3.3V ADC TEMPERATURE RH I2C Registers Logic HDC1050 SDA SCL OTP Calibration Coefficients VDD GND 3.3V VDD 3.3V Product Folder Sample & Buy T echnical Documents Tools & Software Support & Community Reference Design HDC1050 SNAS658C –MAY 2015–REVISED DECEMBER 2015 HDC1050LowPower,HighAccuracyDigitalHumiditySensorwithTemperatureSensor

1 Features 3 Description

The HDC1050 is a digital humidity sensor with 1• Relative Humidity Accuracy ±3% (typical) integrated temperature sensor that provides excellent• Temperature Accuracy ±0.2°C (typical) measurement accuracy at very low power. The

  • 14 Bit Measurement Resolution HDC1050 operates over a wide supply range, and is a low cost, low power alternative to competitive• 100 nA Sleep Mode Current solutions in a wide range of common applications.• Average Supply Current: The humidity and temperature sensors are factory – 710 nA @ 1sps, 11 bit RH Measurement calibrated. – 1.3 µA @ 1sps, 11 bit RH and Temperature Device Information (1) Measurement PART• Supply Voltage 2.7 V to 5.5 V PACKAGE BODY SIZE (NOM)NUMBER
  • Small 3 mm x 3 mm Device Footprint HDC1050 PWSON (6-pin) DMB 3.00 mm x 3.00 mm
  • I2C Interface (1) For all available packages, see the orderable addendum at the end of the datasheet.

2 Applications

  • HVAC
  • Smart Thermostats and Room Monitors
  • White Goods
  • Printers
  • Handheld Meters
  • Medical Devices
  • Wireless Sensor (TIDA-00374)

4 Typical Application

An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications, intellectual property matters and other important disclaimers. PRODUCTION DATA.

SNAS658C –MAY 2015–REVISED DECEMBER 2015 www.ti.com Table of Contents

5 Revision History

NOTE: Page numbers for previous revisions may differ from page numbers in the current version. Changes from Revision B (July 2015) to Revision C Page Changes from Revision A (July 2015) to Revision B Page Changes from Original (July 2015) to Revision A Page

2 Submit Documentation Feedback Copyright © 2015, Texas Instruments Incorporated

Product Folder Links: HDC1050

www.ti.com SNAS658C –MAY 2015–REVISED DECEMBER 2015

6 Pin Configuration and Functions

6 Pin PWSON

I/O TYPE(1) DESCRIPTION NAME NO. SDA 1 I/O Serial data line for I2C, open-drain; requires a pull-up resistor to VDD GND 2 G Ground NC 3,4 - These pins may be left floating, or connected to GND VDD 5 P Supply Voltage SCL 6 I Serial clock line for I2C, open-drain; requires a pull-up resistor to VDD DAP DAP G Die Attach Pad. Should be left floating. (On bottom of the device, not shown in the figure) (1) P=Power, G=Ground, I=Input, O=Output Copyright © 2015, Texas Instruments Incorporated Submit Documentation Feedback 3 Product Folder Links: HDC1050

SNAS658C –MAY 2015–REVISED DECEMBER 2015 www.ti.com

7 Specifications

7.1 Absolute Maximum Ratings(1)

VDD -0.3 6 Input Voltage SCL -0.3 6 V SDA -0.3 6 Storage Temperature TSTG -65 150 °C (1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.

7.2 ESD Ratings

Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1) ±2000 V(ESD) Electrostatic discharge VCharged-device model (CDM), per JEDEC specification JESD22- ±500C101(2) (1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process. (2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.

7.3 Recommended Operating Conditions

over operating range (unless otherwise noted) MIN NOM MAX UNIT VDD Supply Voltage 2.7 3 5.5 V TA, Temperature sensor Ambient Operating Temperature -40 125 °C TA, Humidity sensor Ambient Operating Temperature -20 60 °C

7.4 Thermal Information

THERMAL METRIC(1) PWSON UNIT DMB 6 PINS RθJA Junction-to-Ambient Thermal Resistance 49.4 °C/W (1) For more information about traditional and new thermal metrics, see the: IC Package Thermal Metrics application report, SPRA953.

