black Connect to 12 V dc to 30 V dc for 50% intensity. For 100% intensity, leave the black wire floating or connected to common. Color 2: 12 V dc to 30 V dc (color 2 overrides color 1) Pulse width modulation (PWM) input. For maximum intensity, leave the black wire floating or connected to common. Connecting to 12 V dc to 30 V dc will cause LEDs to shut off. Mounting Instructions Multiple mounting options are available for the HLS27 in hazardous locations. In the two options listed below, the mounting brackets must be spaced a distance of (L4) apart to ensure the device meets impact protection standards for hazardous locations. Included Mounting Hardware (LMBHLS27S – 2 Brackets) When using the standard mounting hardware, the mounting hole centers for each individual bracket must be spaced 50.0 mm (1.97 inches) from one another. This spacing is critical for the bracket to provide the required impact protection and prevent rotation of the light within the bracket. The stainless-steel bracket is designed to be used with M5 or #10 stainless-steel hardware. HLS27 Hazardous Location LED Strip Light 2 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 197949 Rev. B

12 V dc to 30 V dc

Use only with suitable Class 2 power supply Light Length Typical Current Max. Current

12 V dc 24 V dc 30 V dc A

145 mm 0.33 A 0.15 A 0.12 A 0.4 285 mm 0.66 A 0.30 A 0.24 A 0.8 430 mm 1.01 A 0.46 A 0.36 A 1.2 570 mm 1.36 A 0.61 A 0.48 A 1.6 710 mm 1.75 A 0.77 A 0.60 A 2.0 850 mm 2.13 A 0.92 A 0.73 A 2.4 990 mm 2.59 A 1.08 A 0.85 A 2.8 1130 mm 3.04 A 1.24 A 0.97 A 3.2 Environmental Rating IEC IP66, IEC IP67 Supply Protection Circuitry Protected against reverse polarity and transient voltages Pulse Width Modulation (PWM Models Only) Frequency: Up to 1000 Hz Voltage: 8 V dc to 30 V dc Current: 4 mA maximum per foot LED Lifetime Lumen Maintenance - L70 When operating within specifications, output will decrease less than 30% after 50,000 hours Construction Clear anodized aluminum housing; UV stabilized polycarbonate outer housing Mounting Bracket kit LMBHLS27S included (2 brackets for use with HLS27 Hazardous Location LED Strip Light) Optional bracket kit LMBHLS27O (2 brackets and hardware for use with HLS27 Hazardous Location LED Strip Light) Connections 2 m (6.3 ft) long, 6.3 mm (0.25 inch) diameter ITC-ER cable with unterminated leads; pressured EX60 jacket (type ST2 per IEC 60092-360:2014), paper separator, filler as needed, compliant with 60332-3-22; UL TC-ERDB, ITC, PLTC, ERDB, IEEE 1580-2010, ABS Operating Temperature For NEC & CEC applications: –40 °C to +60 °C (–40 °F to +140 °F) For ATEX/IECEx applications: –40 °C to +50 °C (–40 °F to +122 °F) 90% maximum relative humidity (non-condensing) Light output begins to decrease above 50 °C (122 °F) and will be approximately 65% of maximum intensity of 60 °C (140 °F) Storage Temperature: –40 °C to +70 °C (–40 °F to +158 °F) Vibration and Mechanical Shock Vibration: 10 Hz to 55 Hz, 1.0 mm peak-to-peak amplitude per IEC 60068-2-6 Shock: 15G 11 ms duration, half sine wave per IEC 60068-2-27 Approvals NEC and CEC: –40°C ≤ Ta ≤ +60°C Gas & Vapors: Class I Zone 2 IIC T4 / Class I Div 2 Groups ABCD T4 Dust: Class II Zone 22 IIIC T100°C / Class II Div 2 Groups FG T5 Fibers: Class III Div 1 and Div 2 T5 ATEX/IECEX: –40°C ≤ Ta ≤ +50°C Gas & Vapors: II 3 G Ex ec IIC T4 Gc (Group IIC Zone 2) Dust: II 3 D Ex tc IIIC T85°C Dc (Group IIIC Zone 22) UL/cULus E467619 IECEx UL 18.0115X : DEMKO 18 ATEX 2122X 1725 Light Characteristics – Single Color Models Cool White Efficacy: 104 lumens/Watt typical at 24 V dc at 25 °C (77 °F) CRI: 85, typical Color Dominant Wavelength (nm) or Color Temperature Lighted Length Lumens (Typical at 25 °C) 145 mm 285 mm 430 mm 570 mm 710 mm 850 mm 990 mm 1130 mm Cool White 6500 K (+ 600 K/- 500 K) 375 750 1125 1500 1875 2250 2625 3000 Warm White 3000 K (+ 250 K/- 150 K) 375 750 1125 1500 1875 2250 2625 3000 Green 525 nm 205 410 615 820 1025 1230 1435 1640 Red 618 nm 65 130 195 260 325 390 455 520 Yellow 590 nm 55 110 165 220 275 330 385 440 Blue 460 nm 45 90 135 180 225 270 315 360 Light Characteristics – Dual Color Models Daylight White Efficacy: 76 lumens/Watt typical at 24 V dc at 25 °C (77 °F) CRI: 83, typical Color Dominant Wavelength (nm) or Color Temperature Lighted Length Lumens (Typical at 25 °C) 145 mm 285 mm 430 mm 570 mm 710 mm 850 mm 990 mm 1130 mm Daylight White 5000 K (± 300 K) 275 550 825 1100 1375 1650 1925 2200 Green 525 nm 175 350 525 700 875 1050 1225 1400 Red 625 nm 115 230 345 460 575 690 805 920 Yellow 590 nm 85 170 255 340 425 510 595 680 Blue 470 nm 65 130 195 260 325 390 455 520 HLS27 Hazardous Location LED Strip Light 4 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 197949 Rev. B

