HDC2080 TI1 | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 41
Technical content
RH (%RH) Accuracy (r%RH) 0 10 20 30 40 50 60 70 80 90 100 Typical RH Sensor Temperature Sensor Registers Logic Calibration I2C ADC ADC SCL SDA DRDY/INT ADDR HDC2080 VDD MCU VDD GPIO I2C Master GND GND 1.80V Product Folder Order Now T echnical Documents Tools & Software Support & Community An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications, intellectual property matters and other important disclaimers. PRODUCTION DATA. HDC2080 SNAS678 –MAY 2018 HDC2080LowPowerHumidityandTemperatureDigitalSensor
1 Features
1• Relative Humidity Range: 0% to 100%
- Humidity Accuracy: ±2% (Typical), ±3% (Maximum)
- Temperature Accuracy: ±0.2°C (Typical), ±0.4°C (Maximum)
- Sleep Mode Current: 50 nA (Typical), 100 nA (Maximum )
- Average Supply Current (1 measurement/second) – 300 nA: RH% Only (11 Bit) – 550 nA: RH% (11 Bit) + Temperature (11 Bit)
- Temperature Range: – Operating: –40°C to 85°C – Functional: –40°C to 125°C
- Supply Voltage Range: 1.62 V to 3.6 V
- Available Auto Measurement Mode
- I2C Interface Compatibility
2 Applications
- Smart Thermostats
- Smart Home Assistants
- Washer/Dryers
- HVAC Systems
- Inkjet Printers Typical Application
3 Description
The HDC2080 device is an integrated humidity and temperature sensor that provides high accuracy measurements with very low power consumption in a small DFN package. The capacitive-based sensor includes new integrated digital features and a heating element to dissipate condensation and moisture. The HDC2080 digital features include programmable interrupt thresholds to provide alerts and system wake-ups without requiring a microcontroller to be continuously monitoring the system. Combined with programmable sampling intervals, a low power consumption, and a support for a 1.8-V supply voltage, the HDC2080 is designed for battery- operated systems. The HDC2080 provides high accuracy measurement capability for a wide range of environmental monitoring and Internet of Things (IoT) applications such as smart thermostats and smart home assistants. For designs where printed-circuit board (PCB) area is critical, a smaller CSP package option is available thru the HDC2010 with complete software compatibility with the HDC2080. For applications with strict power-budget restrictions, Auto Measurement Mode enables the HDC2080 to automatically initiate temperature and humidity measurements. This feature allows users to configure a microcontroller into deep sleep mode because the HDC2080 is no longer dependent upon the microcontroller to initiate a measurement. Device Information(1) PART NUMBER PACKAGE BODY SIZE (NOM) HDC2080 WSON (6) 3.00 mm × 3.00 mm (1) For all available packages, see the orderable addendum at the end of the data sheet. RH Accuracy (TA = 30°C)
SNAS678 –MAY 2018 www.ti.com Product Folder Links: HDC2080 Submit Documentation Feedback Copyright © 2018, Texas Instruments Incorporated Table of Contents
12.1 Receiving Notification of Documentation Updates 32
13 Mechanical, Packaging, and Orderable
4 Revision History
May 2018 * Initial release.
www.ti.com SNAS678 –MAY 2018 Product Folder Links: HDC2080 Submit Documentation FeedbackCopyright © 2018, Texas Instruments Incorporated
5 Description (continued)
Programable temperature and humidity thresholds in the HDC2080 allow the device to send a hardware interrupt to wake up the microcontroller when necessary. In addition, the power consumption of the HDC2080 is significantly reduced, which helps to minimize self-heating and improve measurement accuracy. The HDC2080 is factory-calibrated to 0.2°C temperature accuracy and 2% relative humidity accuracy.
6 Pin Configuration and Functions
NAME NO. SDA 1 I/O Serial data line for I2C, open-drain; requires a pullup resistor to VDD GND 2 G Ground ADDR 3 I Address select pin – leave unconnected or hardwired to VDD or GND. Unconnected slave address: 1000000 GND: slave address: 1000000 VDD: slave address: 1000001 DRDY/INT 4 O Data ready/Interrupt VDD 5 P Positive Supply Voltage SCL 6 I Serial clock line for I2C, open-drain; requires a pullup resistor to VDD
SNAS678 –MAY 2018 www.ti.com Product Folder Links: HDC2080 Submit Documentation Feedback Copyright © 2018, Texas Instruments Incorporated (1) Stresses beyond those listed under Absolute Maximum Rating may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Condition. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
7 Specifications
7.1 Absolute Maximum Ratings(1)
VDD Input Voltage -0.3 3.9 V GND Input Voltage -0.3 3.9 V ADDR Input Voltage -0.3 3.9 V SCL Input Voltage -0.3 3.9 V SDA Input Voltage -0.3 3.9 V Tstg Storage temperature -65 150 °C (1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process. (2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.