4 Submit Documentation Feedback Copyright © 2015, Texas Instruments Incorporated

Product Folder Links: HDC1050

www.ti.com SNAS658C –MAY 2015–REVISED DECEMBER 2015

7.5 Electrical Characteristics(1)

The electrical ratings specified in this section apply to all specifications in this document, unless otherwise noted. TA = 30°C, RH = 40%, and VDD = 3V. PARAMETER TEST CONDITION(2) MIN(3) TYP(4) MAX(3) UNIT POWER CONSUMPTION IDD Supply Current RH measurement, bit 12 of 0x02 register = 190 220 µA 0(5) Temperature measurement, bit 12 of 0x02 160 185 µA register = 0(5) Sleep Mode 100 200 nA Average @ 1 measurement/second, RH (11 710 nA bit), bit 12 of 0x02 register = 0(5)(6) Average @ 1 measurement/second, Temp 590 nA (11 bit), bit 12 of 0x02 register = 0(5)(6) Average @ 1 measurement/second, RH 1.3 µA (11bit) +temperature (11 bit), bit 12 of 0x02 register = 1(5)(6) Startup (average on Start-up time) 300 µA IHEAT Heater Current(7) Peak current 7.2 mA Average @ 1 measurement/second, RH 50 µA (11bit) +temperature (11 bit), bit 12 of 0x02 register = 1(5)(6) RELATIVE HUMIDITY SENSOR RHACC Accuracy Refer to Figure 2 in Typical Characteristics ±3 %RH section. RHREP Repeatability(7) 14 bit resolution ±0.1 %RH RHHYS Hysteresis (8) 20% ≤ RH ≤ 60% ±1 %RH RHRT Response Time(9) t 63% (10) 30 s RHCT Conversion Time(7) 8 bit resolution 2.50 ms 11 bit resolution 3.85 ms 14 bit resolution 6.50 ms RHOR Operating Range(11) Non-condensing 0 100 %RH RHLTD Long Term Drift ±0.5 %RH/yr TEMPERATURE SENSOR TEMPACC Accuracy(7) 5°C < TA< 60°C ±0.2 ±0.4 °C TEMPREP Repeatability(7) 14 bit resolution ±0.1 °C TEMPCT Conversion Time(7) 11 bit accuracy 3.65 ms 14 bit accuracy 6.35 ms (1) Electrical Characteristics Table values apply only for factory testing conditions at the temperature indicated. Factory testing conditions result in very limited self-heating of the device such that TJ = TA. No guarantee of parametric performance is indicated in the electrical tables under conditions of internal self-heating where TJ > TA. Absolute Maximum Ratings indicate junction temperature limits beyond which the device may be permanently degraded, either mechanically or electrically. (2) Register values are represented as either binary (b is the prefix to the digits), or hexadecimal (0x is the prefix to the digits). Decimal values have no prefix. (3) Limits are ensured by testing, design, or statistical analysis at 30°C. Limits over the operating temperature range are ensured through correlations using statistical quality control (SQC) method. (4) Typical values represent the most likely parametric norm as determined at the time of characterization. Actual typical values may vary over time and will also depend on the application and configuration. The typical values are not tested and are not guaranteed on shipped production material. (5) I2C read/write communication and pull-up resistors current through SCL and SDA not included. (6) Average current consumption while conversion is in progress. (7) This parameter is specified by design and/or characterization and it is not tested in production. (8) The hysteresis value is the difference between an RH measurement in a rising and falling RH environment, at a specific RH point. (9) Actual response times will vary dependent on system thermal mass and air-flow. (10) Time for the RH output to change by 63% of the total RH change after a step change in environmental humidity. (11) Recommended humidity operating range is 20% to 60% RH. Prolonged operation outside this range may result in a measurement offset. The measurement offset will decrease after operating the sensor in this recommended operating range. Copyright © 2015, Texas Instruments Incorporated Submit Documentation Feedback 5 Product Folder Links: HDC1050

7.6 I2C Interface Electrical Characteristics

(1) This parameter is specified by design and/or characterization and it is not tested in production.