27.80[1.094] 18.53[0.73] 2X Ø 36.27 [1.428] 2X Ø 38.10 [1.5] L1L2L3 Model L1 L2 L3 Performance Optical data shown below is for standard single color cool white only. To get lux and candela values for other colors in both single and dual color versions, multiply the values shown on the charts by the following factors. Single Color: Warm White: 1.000 Green: 0.547 Red: 0.173 Yellow: 0.147 Blue: 0.120 Dual Color: Daylight White: 0.733 Green: 0.467 Red: 0.307 Yellow: 0.227 Blue: 0.173 145 mm Models 180° CD(candela) 140 117 Center Beam (lux) 3116 lux0.17 m 0.33 m 0.50 m 0.67 m 0.83 m 1.00 m Vertical Spread: 118.4° Horizontal Spread: 123.5° 0.56 m 0.62 m 1.11 m 1.24 m 1.68 m 1.86 m Mount height of 1 meter (1 m) 2.24 m 2.49 m 1002 lux 451 lux 261 lux 2.79 m3.10 m170 lux 3.35 m3.72 m126 lux Beam Width (m) 117 140 170°160°150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30°20°10°0° Polar Candela Distribution Isolux Pattern Illuminance at a Distance Vert. Horiz. 0 m 0 m 1 2 Vertical Angle: 0° Vertical 90° Horizontal 50 lux 40 lux 30 lux 20 lux 10 lux 5 lux 100 lux 75 lux 285 mm Models 180° CD(candela) 270 225 180 135 135 180 Center Beam (lux) 6101 lux0.17 m 0.33 m 0.50 m 0.67 m 0.83 m 1.00 m Vertical Spread: 118.4° Horizontal Spread: 123.5° 0.56 m 0.62 m 1.11 m 1.24 m 1.68 m 1.86 m Mount height of 1 meter (1 m) 2.24 m 2.49 m 2154 lux 1019 lux 585 lux 2.79 m3.10 m389 lux 3.35 m3.72 m276 lux Beam Width (m) 225 270 170°160°150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30°20°10°0° Polar Candela Distribution Isolux Pattern Illuminance at a Distance Vert. Horiz. 0 m 0 m 1 2 Vertical Angle: 0° Vertical 90° Horizontal 100 lux 75 lux 50 lux 25 lux 10 lux 5 lux 200 lux 150 lux HLS27 Hazardous Location LED Strip Light P/N 197949 Rev. B www.bannerengineering.com - Tel: + 1 888 373 6767 5