7.2 ESD Ratings
V(ESD) Electrostatic discharge Human body model (HBM), per ANSI/ESDA/JEDEC JS-001, all pins(1) ±2000 V Charged device model (CDM), per JEDEC specification JESD22-C101, all pins(2) ±500
7.3 Recommended Operating Conditions
over operating range (unless otherwise noted) MIN NOM MAX UNIT VDD Voltage Supply 1.62 3.6 V TTEMP Temperature Sensor - Operating free-air temperature -40 125 °C TRH Relative Humidity Sensor - Operating free-air temperature -20 70 °C THEATER Integrated Heater - Operating free-air temperature -40 85 °C (1) For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application report.
7.4 Thermal Information
THERMAL METRIC(1) HDC2080 UNITPWSON (DMB)
6 PINS
RθJA Junction-to-ambient thermal resistance 56.4 °C/W RθJC(top) Junction-to-case (top) thermal resistance 73.6 °C/W RθJB Junction-to-board thermal resistance 24.0 °C/W ΨJT Junction-to-top characterization parameter 3.8 °C/W ΨJB Junction-to-board characterization parameter 24.0 °C/W RθJC(bot) Junction-to-case (bottom) thermal resistance 13.0 °C/W (1) I2C read/write communication and pull up resistors current through SCL, SDA not included.
7.5 Electrical Characteristics
at TA = 30°C, VDD = 1.8 V, 20% ≤ RH ≤ 80% (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT ELECTRICAL SPECIFICATION VDD Supply Voltage Operating Range 1.62 3.6 V IDD Supply current RH measurement(1) 650 890 µA
www.ti.com SNAS678 –MAY 2018 Product Folder Links: HDC2080 Submit Documentation FeedbackCopyright © 2018, Texas Instruments Incorporated Electrical Characteristics (continued) at TA = 30°C, VDD = 1.8 V, 20% ≤ RH ≤ 80% (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT (2) Average current consumption while conversion is in progress. (3) Heater operating range: – 40°C to 85°C. (4) Excludes hysteresis and long-term drift. (5) Excludes the impact of dust, gas phase solvents and other contaminants such as vapors from packaging materials, adhesives, or tapes, etc. (6) Limits apply over the humidity operating range 20 to 80% RH (non-condensing) from 0 to 60°C. (7) This parameter is specified by design and/or characterization and is not tested in production. (8) The hysteresis value is the difference between an RH measurement in a rising and falling RH environment, at a specific RH point. (9) Actual response times will vary dependent on system thermal mass and air-flow. (10) Time for the RH output to change by 63% of the total RH change after a step change in environmental humidity. (11) Recommended humidity operating range is 20 to 80% RH (non-condensing) over 0 to 60°C. Prolonged operation beyond these ranges may result in a shift of sensor reading, with slow recovery time. (12) Drift due to aging effects at typical conditions (30°C and 20% to 50% RH). This value may be impacted by dust, vaporized solvents, outgassing tapes, adhesives, packaging materials, etc. IDD Supply current Temperature measurement(1) 550 730 µA IDD Supply current Sleep Mode 0.05 0.1 µA IDD Supply current Average at 1 measurement/second, RH or temperature only(1) (2) 0.3 µA IDD Supply current Average at 1 measurement/second, RH (11 bit)+temperature (11 bit)(1) (2) 0.55 µA IDD Supply current Average at 1 measurement every 2 seconds, RH (11 bit) + temperature (11 bit)(1) (2) 0.3 µA IDD Supply current Average @ 1 measurement every 10 seconds, RH (11 bit)+temperature (11 bit) 0.105 µA IDD Supply current Startup (average on startup time) 80 µA IDDHEAT Integrated Heater (when enabled)(3) VDD = 3.3 V and TA = -40°C to 85°C 90 mA RELATIVE HUMIDITY SENSOR RHACC Accuracy(4) (5) (6) ±2 ±3 %RH RHREP Repeatability(7) 14 bit resolution ±0.1 %RH RHHYS Hysteresis(8) ±1 %RH RHRT Response Time(9) t63% step(10) 8 sec RHCT Conversion-time(7) 9 bit accuracy 275 µs RHCT Conversion-time(7) 11 bit accuracy 400 µs RHCT Conversion-time(7) 14 bit accurcay 660 µs RHOR Operating range Non-condensing(11) 0 100 %RH RHLTD Long-term Drift(12) ±0.25 %RH/yr TEMPERATURE SENSOR TEMPOR Operating range -40 125 °C TEMPAC C Accuracy(7) 5°C < TA < 60°C ±0.2 ±0.4 °C TEMPRE P Repeatability(7) 14 bit resolution ±0.1 °C TEMPCT Conversion-time(7) 9 bit accuracy 225 µs TEMPCT Conversion-time(7) 11 bit accuracy 350 µs TEMPCT Conversion-time(7) 14 bit accurcay 610 µs
7.6 I2C Interface Electrical Characteristics
At TA = 30°C, VDD = 3.3 V (unless otherwise noted). PARAMETER TEST CONDITIONS MIN TYP MAX UNIT VIH Input High Voltage 0.7 x VDD V VIL Input Low Voltage 0.3 x VDD V
At TA = 30°C, VDD = 3.3 V (unless otherwise noted). (1) This parameter is specified by design and/or characterization and it is not tested in production. (1) This parameter is specified by design and/or characterization and it is not tested in production.