7.7 I2C Interface Timing Requirements

(1) This parameter is specified by design and/or characterization and it is not tested in production. (2) Within this interval it is not possible to communicate to the device. Figure 1. I2C Timing

6 Submit Documentation Feedback Copyright © 2015, Texas Instruments Incorporated

7.8 Typical Characteristics

Unless otherwise noted. TA = 30°C, VDD = 3V. Figure 2. RH Accuracy vs. RH Figure 3. Temperature Accuracy vs. Temperature Figure 4. Supply Current vs. Supply Voltage, RH Figure 5. Supply Current vs. Temperature, RH Measurement Figure 6. Supply Current vs. Supply Voltage, Temp Figure 7. Supply Current vs. Temperature, Temp

Unless otherwise noted. TA = 30°C, VDD = 3V. Figure 8. Supply Current vs. Supply Voltage, Sleep Mode Figure 9. Supply Current vs. Temperature, Sleep Mode

8 Submit Documentation Feedback Copyright © 2015, Texas Instruments Incorporated

www.ti.com SNAS658C –MAY 2015–REVISED DECEMBER 2015

8 Detailed Description

8.1 Overview

The HDC1050 is a digital humidity sensor with integrated temperature sensor that provides excellent measurement accuracy at very low power. The sensing element of the HDC1050 is placed on the top part of the device. Measurement results can be read out through the I2C compatible interface. Resolution is based on the measurement time and can be 8, 11, or 14 bits for humidity; 11 or 14 bits for temperature.

8.2 Functional Block Diagram

8.3 Feature Description

8.3.1 Power Consumption

One of the key features of the HDC1050 is its low power consumption, which makes the device suitable in battery or power harvesting applications. In these applications the HDC1050 spends most of the time in sleep mode: with a typical 100nA of current consumption in sleep mode, the averaged current consumption is minimal. Its low consumption in measurement mode minimizes any self-heating.

8.3.2 Voltage Supply Monitoring

The HDC1050 monitors the supply voltage level and indicates when the voltage supply of the HDC1050 is less than 2.8V. This information is useful in battery-powered systems in order to inform the user to replace the battery. This is reported in the BTST field (register address 0x02:bit[11]) which is updated after POR and after each measurement request.

8.3.3 Heater

The heater is an integrated resistive element that can be used to test the sensor or to drive condensation off the sensor. The heater can be activated using HEAT, bit 13 in the Configuration Register. The heater helps in reducing the accumulated offset after long exposure at high humidity conditions. Once enabled the heater is turned on only in the measurement mode. To accelerate the temperature increase it is suggested to increase the measurement data rate.

8.4 Device Functional Modes

The HDC1050 has two modes of operation: sleep mode and measurement mode. After power up, the HDC1050 is in sleep mode. In this mode, the HDC1050 waits for I2C input including commands to configure the conversion times, read the status of the battery, trigger a measurement, and read measurements. Once it receives a command to trigger a measurement, the HDC1050 moves from sleep mode to measurement mode. After completing the measurement the HDC1050 returns to sleep mode. Copyright © 2015, Texas Instruments Incorporated Submit Documentation Feedback 9 Product Folder Links: HDC1050

8.5 Programming

8.5.1 I2C Interface

communication or measurement is performed. All data bytes are transmitted MSB first.

8.5.1.1 Serial Bus Address

or write operation. The I2C address of the HDC1050 is 1000000 (7-bit address).

8.5.1.2 Read and Write Operations

To access a particular register on the HDC1050, write the desired register address value to the Pointer Register. operation to the HDC1050 requires a value for the pointer register (refer to Figure 10). the R/W bit low, followed by the pointer byte. No additional data is required (refer to Figure 11). incorrect I2C address returns a NACK after the I2C address. Figure 10. Writing Frame (Configuration Register)

10 Submit Documentation Feedback Copyright © 2015, Texas Instruments Incorporated

Figure 11. Reading Frame (Configuration Register)

8.5.1.3 Device Measurement Configuration

  1. Configure the acquisition parameters in register address 0x02:

(a) Set the acquisition mode to measure both temperature and humidity by setting Bit[12] to 1. – Set Bit[10] to 0 for 14 bit resolution. – Set Bit[10] to 1 for 11 bit resolution. – Set Bit[9:8] to 00 for 14 bit resolution. – Set Bit[9:8] to 01 for 11 bit resolution. – Set Bit[9:8] to 10 for 8 bit resolution.

