HLC-1550A TADIRN | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
THE INFORMATION PROVIDED HERE IS NECESSARILY OF A GENERAL NATURE . SINCE SPECIFIC PERFORMANCE DEPENDS ON ACTUAL OPERATING AND ST ORAGE CONDITIONS, OUR ENGINEERS WILL PROVIDE PARTICULAR APPLICATION INSTRUCTIONS UPON REQUEST. DATA SUBJECT TO REVISION WITHOUT NOTICE. ANY REPRESENT ATION IN THIS BROCHURE CONCERNING PERFORMANCE ARE FOR INFORMATION PURPOSES ONLY AND NOT WARRANTIES, EITHER EXPRESSED OR IMPLIED, OF FUTURE PERFORMANCE. TADIRAN’S STANDARD LIMITED WARRANTY, STATED IN ITS SALES CONTRACT OR ORDER CONFIRMATION FORM IS THE ONLY WARRANTY OFFERED BY TADIRAN. Rev F, April 2011 1 of 3 ECN 6101551 HHHLLLCCC ––– 111555555000AAA Hybrid Layer Capacitor (HLC) For PulsesPlusTM batteries Electrical characteristics (For batteries stored at RT for 1 year or less) Capacity when charge to 3.67 V 560 As Capacity when charge to 3.90 V 850 As Discharge end voltage 2.5 V (discharge below 2.5 V at RT may increase the HLC internal impedance). For other temperatures and discharge condition please contact Tadiran for these end voltage conditions. Mechanical characteristics Length 51 mm. max Diameter 15.1 mm. max Weight 18.8 gr. max Operating conditions Maximum discharge current: Continuous 2.0 A (without PTC) Pulse, 1 sec 5.0 A (without PTC) Charge (constant current) Max. charge voltage 3.95 V Max. charge current 100 mA Operating temperature range HLC in PulsesPlus TM battery -40 °C ÷ +85 °C Storage temperature range of HLC -40 °C ÷ +60 °C Cell impedance at RT < 100 m Ω at 1 kHz Self discharge of PulsesPlusTM battery at RT 3 µA Self discharge PulsesPlusTM battery at 80 0C 15 µA Shelf life at different storage temperature to 80% of initial capacity Temperature HLC HLC in Pulses PlusTM battery RT 3 years 10 years 60 0C 4 weeks 7 years 80 0C 1 week At least 1 year Safety Tested according to: Short circuit at RT and at +55 °C UL, UN, IEC Oven at +150 °C UL, IEC Over-charge & over-discharge (200 % at currents up to 2 A) UL, UN, IEC Impact UL, UN, IEC Compression UL, IEC Shock and vibration UL, IEC UN Manual of Tests and Criteria, UL 1642, IEC 60086 UL Approved under file MH12193 issued December 7th, 2000 Technology Anode: Carbon based Cathode: Multi metal oxides Electrolyte: Organic Shut down separator Key Features Hermetically sealed (glass-to-metal) Wide operating temperature range Low self discharge End of life indication capability High reliability Lightweight Safe design Main Applications Utility Meters (AMR) Asset, Container & Cargo Tracking RFID Devices Sonar Buoys Communication Equipment Emergency & Medical Devices Ordering Part No. HLC-1550A/S 61155122000 HLC-1550A/T 61155122150 HLC-1550A/TP 61155132000 HLC-1550A/PT2 61155135000 Tadiran Batteries Ltd.
34 Yitzhak Rabin Boulevard
Kiryat Ekron 76950, Israel Tel: +972 (8) 944-4555 Fax: +972 (8) 941-3079 www.tadiranbatteries.com WARNING: Fire, Explosion, And Severe Burn Hazard. Do Not Recharge, Crush, Disassemble, Heat Above 100ºC, Incinerate Or Short Circuit.
THE INFORMATION PROVIDED HERE IS NECESSARILY OF A GENERAL NATURE . SINCE SPECIFIC PERFORMANCE DEPENDS ON ACTUAL OPERATING AND ST ORAGE CONDITIONS, OUR ENGINEERS WILL PROVIDE PARTICULAR APPLICATION INSTRUCTIONS UPON REQUEST. DATA SUBJECT TO REVISION WITHOUT NOTICE. ANY REPRESENT ATION IN THIS BROCHURE CONCERNING PERFORMANCE ARE FOR INFORMATION PURPOSES ONLY AND NOT WARRANTIES, EITHER EXPRESSED OR IMPLIED, OF FUTURE PERFORMANCE. TADIRAN’S STANDARD LIMITED WARRANTY, STATED IN ITS SALES CONTRACT OR ORDER CONFIRMATION FORM IS THE ONLY WARRANTY OFFERED BY TADIRAN. Rev F, April 2011 2 of 3 ECN 6101551 HHHLLLCCC ––– 111555555000AAA Voltage curves for HLC1550A at Li/SOCl2 potential (3.67 V), 750 mA Voltage curves for HLC1550A at Li/SOCl2 potential (3.67 V), 1200 mA Voltage curves for HLC1550A at Li/SO2Cl2 potential (3.90 V), 750 mA Available capacity vs. OCV for HLC1550A (at RT, 200 mA discharge) Voltage curves for HLC1550A at Li/SO2Cl2 potential (3.90 V), 1200 mA Performance data Warning:
- The HLC is designed for use in a PulsesPlus TM battery or in low charge current as specified only. The HLC may explode or violently vent if over-charge above 4.4V.
- Do not charge the HLC higher than 4.1 V, over discharge, short circuit, heat above 100 C, incinerate or expose content to water.
- Charging the HLC at above 3.95 V may lead to capacity loss and / or internal impedance rise. 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 1 10 100 1000 10000 TIME [ms] VOLTAGE [V] -40 °C -25 °C 22 °C 85 °C 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 1 10 100 1000 10000 TIME [ms] VOLTAGE [V] -40 °C -25 °C 22 °C 85 °C 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0 1 10 100 1000 10000 TIME [ms] VOLTAGE [V] -40 °C -25 °C 22 °C 85 °C 2.5 2.8 3.0 3.3 3.5 3.8 4.0 0 1 10 100 1000 Capacity [As] OCV [V] 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0 1 10 100 1000 10000 TIME [ms] VOLTAGE [V] -40 °C -25 °C 22 °C 85 °C
THE INFORMATION PROVIDED HERE IS NECESSARILY OF A GENERAL NATURE. SINCE SPECIFIC PERFORMANCE DEPENDS ON ACTUAL OPERATING AND ST ORAGE CONDITIONS, OUR ENGINEERS WILL PROVIDE PARTICULAR APPLICATION INSTRUCTIONS UPON RE QUEST. DATA SUBJECT TO REVISION WITHOUT NOTICE. ANY REPRESENT ATION IN THIS BROCHURE CONCERNING PERFORMANCE ARE FOR INFORMATION PURPOSES ONLY AND NOT WARRANTIES, EITHER EXPRESSED OR IMPLIED, OF FUTURE PERFORMANCE. TADIRAN’S STANDARD LIMITED WARRANTY, STATED IN ITS SALES CONTRACT OR ORDER CONFIRMATION FORM IS THE ONLY WARRANTY OFFERED BY TADIRAN. Rev F, April 2011 3 of 3 ECN 6101551 HHHLLLCCC ––– 111555555000AAA Lead terminations HLC-1550A/T (Soldering Tabs) Cat. # 61155122150 HLC-1550A/TP (PCB Mountable - Polarized) Cat. # 61155132000 HLC-1550A/PT2 (PCB Mountable) Cat. # 61155135000 HLC-1550A/S (Standard) Cat. # 61155122000