7.7 I2C Interface Timing Requirements
7.8 Timing Diagram
Figure 1. I2C Timing
7.9 Typical Characteristics
Unless otherwise noted. TA = 30°C, VDD = 1.80 V. Figure 2. RH Accuracy vs. RH Set Point Figure 3. Temperature Accuracy vs. Temperature Set Point
SNAS678 –MAY 2018 www.ti.com Product Folder Links: HDC2080 Submit Documentation Feedback Copyright © 2018, Texas Instruments Incorporated
8 Detailed Description
8.1 Overview
The HDC2080 is a highly integrated digital humidity and temperature sensor that incorporates both humidity- sensing and temperature-sensing elements, an analog-to-digital converter, calibration memory, and an I2C interface that are all contained in a 3.00-mm × 3.00-mm 6-pin WSON package. The HDC2080 provides excellent measurement accuracy with very low power consumption and features programmable resolution for both humidity and temperature:
- Temperature resolution [9, 11, 14]
- Humidity resolution [9, 11, 14] The conversion time during measurements is dependent upon the configured resolution for humidity and temperature, which can be configured for optimal power consumption. The HDC2080 device incorporates a state-of-the-art polymer dielectric to provide capacitive-sensing measurements. As with most relative humidity sensors that include this type of technology, the user must meet certain application requirements to ensure optimal device performance for the sensing element. The user must:
- Follow the correct storage and handling procedures during board assembly. See Humidity Sensor: Storage and Handling Guidelines. (SNIA025) for these guidelines.
- Protect the sensor from contaminants during board assembly and operation.
- Reduce prolonged exposure to both high temperature and humidity extremes that may impact sensor accuracy.
- Follow the correct layout guidelines for best performance. See Optimizing Placement and Routing for Humidity Sensors (SNAA297) for these guidelines.
8.2 Functional Block Diagram
8.3 Feature Description
8.3.1 Sleep Mode Power Consumption
One key feature of the HDC2080 is the low power consumption of the device, which makes the HDC2080 suitable in battery-powered or energy-harvesting applications. In these applications, the HDC2080 spends most of the time in sleep mode that has a typical current consumption of 50 nA. This minimizes the average power consumption and self-heating. 8.3.2 Measurement Modes: Trigger on Demand vs. Auto Measurement Two types of measurement modes are available on the HDC2080: Trigger on Demand and Auto Mode. Trigger on Demand is when each measurement reading are initiated through an I2C command on an as-needed basis. After the measurement is converted, the device remains in sleep mode until another I2C command is received.
www.ti.com SNAS678 –MAY 2018 Product Folder Links: HDC2080 Submit Documentation FeedbackCopyright © 2018, Texas Instruments Incorporated Feature Description (continued) Auto Measurement Mode is when the HDC2080 is programmed to perform measurement readings on a periodic basis, thus eliminating the need to initiate a measurement request through an I2C command and improves power consumption. The user can adjust the Soft Reset and Interrupt Configuration register to select one of 7 different sampling rates (the range spans from 1 sample every 2 minutes to 5 samples/second). In Auto Measurement Mode, the HDC2080 wakes up from sleep to measurement mode based on the selected sampling rate.
8.3.3 Heater
The HDC2080 includes an integrated heating element that can be switched on briefly to prevent or remove any condensation that may build up in high humidity environments. Additionally, the heater can be used to verify functionally of the integrated temperature sensor. The operating range of the heater should be limited to –40°C to 85°C. For 3.3-V operation, the heater will have a typical current draw of 90 mA, and 55 mA at 1.8-V operation.