  1. Trigger the measurements by executing a pointer write transaction with the address pointer set to 0x00.
  2. Wait for the measurements to complete, based on the conversion time (refer to Electrical Characteristics(1)

registers have not been updated as shown in Figure 13. To perform another acquisition with the same measurement configuration simply repeat steps 2 through 4.

  1. Configure the acquisition parameters in register address 0x02:

(a) Set the acquisition mode to independently measure temperature or humidity by setting Bit[12] to 0. – Set Bit[10] to 0 for 14 bit resolution. which the device may be permanently degraded, either mechanically or electrically.

– Set Bit[10] to 1 for 11 bit resolution. – Set Bit[9:8] to 00 for 14 bit resolution. – Set Bit[9:8] to 01 for 11 bit resolution. – Set Bit[9:8] to 10 for 8 bit resolution.

  1. Trigger the measurement by executing a pointer write transaction. Refer to Figure 12

– Set the address pointer to 0x00 for a temperature measurement. – Set the address pointer to 0x01 for a humidity measurement.

  1. Wait for the measurement to complete, based on the conversion time (refer to Electrical Characteristics(1) for

Figure 11. A read operation will return a NACK if the measurement result is not yet available, as shown in To perform another acquisition with the same measurement configuration repeat steps 2 through 4. measurement is ongoing will abort the ongoing measurement. Figure 12. Trigger Humidity/Temperature Measurement Figure 13. Read Humidity/Temperature Measurement (Data Not Ready)

12 Submit Documentation Feedback Copyright © 2015, Texas Instruments Incorporated

Figure 14. Read Humidity and Temperature Measurement (Data Ready)

8.6 Register Map

measurement results, and status information. Table 1. Register Map Registers addresses 0x03 to 0xFA are reserved and should not be written. command. The power-on reset (POR) value of the pointer is 0x00, which selects a temperature measurement.

8.6.1 Temperature Register

Table 2. Temperature Register Description (0x00) which the device may be permanently degraded, either mechanically or electrically.

8.6.2 Humidity Register

Table 3. Humidity Register Description (0x01) which the device may be permanently degraded, either mechanically or electrically.

14 Submit Documentation Feedback Copyright © 2015, Texas Instruments Incorporated

8.6.3 Configuration Register

This register configures device functionality and returns status. Table 4. Configuration Register Description (0x02)

1 Heater Enabled

MODE [12] Mode of 0 Temperature or Humidity is acquired. acquisition 1 Temperature and Humidity are acquired in sequence, Temperature first.

8.6.4 Serial Number Registers

These registers contain a 40bit unique serial number for each individual HDC1050. Table 5. Serial Number Register Description (0xFB) Table 6. Serial Number Register Description (0xFC) Table 7. Serial Number Register Description (0xFD)

8.6.5 Manufacturer ID Register

same I2C bus. The manufacturer ID reads 0x5449. Table 8. Manufacturer ID Register Description (0xFE)

8.6.6 Device Register ID

Table 9. Device ID Register Description (0xFF)

16 Submit Documentation Feedback Copyright © 2015, Texas Instruments Incorporated

9 Application and Implementation

validate and test their design implementation to confirm system functionality.

9.1 Application Information

system. The collected data are then shown on a display that can be easily controlled by the micro controller. environment at customer-defined preferred conditions.

9.2 Typical Application

Figure 15. Typical Application Schematic HVAC

9.2.1 Design Requirements

9.2.2 Detailed Design Procedure

When a circuit board layout is created from the schematic shown in Figure 15 a small circuit board is possible. HDC1050, which can improve measurement response time and accuracy.

9.2.3 Application Curve

Figure 16. RH vs. Time

9.3 Do's and Don'ts

9.3.1 Soldering

soldering profile according to IPC/JEDEC J-STD-020 with peak temperatures at 260 °C. When soldering the HDC1050 it is mandatory to use no-clean solder paste and no board wash shall be applied. The HDC1050 should be limited to a single IR reflow and no rework is recommended.

