www.meder.com High Voltage Reed Relays for PCB Mounting HE Series
- High voltage test sets
- Cable testers
- Medical equipment (RF surgery) High voltage Reed Relays for PCB mounting suitable for switching up to 10 kVDC and breakdown voltage up to 15 kVDC. This series is available with high voltage cables. Standard relays available in Form A and Form B switching configurations.
DESCRIPTION
Power switching up to 50 W available Special pin outs available Various case sizes and cable lengths available Air- and creeping distances > 26 mm Part Number Example HE12 - 1A83 - 02 12 is the nominal voltage 1A is the contact form 83 is the switch model 02 is the pinout ORDER INFORMATION Series Nominal Voltage Contact Form Switch Model Pin Out HE XX - XX XX Options 12, 24 1 A 69 02, 03 05, 12, 24 1 A 02. 03, 150 12, 24 1 B 150 12, 24 2 A 69, 83 12 1A 16 24 1A, 2A 16
www.meder.com PIN OUT View from top of component HE Series High Voltage Reed Relays for PCB Mounting DIMENSIONS All dimensions in mm [inch] 15.80 [0.622] 25.40 [1.000] 25.40 [1.000] 65.0±0.5 [2.559±0.02] 15.80 [0.622] 65.0±0.5 [2.559±0.02] 15.80 [0.622] 65.0±0.5 [2.559±0.02] 15.80 [0.622] 65.0±0.5 [2.559±0.02] 57.50 [2.264] 47.50 [1.870] 2.50 [0.098] 15.00 [0.591] 65.0±0.5 [2.559±0.02] 2.50 [0.098] 15.00 [0.591] 47.50 [1.870] 15.80 [0.622] 57.50 [2.264] 65.0±0.5 [2.559±0.02] 15.80 [0.622] 150 [5.905] 150 [5.905] Locking PIN 10.00 [0.394] 15.00 [0.591] 47.50 [1.870] 15.80 [0.622] 65.0±0.5 [2.559±0.02] 150 [5.905] 150 [5.905] Locking PIN 42.50 [1.673] 5.00 [0.197] 5.00 [0.197] 50.80 [2.000] 10.00 [0.394] 57.50 [2.264] 57.50 [2.264] 30.00 [1.181] 5.00 [0.197] 5.00 [0.197] 5.00 [0.197] 5.00 [0.197] ø 0.80 [0.031] ø 0.80 [0.031] ø 0.80 [0.031] ø 0.80 [0.031] ø 0.80 [0.031] ø 0.80 [0.031] ø 0.80 [0.031] 14.5±0.5 [0.571±0.02] TOP VIEW 14.5±0.5 [0.571±0.02] 14.5±0.5 [0.571±0.02] 22.7±0.5 [0.894±0.02] 22.7±0.5 [0.894±0.02] 2.50 [0.098] 14.5±0.5 [0.571±0.02] 1A 150 22.7±0.5 [0.894±0.02] +1B 150 HExx - 1A83 - 02 HExx - 1A69 - 02 HExx - 1A69 HExx - 1A83 HExx - 1A69 - 03 HExx - 1A83 - 03 HExx - 2A HExx - 1B HExx - 1A83 - 150 HExx - 1B83 - 150 HExx - 1B69 - 150 HExx - 1A69 - 150
www.meder.com High Voltage Reed Relays for PCB Mounting RELAY DATA HE Series All Data at 20° C Switch Model → Contact Form → Switch 69 Form A / B Switch 83 Form A / B Switch 16 Form A Switching Power Any DC combination of V & A not to exceed their individual max.‘s 50 50 250 W Switching Voltage DC or peak AC 10 7.5 250 DC/AC kV Switching Current DC or peak AC 3.0 3.0 1.5 A Carry Current DC or peak AC 5.0 5.0 1.5 A Static Contact Resistance w/ 0.5 V & 10mA 150 150 80 mΩ Insulation Resistance 100 volts applied Across Contacts Contacts - Coil 1010 1012 1010 1012 1010 1012 Ω Breakdown Voltage across Contact Voltage applied for 60 sec. min. 15 0.8 6 kVDC Operate Time incl. Bounce Measured w/ nominal voltage 3.0 3.0 4 ms Release Time Measured w/ no coil suppression 1.5 1.5 0.2 ms Capacitance at 10 kHz cross contact 0.8 0.8 5.0 0.8 5.0 pF Life Expectancies Switching 5 V - 10 mA DC only & <10 pF stray cap. 50 50 106 Cycles For other load requirements, see the life test section on P. 120. Environmental Data Shock Resistance 1/2 sinus wave duration 11 ms 30 30 30 g Vibration Resistance From 10 - 2000 Hz 10 10 10 g Ambient Temperature 10°C/ minute max. allowable -20 70 -20 70 -20 70 oC Stock Temperature 10°C/ minute max. allowable -35 105 -35 105 -35 105 oC Soldering Temperature 5 sec. 260 260 260 oC
www.meder.com COIL DATA HE Series Contact Form Switch Model Coil Voltage Coil Resistance Pull-in Voltage Drop-out Volage Nominal Coil Power All Data at 20 °C VDC Ω VDC VDC mW 1A 69 5 7.5 45 50 55 3.8 0.5 500 12 16 225 250 275 9 1 575 24 30 900 1000 1100 18 2 575 1B * 83 5 7.5 90 100 110 3.8 0.5 250 12 16 360 400 440 9 1 360 24 30 1350 1500 1650 18 2 385 2A 16 12 16 432 480 528 9 2 300 24 30 1080 1200 1320 18 3.5 480 The pull-in / drop-out voltage and coil resistance will change at rate of 0.4% per °C. * Re-closure of Form B may occur if the max. coil voltage is exceeded. Coil polarity on Form B must be observed. High Voltage Reed Relays for PCB Mounting