8.3.4 Interrupt Description
When multiple bits are enabled, the DRDY/INT pin can only reflect the status of one interrupt bit at a time. The DRDY/INT pin DOES NOT function as the logical ‘OR’ of interrupt bits that have been enabled. The highest priority is given to TH_ENABLE bit, followed by TL_ENABLE, HH_ENABLE, and HL_ENABLE bits in descending order. Therefore, programming recommendations are provided as below:
- The DRDY/INT will track the HL_ENABLE if enabled and all other ENABLE bits are disabled
- The DRDY/INT will track the HH_ENABLE if enabled and the TH_ENABLE and TL_ENABLE are disabled
- The DRDY/INT will track the TL_ENABLE if enabled and the TH_ENABLE is disabled
- The DRDY/INT will track the TH_ENABLE if enabled and is independent of other ENABLE bit settings
8.3.4.1 DRDY
Figure 8. Data Ready Interrupt - Active High (INT_POL = 1) Figure 9. Data Ready Interrupt - Active Low (INT_POL = 0)
8.3.5 INTERRUPT on Threshold
8.3.5.1 Temperature High
The INT_MODE bit sets the threshold to either comparator mode or a level sensitive alarm. Figure 10. INTERRUPT on Threshold - Temperature High
8.3.5.2 Temperature Low
based on the INT_POL and INT_MODE bits. The INT_MODE bit sets the threshold to either comparator mode or a level sensitive alarm. Figure 11. INTERRUPT on Threshold - Temperature Low
8.3.5.3 Humidity High
The INT_MODE bit sets the threshold to either comparator mode or a level sensitive alarm. Figure 12. INTERRUPT on Threshold - Humidity High
8.3.5.4 Humidity Low
The INT_MODE bit sets the threshold to either comparator mode or a level sensitive alarm. Figure 13. INTERRUPT on Threshold - Humidity Low
8.4 Device Functional Modes
The HDC2080 has two modes of operation: Sleep Mode and Measurement Mode. Configuration registers. After completing the conversion, the HDC2080 returns to Sleep Mode.
8.5 Programming
8.5.1 I2C Serial Bus Address Configuration
To communicate with the HDC2080, the master must first address slave devices through a slave address byte. any activity on the interface occurs and remain constant while the device is powered up. Table 1. HDC2080 I2C Slave Address
8.5.2 I2C Interface
measurement is performed. All data bytes are transmitted MSB first.
8.5.3 Serial Bus Address
To communicate with the HDC2080, the master must first address slave devices through a slave address byte.
8.5.4 Read and Write Operations
operation to the HDC2080 requires a value for the register address (refer to Table 2).
read or write operation with incorrect I2C address returns a NACK after the I2C address. Table 2. Write Single Byte Table 3. Write Multi Byte Table 4. Read Single Byte Table 5. Read Multi Byte
8.6 Register Maps
measurement results, and status information. Table 6. Register Map
8.6.1 Address 0x00 Temperature LSB
Table 7. Address 0x00 Temperature LSB Register Table 8. Address 0x00 Temperature LSB Field Descriptions
8.6.2 Address 0x01 Temperature MSB
Configuration register. The temperature must be read LSB first. Table 9. Address 0x01 Temperature MSB Register Table 10. Address 0x01 Temperature MSB Field Descriptions
8.6.3 Address 0x02 Humidity LSB
Table 11. Address 0x02 Humidity LSB Register Table 12. Address 0x02 Humidity LSB Field Descriptions
8.6.4 Address 0x03 Humidity MSB
Configuration register. The humidity measurement must be read LSB first. Table 13. Address 0x03 Humidity MSB Register Table 14. Address 0x03 Temperature MSB Field Descriptions
8.6.5 Address 0x04 Interrupt DRDY
Table 15. Address 0x04 Interrupt DRDY Register Table 16. Address 0x04 Interrupt DRDY Field Descriptions
7 DRDY_STATUS R/W 0 DataReady bit status
6 TH_STATUS R/W 0 Temperature threshold HIGH Interrupt status
5 TL_STATUS R/W 0 Temperature threshold LOW Interrupt status
4 HH_STATUS R/W 0 Humidity threshold HIGH Interrupt status
3 HL_STATUS R/W 0 Humidity threshold LOW Interrupt status
2 RES 0 Reserved
1 RES 0 Reserved
0 RES 0 Reserved
HUMIDITY_HIGH and HUMIDITY_LOW are read. 0x0E Configuration register value. The bit is cleared when the register Interrupt DRDY is read. 0x0E Configuration register value. The bit is cleared when the register Interrupt DRDY is read. 0x0E Configuration register value. The bit is cleared when the register Interrupt DRDY is read. 0x0E Configuration register value. The bit is cleared when the register Interrupt DRDY is read. DRDY/INT pin behaves like the STATUS bits based on the 0x0E Configuration register value.
