HL5030 OMRON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 7

Technical content

General-purpose Limit Switch HL-5000 Economical, Miniature Limit Switch Boasting Rigid Construction

  • The Head, Box, and Cover mate with ridged surfaces to maintain strength.
  • A unique Head structure provides a large OT for smooth operation.
  • Easy-to-wire conduit opening design.
  • Ideal for application in printing machines, forming machines, and light machines. (High Switches with high sealing characteristics, such as WL or D4C Switches, in locations subject to oil, water, or precipitation.)
  • Models with grounding terminals conform to the CE marking.
  • Approved by CCC (Chinese standard). (Ask your OMRON representative for information on approved models.) Be sure to read Safety Precautions on page 4 to 5 and Safety Precautions for All Limit Switches. Model Number Structure Model Number Legend å\`HL-5ņņ (1)(2) (1) Actuators 000: Roller lever 030: Adjustable roller lever 050: Adjustable rod lever 100: Sealed plunger 200: Sealed roller plunger 300: Coil spring (2) Ground Terminal Specifications Blank : Without ground terminal G : With ground terminal/M 5 tapping on the rear side

Ordering Information

  • HL-5000 Limit Switches are offered with a choice of ground terminal/M5 tapping on the rear side conforming to various standards. When placing an order, add the code to the model number to indicate if ground terminal/M5 tapping on the rear side is required. -G: with ground terminal/M5 tapping on the rear side. Specifications Approved Standards Note: Ask your OMRON representativ e for information on approved models. Ratings Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. Lamp load has an inrush current of 10 times the steady-state current. 4. Motor load has an inrush current of 6 times the steady-state current. Approved Standard Ratings CCC (GB14048.5) Actuator Model Roller lever HL-5000 * Adjustable roller lever HL-5030 * Adjustable rod lever HL-5050 * Sealed plunger HL-5100 * Sealed roller plunger HL-5200 Coil spring HL-5300 (Not all combinations are possible. Ask your OMRON representative for details.) HL-5@@ Agency Standard File No. CCC (CQC) GB14048.5 2003010303077624 Rated voltage Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO 125 VAC 51 . 5 0 . 7 32 1 250 VAC 5 1 0.5 3 1.5 0.8

12 VDC 5343

24 VDC 5343

NC 24 A max. NO 12 A max. Applicable category and ratings AC-15 3 A/250 VAC

Note: 1. The above figures are initial values. 2. The above characteristics may vary depending on the model. For further details, contact your OMRON sales representative. * The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments. Engineering Data Electrical Durability (cos dia. =1) (Operating temperature: +5°C to +35°C, Operating humidity: 40% to 70%RH) Structure and Nomenclature Structure Contact Form Degree of protection IP65 Durability * Mechanical 10,000,000 operations min. (under rated conditions) Electrical See the following Electrical Durability. Operating speed 5 mm/s to 0.5 m/s Operating frequency Mechanical 120 operations/min Electrical 30 operations/min Insulation resistance 100 MΩ min. (at 500 VDC) Contact resistance 25 mΩ max. (initial value) Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity 1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground 1,500 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal part Rated frequency 50/60 Hz Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude Shock resistance Destruction 1,000 m/s2 min. Malfunction 300 m/s2 min. Ambient operating temperature −5°C to +65°C (with no icing) Ambient operating humidity 35% to 95%RH Weight Approx. 130 to 190 g 1,000 500 0 12 34 56 Switching current (A) Operating frequency: 30 operations/min 125 VAC (cos dia. = 1) Durability (x 10 operations) Cover Resin roller Lever Head Built-in switch Connector 3 (NO) 2 (NC) (NO) 4 (NC) 1 Za

