HL01U CANDD | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
HL01UrevD,10/97 Page 1 GGGGG HIGH EFFICIENCY GGGGG NON-CONDUCTIVE CASE GGGGG SURFACE MOUNT PACKAGE (SMD)
ORDERING INFORMATION
HL Indicates DC/DC Converter Model Number Where: xx = Input Voltage y = Number or Outputs (Single "S", Dual "D") zz = Output Voltage Package Option Screening Option HL01U xxyzz Y/Z /HHL01U xxyzz Y/Z /HHL01U xxyzz Y/Z /HHL01U xxyzz Y/Z /HHL01U xxyzz Y/Z /H ABSOLUTE MAXIMUM RATINGS
DESCRIPTION
The HL01U Series offers an extensive selection of input and output voltages to choose from. These miniature, unregulated DC/DC converters come in 24-pin DIP and SMD packages. This small size is possible through the use of surface mount manufacturing technologies. The HL01U Series utilizes a 125KHz push-pull oscillator in the input stage with internal filtering to reduce the output noise. The use of surface mount construction and automated manufacturing processes increase consistency and reli- ability while reducing overall cost. * Note: Refer to Reflow Profile for SMD Models.
FEATURES
GGGGG SURFACE MOUNT CONSTRUCTION GGGGG TEMPERATURE RANGE: -25°C TO +70°C Product Data Sheet
1 WATT UNREGULATED
Internet: http://www.cdpowerelectronics.com Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Phone: 800.547.2537 Fax: 520.770.9369 Power Electronics Division, Europe C&D T echnologies (Power Electronics) Ltd. 132 Shannon Industrial Estate , Shannon, Co. Clare, Ireland
HL01UrevD,10/97Page 2 NOMINAL RATED RATED INPUT CURRENT INPUT OUTPUT OUTPUT VOLTAGE VOLTAGE CURRENT NO LOAD RATED LOAD EFFICIENCY MODEL (VDC) (VDC) (mA) (mA) (mA) (%) HL01U05S05 5 5 200 30 300 70 HL01U05S12 5 12 83 30 260 74 HL01U05S15 5 15 67 30 260 74 HL01U12S05 12 5 200 25 120 67 HL01U12S12 12 12 83 25 120 70 HL01U12S15 12 15 67 25 120 70 HL01U15S05 15 5 200 20 100 67 HL01U15S12 15 12 83 20 100 70 HL01U15S15 15 15 67 20 100 70 HL01U24S05 24 5 200 15 65 67 HL01U24S12 24 12 83 15 65 70 HL01U24S15 24 15 67 15 65 70 HL01U05D05 5 ±5 ±100 30 300 70 HL01U05D12 5 ±12 ±41 30 260 74 HL01U05D15 5 ±15 ±33 30 260 74 HL01U12D05 12 ±5 ±100 25 120 67 HL01U12D12 12 ±12 ±41 25 120 70 HL01U12D15 12 ±15 ±33 25 120 70 HL01U15D05 15 ±5 ±100 20 100 67 HL01U15D12 15 ±12 ±41 20 100 70 HL01U15D15 15 ±15 ±33 20 100 70 HL01U24D05 24 ±5 ±100 15 65 67 HL01U24D12 24 ±12 ±41 15 65 70 HL01U24D15 24 ±15 ±33 15 65 70 PARAMETER CONDITIONS MIN TYP MAX UNITS INPUT Voltage Range 4.5 5 5.5 VDC 10.8 12 13.2 13.5 15 16.5 22.6 24 26.4 VDC Reflected Ripple Current 30 100 mAp-p ISOLATION Rated Voltage 500 VDC Test Voltage 60 Hz, 10 Seconds 500 Vpk Resistance 1G Ω Capacitance 25 pF Leakage Current V ISO= 240VAC, 60Hz 2 µArms OUTPUT Rated Power 1W Voltage Setpoint Accuracy ±3 ±5 % Temperature Coefficent ±0.02 %/ °C Ripple & Noise BW = DC to 10MHz 50 100 mVp-p BW =10Hz to 2MHz 10 mVrms Line Regulation High Line to Low Line 1 ±1.5 %/% Load Regulation
5 Vout Models 25% Rated Load to Rated Load ±5 ±10 %
