CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 Type HHT 175 °C, Aluminum Electrolytic Capacitor Type HHT has long life and rugged construction for high temperature environments. HHT capacitors are rated for full operating voltage at 175 °C and tested to 2000 hrs at rated voltage and temperature. 5000 hours of life at 150 ºC with ripple current ratings up to 10 Arms. Highlights - Rated for +175 ºC without voltage derating - High capacitance retention @ -40 ºC - Up to 20g vibration Temperature Range –40 °C to +175 °C Rated Voltage Range 16 Vdc to 40 Vdc Capacitance Range 470 µF to 4700 µF Capacitance Tolerance –10 / +30% Leakage Current (at 20 ºC) I = 0.003 CV +4.0 µA; after 5 minutes at rated voltage I = leakage current in µAmps C = rated capacitance in µF V = rated DC Working voltage in Volts Ripple Current vs. Frequency Correction Factors Low Temperature Characteristics Impedance ratio: Z–40 ⁰C ∕ Z+25 ⁰C @120 Hz ≤3 DC Life Test 2000 h @ rated voltage at 175 °C ∆ Capacitance 30V and 40V ±20% , 16V ±25% ESR 200% of limit DCL 100% of limit Shelf Life Test (+105 ºC/0 Vdc): 1000 hours (+40 ºC/0 Vdc): 10 years Case Material Stainless Steel Frequency (Hz) 100 300 1000 5000 100 kHz Ripple Current Correction Factor 0.35 0.57 0.8 1 1.04

CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 Part Numbering System Vibration Test Mil standard 202, method 204, high frequency 20g’s Surge Voltage Test Subject the capacitors to their rated surge voltage at normal room temperature and through a 1000 Ω ±10% resistor (except for capacitances of 2500 µF and up, use a higher value resistor calculated as 2,500,000/C Ω ±10% where C is the capacitance in µF). Cycle the voltage ½ minute on followed by 4½ minutes off during which each capacitor is discharged through the charging resistor or equal resistor. Repeat the cycles for 120 h. Post test requirements are for DCL, ESR and DF to meet initial requirements and for there to be no evidence of mechanical damage or electrolyte leakage. Storage at Low Temperature Test Test Subject the capacitor to 72 hours at -55°C. After 16 hours at room temperature, measure the capacitance and DCL. Capacitance change from the initial measurement must not exceed 10%. DCL Leakage current will meet the initial specification. Appearance No electrolyte leakage or other visible damage. The markings are to be legible. Type HHT 175 °C, Aluminum Electrolytic Capacitor HHT 332 P 016 H J 0 Type Capacitance Tolerance Rated Voltage Case Diameter Case Length Code Sleeve/Label HHT 332 =3300 µF 471 = 470 µF P = -10/+30% 016 = 16 Vdc 030 = 30 Vdc 040 = 40 Vdc H = 22mm E = 37mm J = 45mm L = 53mm 0 = Label 1 = Sleeve

CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 Ratings Cap (µF) 120Hz 25 ˚C Case Size D x L mm ESR max Ripple (A) Voltage Catalog Part Number 25 °C (mΩ) 150 °C Ambient

120 Hz 5 Khz

16 Vdc @ 175 °C

25 Vdc Surge @25 °C

7.1 8.9 10.3

30 Vdc @ 175 °C

40 Vdc Surge @25 °C

7.3 8.9 10.1

40 Vdc @ 175°C

63 Vdc Surge @25°C

5.5 6.9 8.1 Type HHT 175 °C, Aluminum Electrolytic Capacitor Typical Weight HE = 43 g HJ = 50 g HL = 56 g 22.2mm±0.2 "L"±.25mm "L"+5.0mm 28mm MIN Both Sides 2.2mm Both Sides 1.02mm DIA, 18 AWG LEADS (TYP)

Typical Performance Curves CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800 200 400 600 800 1000 1200 1400 1600 1800 2000 1 10 100 1000 10000 100000 1000000 Cap (µF) Freq (Hz) Cap vs. Frequency & Temp -55 -40 -20 0 25 45 65 85 105 125 150 175 0.01 0.1 1.0 1 10 100 1000 10000 100000 1000000 ESR (Ω) Freq (Hz) ESR vs. Frequency & Temp -55 -40 -20 0 25 45 65 85 105 125 150 175 0.01 0.1 1.0 10.0 100.0 1 10 100 1000 10000 100000 1000000 |Z| (Ω) Freq (Hz) |Z| vs. Frequency & Temp -55 -40 -20 0 25 45 65 85 105 125 150 175 Part Number: HHT152PO30HE Type HHT 175 °C, Aluminum Electrolytic Capacitor

Notice and Disclaimer: All product drawings, descriptions, specifications, statements, information and data (collectively, the “Information”) in this datasheet or other publication are subject to change. The customer is responsible for checking, confirming and verifying the extent to which the Information con- tained in this datasheet or other publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without any guaran- tee, warranty, representation or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on the knowledge that the Cornell Dubilier company providing such statements (“Cornell Dubilier”) has of operating conditions that such Cornell Dubilier company regards as typical for such applications, but are not intended to constitute any guarantee, warranty or representa- tion regarding any such matter – and Cornell Dubilier specifically and expressly disclaims any guarantee, warranty or representation concerning the suitability for a specific customer application, use, storage, transportation, or operating environment. The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by Cornell Dubilier with reference to the use of any Cornell Dubilier products is given gratis (unless otherwise specified by Cornell Dubilier), and Cornell Dubilier assumes no obligation or liability for the advice given or results obtained. Although Cornell Dubilier strives to apply the most stringent quality and safety standards regarding the design and manufacturing of its products, in light of the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies or other appropriate protective measures) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product-related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indi- cated in such warnings, cautions and notes, or that other safety measures may not be required.