180° CD(candela) 400 333 267 200 133 133 200 267 Center Beam (lux) 6888 lux0.17 m 0.33 m 0.50 m 0.67 m 0.83 m 1.00 m Vertical Spread: 118.4° Horizontal Spread: 123.5° 0.56 m 0.62 m 1.11 m 1.24 m 1.68 m 1.86 m Mount height of 1 meter (1 m) 2.24 m 2.49 m 2821 lux 1458 lux 866 lux 2.79 m3.10 m592 lux 3.35 m3.72 m403 lux Beam Width (m) 333 400 170°160°150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30°20°10°0° Polar Candela Distribution Isolux Pattern Illuminance at a Distance Vert. Horiz. 0 m 0 m 1 2 Vertical Angle: 0° Vertical 90° Horizontal 300 lux 250 lux 200 lux 150 lux 100 lux 50 lux 25 lux 10 lux 570 mm Models 180° CD(candela) 530 442 353 265 177 177 265 353 Center Beam (lux) 7043 lux0.17 m 0.33 m 0.50 m 0.67 m 0.83 m 1.00 m Vertical Spread: 118.4° Horizontal Spread: 123.5° 0.56 m 0.62 m 1.11 m 1.24 m 1.68 m 1.86 m Mount height of 1 meter (1 m) 2.24 m 2.49 m 3116 lux 1668 lux 1124 lux 2.79 m3.10 m766 lux 3.35 m3.72 m545 lux Beam Width (m) 442 530 170°160°150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30°20°10°0° Polar Candela Distribution Isolux Pattern Illuminance at a Distance Vert. Horiz. 0 m 0 m 1 2 Vertical Angle: 0° Vertical 90° Horizontal 450 lux 375 lux 300 lux 225 lux 150 lux 75 lux 50 lux 25 lux 710 mm Models 180° CD(candela) 660 550 440 330 220 110 110 220 330 440 Center Beam (lux) 7199 lux0.17 m 0.33 m 0.50 m 0.67 m 0.83 m 1.00 m Vertical Spread: 118.4° Horizontal Spread: 123.5° 0.56 m 0.62 m 1.11 m 1.24 m 1.68 m 1.86 m Mount height of 1 meter (1 m) 2.24 m 2.49 m 3411 lux 1878 lux 1189 lux 2.79 m3.10 m822 lux 3.35 m3.72 m602 lux Beam Width (m) 550 660 170°160°150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30°20°10°0° Polar Candela Distribution Isolux Pattern Illuminance at a Distance Vert. Horiz. 0 m 0 m 1 2 Vertical Angle: 0° Vertical 90° Horizontal 600 lux 500 lux 400 lux 300 lux 200 lux 100 lux 50 lux 25 lux HLS27 Hazardous Location LED Strip Light 6 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 197949 Rev. B