All Others 10% Rated Load to Rated Load ±3 ±10 % GENERAL Switching Frequency 125 kHz Package Weight 12 g MTTF per MIL-HDBK-217, Rev. F Circuit Stress Method Ground Benign T A = +25°C 1100 kHr TA = +70°C 550 kHr TEMPERATURE Specification -25 +70 °C Operation -40 +85 °C Storage -40 +110 °C Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified. ELECTRICAL SPECIFICATIONS Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified. COMMON SPECIFICATIONS
HL01UrevD,10/97 Page 3 0.100±0.010" (2.54±0.25) 0.020±0.002" (0.51±0.05) 0.015±0.005" (0.38±0.13) 0.375±0.005" (9.52±0.13) 1.285±0.010" (32.64±0.25) 2423 22 1514 13 121110321 0.014±0.002" (.38±.25) 0.525±0.010" (13.34±0.25) 0.695±0.015" (17.65±0.38) 0°-15° 0.125+0.030" -0.000" (3.18+0.76) ( -0.00) 0.600" (15.24) 0.100±0.010" (2.54±0.25) 0.020±0.002" (0.51±0.05) 0.015±0.005" (0.38±0.13) 0.375±0.005" (9.52±0.13) 1.285±0.010" (32.64±0.25) 2423 22 1514 13 121110321 0.525±0.010" (13.34±0.25) SIDE VIEWS TOP VIEWS END VIEWS SMD PACKAGEDIP PACKAGE HL01UxxyzzY HL01UxxyzzZ NU = Do Not Use. NC = No Internal Connection. Duplicate pin functions are internally connected. All dimensions are in inches (millimeters). GRID: 0.100 inches (2.54 millimeters) Typically Marked with: specific model ordered, date code, job code and Logo. RECOMMENDED LAND PATTERN 2423 22 1514 13 121110321 0.730" (18.54) 1.150" (29.21) 0.100" (2.54) 0.080" (2.03) 0.040" (1.02) 100 150 200 250 TEMPERATURE (°C) TIME (seconds) 235 °C MAX 220 190 30 sec MAX (>220°C) 90 sec MAX (>190°C) RECOMMENDED REFLOW PROFILE PIN CONNECTIONS PIN# SINGLES DUALS 1 +VIN +VIN
2 NU -VOUT
3 NU Common
22 NU Common
23 NU -VOUT
HL01UrevD,10/97Page 4 TYPICAL PERFORMANCE CURVES Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified. VOUT VS LOAD (5Vout Models) VOUT VS LOAD (±5Vout Models) VOUT VS LOAD (12Vout Models) VOUT VS LOAD (±12Vout Models) VOUT VS LOAD (15Vout Models) VOUT VS LOAD (±15Vout Models) EFFICIENCY VS LOAD 0 50 100 150 200 5.3 5.6 5.9 6.2 4.7 5.0 02 0 4 0 6 0 8 0 12.0 12.4 12.8 13.2 13.6 14.0 0 25 50 75 100 4.8 5.1 5.4 5.7 6.0 6.3 01 0 2 0 3 0 4 0 11.8 12.0 12.2 12.4 12.6 12.8 14.6 14.9 15.2 15.5 15.8 16.1 02 0 4 0 6 0 8 0 01 0 20 30 40 14.8 15.0 15.2 15.4 15.6 15.8 0 25 50 75 100 0.0 0.2 0.4 0.6 0.8 1.0 Vout (Volts) Vout (Volts) Vout (Volts) Vout (Volts) Vout (Volts) Vout (Volts)Efficiency (%) Load (mA) Load (mA) Load (mA) Load (mA)Load (mA)Load (mA) Load (mA) SAFE OPERATING AREA SAFE OPERATING AREA Rise Time of Input Voltage (mS) LOAD CAPACITANCE vs INPUT RISE TIME (5 Vout models) Total Load Capacitance (uF) 0 5 10 15 20 25 30 35 40 45 50 600 500 400 300 200 100 SAFE OPERATING AREA Rise Time of Input Voltage (mS) LOAD CAPACITANCE vs INPUT RISE TIME (12 Vout models) Total Load Capacitance (uF) 0 5 10 15 20 25 30 35 40 45 50 SAFE OPERATING AREA Rise Time of Input Voltage (mS) LOAD CAPACITANCE vs INPUT RISE TIME (15 Vout models) Total Load Capacitance (uF) 0 5 10 15 20 25 30 35 40 45 50 NOTES: 1.) When operated within the SAFE OPERATING AREA as defined by the above curves, the output voltage of HL01U devices is guaranteed to be within 95% of its steady-state value within 100 milliseconds after the input voltage has reached 95% of its steady- state value. 2.) For dual output models, total load capacitance is the sum of the capacitances on the plus and minus outputs.