8.6.6 Address 0x05 Temperature MAX
after the power up. Value is reset at power up and/or with soft reset procedure. Table 17. Address 0x05 Temperature MAX Register Table 18. Address 0x05 Temperature Max Field Descriptions
8.6.7 Address 0x06 Humidity MAX
power up. Value is reset at power up and/or with soft reset procedure. Table 19. Address 0x06 Humidity MAX Register Table 20. Address 0x06 Humidity MAX Field Descriptions
8.6.8 Address 0x07 Interrupt Configuration
Table 21. Address 0x07 Interrupt Configuration Register Table 22. Address 0x07 Interrupt Configuration Field Descriptions
7 DRDY_ENABLE R/W 0 DataReady Interrupt enable
6 TH_ENABLE R/W 0 Temperature threshold HIGH Interrupt enable
5 TL_ENABLE R/W 0 Temperature threshold LOW Interrupt enable
4 HH_ENABLE R/W 0 Humidity threshold HIGH Interrupt enable
3 HL_ENABLE R/W 0 Humidity threshold LOW Interrupt enable
8.6.9 Address 0x08 Temperature Offset Adjustment
Table 23. Address 0x08 Temperature Offset Adjustment Register Table 24. Address 0x08 Temperature Offset Adjustment Field Descriptions Figure 14. Temperature Output Calculation
- Programming TEMP_OFFSET_ADJUST to 00000001 adjusts the reported temperature by +0.16°C
- Programming TEMP_OFFSET_ADJUST to 00000111 adjusts the reported temperature by +1.12°C
- Programming TEMP_OFFSET_ADJUST to 00001101 adjusts the reported temperature by +2.08°C
- Programming TEMP_OFFSET_ADJUST to 11111111 adjusts the reported temperature by -0.16°C
- Programming TEMP_OFFSET_ADJUST to 11111001 adjusts the reported temperature by -1.12°C
- Programming TEMP_OFFSET_ADJUST to 11110011 adjusts the reported temperature by -2.08°C
8.6.10 Address 0x09 Humidity Offset Adjustment
Table 25. Address 0x09 Humidity Offset Adjustment Register Table 26. Address 0x09 Humidity Offset Adjustment Field Descriptions Figure 15. Humidity Output Calculation The resulting humidity offset is a summation of the register bits that have been enabled (i.e. programmed to 1).
- Programming HUM_OFFSET_ADJUST to 00000001 adjusts the reported humidity by +0.20%RH
- Programming HUM_OFFSET_ADJUST to 00000101 adjusts the reported humidity by +1.00%RH
- Programming HUM_OFFSET_ADJUST to 00001010 adjusts the reported humidity by +2.00%RH
- Programming HUM_OFFSET_ADJUST to 11111111 adjusts the reported humidity by -0.10%RH
- Programming HUM_OFFSET_ADJUST to 11111011 adjusts the reported humidity by -0.90%RH
- Programming HUM_OFFSET_ADJUST to 11110101 adjusts the reported humidity by -2.10%RH
8.6.11 Address 0x0A Temperature Threshold LOW
Table 27. Address 0x0A Temperature Threshold LOW Register Table 28. Address 0x0A Temperature Threshold LOW Field Descriptions
8.6.12 Address 0x0B Temperature Threshold HIGH
Table 29. Address 0x0B Temperature Threshold HIGH Register Table 30. Address 0x0B Temperature Threshold HIGH Field Descriptions
8.6.13 Address 0x0C Humidity Threshold LOW
Table 31. Address 0x0C Humidity Threshold LOW Register Table 32. Address 0x0C Humidity Threshold LOW Field Descriptions
8.6.14 Address 0x0D Humidity Threshold HIGH
Table 33. Address 0x0D Humidity Threshold HIGH Register Table 34. Address 0x0D Humidity Threshold HIGH Field Descriptions
8.6.15 Address 0x0E Reset and DRDY/INT Configuration Register
Table 35. Address 0x0E Configuration Register Table 36. Address 0x0E Configuration Field Descriptions
7 SOFT_RES R/W 0 0 = Normal Operation mode, this bit is self-clear
3 HEAT_EN R/W 0 0 = Heater off
2 DRDY/INT_EN R/W 0 DRDY/INT_EN pin configuration
1 INT_POL R/W 0 Interrupt polarity
0 INT_MODE R/W 0 Interrupt mode
8.6.16 Address 0x0F Measurement Configuration
Table 37. Address 0x0F Measurement Configuration Register Table 38. Address 0x0F Measurement Configuration Field Descriptions
3 RES R/W 0 Reserved
0 MEAS_TRIG R/W 0 Measurement trigger
8.6.17 Manufacturer ID Low
Table 39. Manufacturer ID Low Register Table 40. Address 0xFC Manufacturer ID Low Field Descriptions
8.6.18 Manufacturer ID High
Table 41. Manufacturer ID High Register Table 42. Address 0xFD Manufacturer ID High Field Descriptions
8.6.19 Device ID Low
Table 43. Device ID Low Register Table 44. Address 0xFE Device ID Low Field Descriptions
8.6.20 Device ID High
These registers contain a factory-programmable identification value that identifies this device as a HDC2080. Table 45. Device ID High Register Table 46. Address 0xFF Device ID High Field Descriptions
9 Application and Implementation
validate and test their design implementation to confirm system functionality.
9.1 Application Information
system. The collected data are then shown on a display that can be easily controlled by the microcontroller. environment at the customer-defined preferred conditions.