Dimensions and Operating Characteristics (Unit: mm) Switches (Dimensions not shown are the same as roller lever models.) Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. * Measured with the types of the 31.5-mm arm or rod length. OF and RF measured at the arm length of 75 mm for HL-5030, and 145 mm for HL-5050 (reference values). Operating characteristics Model HL-5000 HL-5030 * HL-5050 * HL-5100 HL-5200 HL-5300 Operating force Release force Pretravel Overtravel Movement Differential OF max. RF min. PT max. OT min. MD max. 7.35 N 0.98 N 20° 50° 12° 7.35 N 0.98 N 20° 50° 12° 7.35 N 0.98 N 20° 50° 12° 8.83 N 1.47 N 1.5 mm 4 mm 1 mm 8.83 N 1.47 N 1.5 mm 4 mm 1 mm 1.47 N 30 mm Operating position OP −−− 30±0.8 mm 40 ±0.8 mm − HL-5030 HL-5050 OF 3.09 N 1.60 N RF 0.41 N 0.22 N 17.5 dia. × 6.6 resin roller *1 4.1 60.6 21.4 58 ±0.8 53±0.8 15.5 Three, M3 Rubber connector 31.5R (19) 16.5 18.5 39.5±0.8 40.3±0.8 M5 × 12 Allen-head bolt (110) 50±0.2 24±0.2 *1. The lever can be mounted anywhere in 360°. *2. The head can be mounted in any of the four directions. Two, 5.2 dia.+0.2 mounting holes Roller Lever HL-5000 Adjustable up to 30R to 75R 4.1 60.6 21.4 65.7±0.8 60.3±0.8 51.3±0.8 15.5 Three, M3 (19) 16.5 39.5±0.8 17.5 dia. × 6.6 *1 M5 × 12 Allen-head bolt × 16 Allen-head bolt ±0.2 *1. Resin roller *2. The head can be mounted in any of the four directions. Adjustable Roller Lever HL-5030 4.1 60.6 21.4 62.8±0.8 53.4±0.8 15.5 145 max. (19) 16.5*2 3 dia. × 160 *1 M5 × 12 Allen-head bolt × 16 Allen-head bolt ±0.2 *1. Stainless steel rod *2. The head can be mounted in any of the four directions. 39.5±0.8 5.4 Three, M3 Adjustable Rod Lever HL-5050 60.6 20.2 (19) 16.5 OP 50±0.2 4.1 PT 8 dia. * * Stainless steel plunger Two, M3 Three, M3 Sealed Plunger HL-5100 60.6 20.2 (19) 16.5 OP 50±0.2 4.1 PT 12.7 dia. × 4.8 *1 *1. Stainless sintered alloy roller *2. The head can be mounted in either of the two directions. Two, M3 Three, M3 Sealed Roller Plunger HL-5200 60.6 20.2 (19) 16.5 110±2.5 50±0.2 4.1 *1. Resin rod *3. The operating range of the dog or cam is the top third (i.e. from the tip of the rod) of the whole actuator. Two, M3 Three, M3 38±0.2 42±0.2 30 *2 PT 3.2 dia. 6.6 dia. *2. The coil spring may be operated from any directions except axial directions ( ). Coil Spring HL-5300

