Features

15W Ultra Slim Step Shape DIN Rail HDR-15 seri es HDR-15-5 HDR-15-12 HDR-15-15 HDR-15-24MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INPUT INRUSH CURRENT (Typ.) SAFETY STANDARDS WORKING HUMIDITY WORKING TEMP. STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MTBF DIMENSIONOTHERS NOTE PACKING OVERLOAD Note.4 OVER VOLTAGE 5V 12V 15V 24V 2.4A 1.25A 1A 0.63A 0 ~ 2.4A 0 ~ 1.25A 0 ~ 1A 0 ~ 0.63A 12W 15W 15W 15.2W 80mVp-p 120mVp-p 120mVp-p 150mVp-p 2000ms, 80ms/230VAC 2000ms, 80ms/115VAC at full load 30ms/230VAC 12ms/115VAC at full load 47 ~ 63Hz 80% 85% 85.5% 86% 0.5A/115VAC 0.25A/230VAC COLD START 25A/115VAC 45A/230VAC 110 ~ 145% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed Protection type : Shut off o/p voltage, clamping by zener diode -30 ~ +70℃ (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85℃, 10 ~ 95% RH non-condensing ±0.03%/℃ (0 ~ 50℃) RH non-condensing 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 1166K hrs min. MIL-HDBK-217F (25℃) RIPPLE & NOISE (max.) Note.2 VOLTAGE TOLERANCE Note.3 ENVIRONMENT PROTECTION SAFETY & EMC (Note 5) WITHSTAND VOLTAGE ISOLATION RESISTANCE I/P-O/P:3KVAC I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH 78g;160pcs/13.5Kg/1.19CUFT EMC IMMUNITY EMC EMISSION HDR-15-48 48V 0.32A 0 ~ 0.32A 15.4W 240mVp-p ±1.0% ±1.0% ±1.0% 87% 85 ~ 264VAC (277VAC available ) 120 ~ 370VDC (390VDC available ) File Name:HDR-15-SPEC 2016-11-07 Parameter Conducted Radiated Harmonic Current Voltage Flicker Standard EN61000-3-2 Test Level / Note Class B Class B Class A Parameter ESD Radiated Susceptibility EFT/Burest Surge Standard EN61000-4-2 Test Level /Note Conducted Magnetic Field EN61000-4-3 EN61000-4-4 EN61000-4-6 EN61000-4-5 EN61000-4-8 EN61000-4-11Voltage Dips and interruptions EN55032(CISPR32) Level 3, 8KV air; Level 2, 4KV contact, criteria A Level 4,2KV/L-N, criteria A Level 3, criteria A Level 3, criteria A Level 3, criteria A Level 4, criteria A EN55032(CISPR32) UL60950-1, U 508, TUV EN61558-2-16 IEC60950-1 a EN50178,L , pproved; Design refer to TUV EN60950-1 OPERATING ALTITUDE 2000 meters EN55024, EN55035, EN61000-6-2, EN61204-3 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods

O.L.P. EMI FILTER RECTIFIERS FILTER POWER SWITCHING FILTER RECTIFIERS +V -VI/P CONTROL O.V.P. -30 0 10 20 30 40 50 60 70 (VERTICAL) 100 AMBIENT TEMPERATURE (℃) LOAD (%) Output Derating VS Input Voltage INPUT VOLTAGE (VAC) 60Hz 85 10095 120115 160140 200180 240220 277 LOAD (%) 100 Derating Curve 15W Ultra Slim Step Shape DIN Rail HDR-15 seri es Block Diagram File Name:HDR-15-SPEC 2016-11-07 (available) 264

Terminal Pin No. Assignment Pin No. Pin No. 1 3 Assignment Assignment AC/N AC/L ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 15W Ultra Slim Step Shape DIN Rail HDR-15 seri es 17.5 58.4 54.5 63.65 45.15 (Unit: mm , tolerance ± 0.5mm) File Name:HDR-15-SPEC 2016-11-07 Mechanical Specification Installation Manual Please refer to : http://www.meanwell.com/manual.html