9.2 Typical Application
Figure 16. Typical Application Schematic HVAC
9.2.1 Design Requirements
9.2.2 Detailed Design Procedure
When a circuit board layout is created from the schematic shown in Figure 16, a small circuit board is possible. which can improve measurement response time and accuracy.
9.2.3 Application Curve
Figure 17. RH% Readings of Chamber and HDC2080 vs. Time
SNAS678 –MAY 2018 www.ti.com Product Folder Links: HDC2080 Submit Documentation Feedback Copyright © 2018, Texas Instruments Incorporated
10 Power Supply Recommendations
The HDC2080 requires a voltage supply within 1.62 V and 3.60 V. TI recommends a multilayer ceramic bypass X7R capacitor of 0.1 µF between the VDD and GND pins.
11 Layout
11.1 Layout Guidelines
The HDC2080’s relative humidity-sensing element is located on the top side of the package. TI recommends that the user eliminate the copper layers below the device (GND, VDD) and create slots in the PCB around the device to enhance the thermal isolation of the HDC2080. To ensure the temperature sensor performance, TI highligh recommends that the user follow the Land Pattern, Solder Mask, and Solder Paste examples depicted in the Mechanical, Packaging, and Orderable Information.
11.1.1 Guidelines for HDC2080 Storage and PCB Assembly
11.1.1.1 Storage and Handling
As with all humidity sensors, the HDC2080 must follow special guidelines regarding handling and storage that are not common with standard semiconductor devices. Long exposure to UV and visible light, or exposure to chemical vapors for prolonged periods, should be avoided as it may affect RH% accuracy. Additionally, the device should be protected from out-gassed solvent vapors produced during manufacturing, transport, operation, and package materials (that is, adhesive tapes, stickers, bubble foils). For further detailed information, see Humidity Sensor: Storage and Handling Guidelines (SNIA025)
11.1.1.2 Soldering Reflow
For PCB assembly, standard reflow soldering ovens may be used. The HDC2080 uses the standard soldering profile IPC/JEDEC J-STD-020 with peak temperatures at 260°C. When soldering the HDC2080, it is mandatory to use no-clean solder paste, and the paste must not be exposed to water or solvent rinses during assembly because these contaminants may affect sensor accuracy. After reflow, it is expected that the sensor will generally output a shift in relative humidity, which will reduce over time as the sensor is exposed to typical indoor ambient conditions. These conditions include 30-40% RH at room temperature during a duration of several days. Following this re-hydration procedure allows the polymer to correctly settle after reflow and return to the calibrated RH accuracy.
11.1.1.3 Rework
TI recommends to limit the HDC2080 to a single IR reflow with no rework, but a second reflow may be possible if the following guidelines are met:
- The exposed polymer (humidity sensor) is kept clean and undamaged.
- The no-clean solder paste is used and the process is not exposed to any liquids, such as water or solvents.
- The Peak soldering temperature does not exceed 260°C.
11.1.1.4 High Temperature and Humidity Exposure
Long exposure outside the recommended operating conditions may temporarily offset the RH output. The recommended humidity operating range is 20 to 80% RH (non-condensing) over 0 to 60°C. Prolonged operation beyond these ranges may shift the sensor reading with a slow recovery time.
11.1.1.5 Bake/Re-Hydration Procedure
Prolonged exposure to extreme conditions or harsh contaminants may impact sensor performance. In the case that permanent offset is observed from contaminants, the following procedure is suggested, which may recover or reduce the error observed in sensor performance: 1. Baking: 100°C, at less than 5%RH, for 5 to 10 hours 2. Re-hydration: Between 20°C to 30°C, 60%RH to 75%RH, for 6 to 12 hours
11.2 Layout Example
Figure 18. HDC2080 PCB Layout Example
SNAS678 –MAY 2018 www.ti.com Product Folder Links: HDC2080 Submit Documentation Feedback Copyright © 2018, Texas Instruments Incorporated
12 Device and Documentation Support
12.1 Receiving Notification of Documentation Updates
To receive notification of documentation updates, navigate to the device product folder on ti.com. In the upper right corner, click on Alert me to register and receive a weekly digest of any product information that has changed. For change details, review the revision history included in any revised document.
12.2 Community Resources
The following links connect to TI community resources. Linked contents are provided "AS IS" by the respective contributors. They do not constitute TI specifications and do not necessarily reflect TI's views; see TI's Terms of Use. TI E2E™ Online Community TI's Engineer-to-Engineer (E2E) Community. Created to foster collaboration among engineers. At e2e.ti.com, you can ask questions, share knowledge, explore ideas and help solve problems with fellow engineers. Design Support TI's Design Support Quickly find helpful E2E forums along with design support tools and contact information for technical support.
12.3 Trademarks
E2E is a trademark of Texas Instruments. All other trademarks are the property of their respective owners.