Refer to Safety Precautions for All Limit Switches. Operating Environment

  • Seal material may deteriorate if a Switch is used outdoor or where subject to special cutting oils, solvents, or chemicals. Always appraise performance under actual application conditions and set suitable maintenance and replacement periods.
  • Install Switches where they will not be directly subject to cutting chips, dust, or dirt. The Actuator and Switch must also be protected from the accumulation of cutting chips or sludge.
  • Constantly subjecting a Switch to vibration or shock can result in wear, which can lead to contact interference with contacts, operation failure, reduced durability, and other problems. Excessive vibration or shock can lead to false contact operation or damage. Install Switches in locations not subject to shock and vibration and in orientations that will not produce resonance.
  • The Switches have physical contacts. Using them in environments containing silicon gas will result in the formation of silicon oxide (SiO2) due to arc energy. If silicon oxide accumulates on the contacts, contact interference can occur. If silicon oil, silicon filling agents, silicon cables, or other silicon products are present near the Switch, suppress arcing with contact protective circuits (surge killers) or remove the source of silicon gas. Wiring Wiring Procedure 1. Loosen the cover mounting screws and remove the cover. 2. Disconnect the rubber connector from the box conduit and crimp a solderless terminal. The following solderless terminals are available. 3. After inserting the solderless terminal into the Switch, tighten the terminal screws securely. 4. After wiring the Limit Switch, insert the rubber connector into the groove of the box securely. 5. Tighten the three mounting screws evenly. The optimum tightening torque for each screw is 0.49 to 0.59 N·m. Applicable Lead Wires Note: Do not use wires containing silic one, otherwise a contact failure may result. Applicable Solderless Terminal The following solderless terminals are available. Do not use fork or any other type of terminals, otherwise an accidental disconnection resulting in a ground fault may result. Appropriate Tightening Torque A loose screw may result in a malfunction. Be sure to tighten each screw to the appropriate tightening torque as shown below. Note: If the head direction has been changed, check the torque of each screw and make sure that the screws are free of foreign substances, and that each screw is tightened to the proper torque. Precautions for Correct Use Not Suitable Suitable Cover Cover mounting screw Rubber connector Terminal Wire name Applicable wire Number of conductors Conductor size External size Vinyl cabtire cord (VCTF) 0.75 mm Round, 6 to 9 dia. Flat, 9.4 max. Vinyl cabtire cable (VCT) 2 0.75 mm 600-V vinyl-insulated sheath cable (VVF) 2 1 dia./1.2 dia./ 1.6 dia. Terminal with insulated grip No. Type Appropriate tightening torque 1 Head mounting screw 0.49 to 0.59 N·m 2 Cover mounting screw 0.49 to 0.59 N·m 3 Allen-head bolt 4.90 to 5.88 N·m 4 Terminal screw (M3 screw) 0.49 to 0.59 N·m

5 Switch mounting screw

(M5 Allen-head bolt) 4.90 to 5.88 N·m 6.4 max. 3.0 to 3.7 dia. 14 max. 6.4 max. 14 max. 3.0 to 3.7 dia.

To mount the Limit Switch securely, be sure to use two M5 Allenhead bolts and washers. The tightening torque applied to each bolt is 4.90 to 5.88 N·m. To mount the Limit Switch more securely, use two M5 screw holes on the rear panel and rear holes for positioning if the model is the HL- 5@@@G-Series Limit Switches. Only the HL-5@@@G has M5 x 0.8 (10 depth min) screw holes on the rear side. Others

  • Do not use the Limit Switch outdoors, otherwise the Limit Switch will become damaged by rust or ozone.
  • The Limit Switch is not suitable in places exposed to the spray of rainwater, seawater, or oily water. Consult your OMRON representative for models resisting rainwater, seawater, and oily water.
  • If high-sealing performance is required along with shielded wiring or conduit wiring, use the D4C or WL. Using the Switches Actuator Position Change To change the angle of the actuator, loosen the Allen-head bolt on the side of the actuator lever. Then the actuator can be set at any angle. Head Direction Change (HL-5000, HL-5030, HL-5050, HL5200) To change the head direction, loosen the two mounting screws. Then the head can be changed at 90° increments in one of four directions. The head of the HL-5200 can be mounted in two directions only. (Refer to the following illustration.) 24±0.15 50±0.15 Two, 5.2-dia. holes (located diagonally for securing the rear side) Two, M5 screws or 5.2-dia. holes (located diagonally for securing the front side) Mounting holes Loosen the Allenhead bold Head mounting screw (Small white screw that can be turned with either a Phillips-head or flat-blade screw- driver) Head mounting screw (Black non-removable torque screw) Head mounting screw (Black non-removable torque screw) Head mounting screw (Small white screw that can be turned with either a Phillips head or flat-blade screwdriver) HL-5000 HL-5030 HL-5050 Head mounting screw (white) Head mounting screw (white) HL-5200

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

  • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
  • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.
  • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2009.6 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2009 All Right Reserved.

Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: HL-5000-G HL-5030 HL-5030G HL-5050G HL-5100 HL5100-G HL-5200 HL-5200-G HL-5201 HL-5300 HL- 5300-G HL-5500 HL-5HPH100 HL-5100-G