180° CD(candela) 800 667 533 400 267 133 133 267 400 533 Center Beam (lux) 7550 lux0.17 m 0.33 m 0.50 m 0.67 m 0.83 m 1.00 m Vertical Spread: 118.4° Horizontal Spread: 123.5° 0.56 m 0.62 m 1.11 m 1.24 m 1.68 m 1.86 m Mount height of 1 meter (1 m) 2.24 m 2.49 m 3779 lux 2171 lux 1397 lux 2.79 m3.10 m980 lux 3.35 m3.72 m713 lux Beam Width (m) 667 800 170°160°150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30°20°10°0° Polar Candela Distribution Isolux Pattern Illuminance at a Distance Vert. Horiz. 0 m 0 m 1 2 Vertical Angle: 0° Vertical 90° Horizontal 700 lux 575 lux 450 lux 325 lux 200 lux 75 lux 50 lux 25 lux 990 mm Models 180° CD(candela) 930 775 620 465 310 155 155 310 465 620 Center Beam (lux) 7761 lux0.17 m 0.33 m 0.50 m 0.67 m 0.83 m 1.00 m Vertical Spread: 118.4° Horizontal Spread: 123.5° 0.56 m 0.62 m 1.11 m 1.24 m 1.68 m 1.86 m Mount height of 1 meter (1 m) 2.24 m 2.49 m 3985 lux 2351 lux 1544 lux 2.79 m3.10 m1094 lux 3.35 m3.72 m804 lux Beam Width (m) 775 930 170°160°150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30°20°10°0° Polar Candela Distribution Isolux Pattern Illuminance at a Distance Vert. Horiz. 0 m 0 m 1 2 Vertical Angle: 0° Vertical 90° Horizontal 775 lux 625 lux 475 lux 325 lux 175 lux 100 lux 50 lux 25 lux 1130 mm Models 180° CD(candela) 1100 917 733 550 367 183 183 367 550 733 Center Beam (lux) 7889 lux0.17 m 0.33 m 0.50 m 0.67 m 0.83 m 1.00 m Vertical Spread: 118.4° Horizontal Spread: 123.5° 0.56 m 0.62 m 1.11 m 1.24 m 1.68 m 1.86 m Mount height of 1 meter (1 m) 2.24 m 2.49 m 4127 lux 2498 lux 1686 lux 2.79 m3.10 m1213 lux 3.35 m3.72 m893 lux Beam Width (m) 917 1100 170°160°150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30°20°10°0° Polar Candela Distribution Isolux Pattern Illuminance at a Distance Vert. Horiz. 0 m 0 m 1 2 Vertical Angle: 0° Vertical 90° Horizontal 850 lux 700 lux 550 lux 400 lux 250 lux 100 lux 50 lux 25 lux HLS27 Hazardous Location LED Strip Light P/N 197949 Rev. B www.bannerengineering.com - Tel: + 1 888 373 6767 7

The following brackets can be used with the HLS27 Hazardous Location LED Strip Light. LMBHLS27S

  • Set of 2 brackets
  • Impact absorbing
  • 300 series stainless steel
  • Clearance for M5 or #10 hardware Ø 5.5 12.7 62 ± 118 ± 1 Ø 36 ± 1 LMBHLS27O
  • Set of 2 brackets
  • Impact absorbing clamp
  • 300 series stainless steel
  • M5 stainless steel hardware included 12.723 Ø 5.5 61.2 The following brackets can be used with the HLS27 Hazardous Location LED Strip Light for North America applications, but will not meet the required specifications for ATEX/IECEx. LMBWLS27H
  • 300 series stainless steel mounting brackets
  • M4 stainless steel hardware included 4 xø4.5 ø27.1 LMBWLS27U
  • Clear copolyester
  • Clearance for M5 or #10 hardware
  • Clamps securely around the light body 5 xø5.5 45 25 45ø27.2 All measurements are listed in millimeters, unless noted otherwise. Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. FCC Part 15 and CAN ICES-3 (B)/NMB-3(B) This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the manufacturer. Repairs Contact Banner Engineering for troubleshooting of this device. Do not attempt any repairs to this Banner device; it contains no field-replaceable parts or components. If the device, device part, or device component is determined to be defective by a Banner Applications Engineer, they will advise you of Banner's RMA (Return Merchandise Authorization) procedure. Important: If instructed to return the device, pack it with care. Damage that occurs in return shipping is not covered by warranty. HLS27 Hazardous Location LED Strip Light © Banner Engineering Corp. All rights reserved