12.4 Electrostatic Discharge Caution
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
12.5 Glossary
SLYZ022 — TI Glossary. This glossary lists and explains terms, acronyms, and definitions.
13 Mechanical, Packaging, and Orderable Information
The following pages include mechanical, packaging, and orderable information. This information is the most current data available for the designated devices. This data is subject to change without notice and revision of this document. For browser-based versions of this data sheet, refer to the left-hand navigation.
www.ti.com 30-May-2018 Addendum-Page 1 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Drawing Pins Package Qty Eco Plan (2) Lead/Ball Finish (6) MSL Peak Temp (3) Op Temp (°C) Device Marking (4/5) Samples HDC2080DMBR ACTIVE WSON DMB 6 3000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM -40 to 85 3C HDC2080DMBT ACTIVE WSON DMB 6 250 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM -40 to 85 3C (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may reference these types of products as "Pb-Free". RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption. Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of <=1000ppm threshold. Antimony trioxide based flame retardants must also meet the <=1000ppm threshold requirement. (3) MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. (4) There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device. (5) Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation of the previous line and the two combined represent the entire Device Marking for that device. (6) Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish value exceeds the maximum column width. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
www.ti.com 30-May-2018 Addendum-Page 2
*All dimensions are nominal Device Package Type Package Drawing Pins SPQ Reel Diameter (mm) Reel Width W1 (mm) (mm) (mm) (mm) (mm) W (mm) Pin1 Quadrant PACKAGE MATERIALS INFORMATION www.ti.com 27-May-2018 Pack Materials-Page 1
*All dimensions are nominal Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm) HDC2080DMBR WSON DMB 6 3000 335.0 335.0 32.0 HDC2080DMBT WSON DMB 6 250 336.6 336.6 41.3 PACKAGE MATERIALS INFORMATION www.ti.com 27-May-2018 Pack Materials-Page 2
www.ti.com PACKAGE OUTLINE C 6X 0.45 0.35 2.4 0.1 6X 0.5 0.3 1.5 0.1 4X 1
0.8 MAX
0.05 0.00 (1.2) (1.3) B 3.1 2.9 A 3.1 2.9 (0.2) TYP (0.45) (0.22) WSON - 0.8 mm max heightDMB0006A PLASTIC SMALL OUTLINE - NO LEAD 4221225/B 08/2016 PIN 1 INDEX AREA PICK AREA NOTE 4 SEATING PLANE0.08 C 3 4 (OPTIONAL) PIN 1 ID 0.1 C A B 0.05 C THERMAL PAD EXPOSED NOTES: 1. All linear dimensions are in millimeters. Any dimensions in parenthesis are for reference only. Dimensioning and tolerancing per ASME Y14.5M. 2. This drawing is subject to change without notice. 3. The package thermal pad must be soldered to the printed circuit board for thermal and mechanical performance. 4. Pick and place nozzle 0.9 mm or smaller recommended. SCALE 4.000
www.ti.com EXAMPLE BOARD LAYOUT
0.07 MIN
0.07 MAX
(1.5) 4X (1) (2.8) 6X (0.4) 6X (0.6) (2.4) (R0.05) TYP ( 0.2) TYP (0.95) TYP (1) TYP WSON - 0.8 mm max heightDMB0006A PLASTIC SMALL OUTLINE - NO LEAD 4221225/B 08/2016 SYMM SYMM LAND PATTERN EXAMPLE SCALE:20X NOTES: (continued) 5. This package is designed to be soldered to a thermal pad on the board. For more information, see Texas Instruments literature number SLUA271 (www.ti.com/lit/slua271). 6. Vias are optional depending on application, refer to device data sheet. If any vias are implemented, refer to their locations shown on this view. It is recommended that vias under paste be filled, plugged or tented. SOLDER MASK OPENING SOLDER MASK METAL UNDER SOLDER MASK DEFINED METALSOLDER MASK OPENING SOLDER MASK DETAILS NON SOLDER MASK DEFINED (PREFERRED)
www.ti.com EXAMPLE STENCIL DESIGN 6X (0.4) 6X (0.6) 4X (1) 2X (1.06) 2X (1.38) (0.63) (2.8) (R0.05) TYP WSON - 0.8 mm max heightDMB0006A PLASTIC SMALL OUTLINE - NO LEAD 4221225/B 08/2016 NOTES: (continued) 7. Laser cutting apertures with trapezoidal walls and rounded corners may offer better paste release. IPC-7525 may have alternate design recommendations. SOLDER PASTE EXAMPLE BASED ON 0.125 mm THICK STENCIL EXPOSED PAD 7: 81% PRINTED SOLDER COVERAGE BY AREA UNDER PACKAGE SCALE:20X SYMM SYMM METAL TYP
Texas Instruments Incorporated (TI) reserves the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. TI’s published terms of sale for semiconductor products (http://www.ti.com/sc/docs/stdterms.htm) apply to the sale of packaged integrated circuit products that TI has qualified and released to market. Additional terms may apply to the use or sale of other types of TI products and services. Reproduction of significant portions of TI information in TI data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such reproduced documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Buyers and others who are developing systems that incorporate TI products (collectively, “Designers”) understand and agree that Designers remain responsible for using their independent analysis, evaluation and judgment in designing their applications and that Designers have full and exclusive responsibility to assure the safety of Designers' applications and compliance of their applications (and of all TI products used in or for Designers’applications) with