9.3.2 Hydration Procedure

  • Store the PCB containing the HDC1050 at 85% RH and 85 °C for 12 hours.

9.3.3 Chemical Exposure and Sensor Protection

circuit board, the sensor must be protected during the coating process.

18 Submit Documentation Feedback Copyright © 2015, Texas Instruments Incorporated

10 Power Supply Recommendations

0.1µF between the VDD and GND pins is recommended.

11 Layout

11.1 Layout Guidelines

The Relative Humidity sensor element is located on the top side of the package. (GND, VDD) and creating a slot into the PCB around the sensor to enhance thermal isolation.

11.2 Layout Example

board pad should NOT be connected to GND. Figure 17. Layout

SNAS658C –MAY 2015–REVISED DECEMBER 2015 www.ti.com

12 Device and Documentation Support

12.1 Documentation Support

12.1.1 Related Documentation

Texas Instruments Humidity Sensors, SNAA216, provides a general description of humidity sensing and important design guidelines.

12.2 Community Resources

The following links connect to TI community resources. Linked contents are provided "AS IS" by the respective contributors. They do not constitute TI specifications and do not necessarily reflect TI's views; see TI's Terms of Use. TI E2E™ Online Community TI's Engineer-to-Engineer (E2E) Community. Created to foster collaboration among engineers. At e2e.ti.com, you can ask questions, share knowledge, explore ideas and help solve problems with fellow engineers. Design Support TI's Design Support Quickly find helpful E2E forums along with design support tools and contact information for technical support.

12.3 Trademarks

E2E is a trademark of Texas Instruments. All other trademarks are the property of their respective owners.

12.4 Electrostatic Discharge Caution

These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates.

12.5 Glossary

SLYZ022 — TI Glossary. This glossary lists and explains terms, acronyms, and definitions.

13 Mechanical, Packaging, and Orderable Information

The following pages include mechanical, packaging, and orderable information. This information is the most current data available for the designated devices. This data is subject to change without notice and revision of this document. For browser-based versions of this data sheet, refer to the left-hand navigation.

20 Submit Documentation Feedback Copyright © 2015, Texas Instruments Incorporated

Product Folder Links: HDC1050

www.ti.com 3-Feb-2016 Addendum-Page 1 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Drawing Pins Package Qty Eco Plan (2) Lead/Ball Finish (6) MSL Peak Temp (3) Op Temp (°C) Device Marking (4/5) Samples HDC1050DMBR NRND WSON DMB 6 3000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM -40 to 125 FE HDC1050DMBT NRND WSON DMB 6 250 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM -40 to 125 FE (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. (4) There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device. (5) Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation of the previous line and the two combined represent the entire Device Marking for that device. (6) Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish value exceeds the maximum column width. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.

www.ti.com 3-Feb-2016 Addendum-Page 2 In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.

Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily performed. TI assumes no liability for applications assistance or the design of Buyers’products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers’products and applications, Buyers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use of any TI components in safety-critical applications. In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and requirements. Nonetheless, such components are subject to these terms. No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties have executed a special agreement specifically governing such use. Only those TI components which TI has specifically designated as military grade or “enhanced plastic”are designed and intended for use in military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of non-designated products, TI will not be responsible for any failure to meet ISO/TS16949. Products Applications Audio www.ti.com/audio Automotive and Transportation www.ti.com/automotive Amplifiers amplifier.ti.com Communications and Telecom www.ti.com/communications Data Converters dataconverter.ti.com Computers and Peripherals www.ti.com/computers DLP® Products www.dlp.com Consumer Electronics www.ti.com/consumer-apps DSP dsp.ti.com Energy and Lighting www.ti.com/energy Clocks and Timers www.ti.com/clocks Industrial www.ti.com/industrial Interface interface.ti.com Medical www.ti.com/medical Logic logic.ti.com Security www.ti.com/security Power Mgmt power.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video RFID www.ti-rfid.com OMAP Applications Processors www.ti.com/omap TI E2E Community e2e.ti.com Wireless Connectivity www.ti.com/wirelessconnectivity Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2016, Texas Instruments Incorporated