all applicable regulations, laws and other applicable requirements. Designer represents that, with respect to their applications, Designer has all the necessary expertise to create and implement safeguards that (1) anticipate dangerous consequences of failures, (2) monitor failures and their consequences, and (3) lessen the likelihood of failures that might cause harm and take appropriate actions. Designer agrees that prior to using or distributing any applications that include TI products, Designer will thoroughly test such applications and the functionality of such TI products as used in such applications. TI’s provision of technical, application or other design advice, quality characterization, reliability data or other services or information, including, but not limited to, reference designs and materials relating to evaluation modules, (collectively, “TI Resources”) are intended to assist designers who are developing applications that incorporate TI products; by downloading, accessing or using TI Resources in any way, Designer (individually or, if Designer is acting on behalf of a company, Designer’s company) agrees to use any particular TI Resource solely for this purpose and subject to the terms of this Notice. TI’s provision of TI Resources does not expand or otherwise alter TI’s applicable published warranties or warranty disclaimers for TI products, and no additional obligations or liabilities arise from TI providing such TI Resources. TI reserves the right to make corrections, enhancements, improvements and other changes to its TI Resources. TI has not conducted any testing other than that specifically described in the published documentation for a particular TI Resource. Designer is authorized to use, copy and modify any individual TI Resource only in connection with the development of applications that include the TI product(s) identified in such TI Resource. NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER TI INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT OF TI OR ANY THIRD PARTY IS GRANTED HEREIN, including but not limited to any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information regarding or referencing third-party products or services does not constitute a license to use such products or services, or a warranty or endorsement thereof. Use of TI Resources may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. TI RESOURCES ARE PROVIDED “AS IS”AND WITH ALL FAULTS. TI DISCLAIMS ALL OTHER WARRANTIES OR REPRESENTATIONS, EXPRESS OR IMPLIED, REGARDING RESOURCES OR USE THEREOF, INCLUDING BUT NOT LIMITED TO ACCURACY OR COMPLETENESS, TITLE, ANY EPIDEMIC FAILURE WARRANTY AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS. TI SHALL NOT BE LIABLE FOR AND SHALL NOT DEFEND OR INDEMNIFY DESIGNER AGAINST ANY CLAIM, INCLUDING BUT NOT LIMITED TO ANY INFRINGEMENT CLAIM THAT RELATES TO OR IS BASED ON ANY COMBINATION OF PRODUCTS EVEN IF DESCRIBED IN TI RESOURCES OR OTHERWISE. IN NO EVENT SHALL TI BE LIABLE FOR ANY ACTUAL, DIRECT, SPECIAL, COLLATERAL, INDIRECT, PUNITIVE, INCIDENTAL, CONSEQUENTIAL OR EXEMPLARY DAMAGES IN CONNECTION WITH OR ARISING OUT OF TI RESOURCES OR USE THEREOF, AND REGARDLESS OF WHETHER TI HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Unless TI has explicitly designated an individual product as meeting the requirements of a particular industry standard (e.g., ISO/TS 16949 and ISO 26262), TI is not responsible for any failure to meet such industry standard requirements. Where TI specifically promotes products as facilitating functional safety or as compliant with industry functional safety standards, such products are intended to help enable customers to design and create their own applications that meet applicable functional safety standards and requirements. Using products in an application does not by itself establish any safety features in the application. Designers must ensure compliance with safety-related requirements and standards applicable to their applications. Designer may not use any TI products in life-critical medical equipment unless authorized officers of the parties have executed a special contract specifically governing such use. Life-critical medical equipment is medical equipment where failure of such equipment would cause serious bodily injury or death (e.g., life support, pacemakers, defibrillators, heart pumps, neurostimulators, and implantables). Such equipment includes, without limitation, all medical devices identified by the U.S. Food and Drug Administration as Class III devices and equivalent classifications outside the U.S. TI may expressly designate certain products as completing a particular qualification (e.g., Q100, Military Grade, or Enhanced Product). Designers agree that it has the necessary expertise to select the product with the appropriate qualification designation for their applications and that proper product selection is at Designers’own risk. Designers are solely responsible for compliance with all legal and regulatory requirements in connection with such selection. Designer will fully indemnify TI and its representatives against any damages, costs, losses, and/or liabilities arising out of Designer’s non- compliance with the terms and provisions of this Notice. Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2018, Texas Instruments Incorporated