Technical content
Fully signal conditioned pressure transducer January 1998/026 Aubinger Weg 27, 82178 Puchheim, Germany Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com
FEATURES
- Pressure ranges from ±5 mbar to 5 bar differential, 1 and 2 bar absolute
- TTL power supply
- 0.5 to 4.5 V output
- Inline pinning for easy PCB-mounting
- Externally adjustable offset and span SPECIFICATIONS Maximum ratings Excitation voltage Output current Source Sink Temperature limits Operating Storage Compensated Humidity Proof pressure HCXM050 to HCXM350 all HCX... ELECTRICAL CONNECTION
4.8 V to 15 V
-20°C to 70°C -20°C to 85°C 0°C to 50°C 0 - 95 %RH 350 mbar 1.4 bar 2 x rated pressure SERVICE Non-corrosive, non-ionic working fluids, such as dry air and dry gases. Scale: 1cm 1 inch
Fully signal conditioned pressure transducer January 1998/026 Aubinger Weg 27, 82178 Puchheim, Germany Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com OUTLINE DRAWING P1: High pressure port for 5 mbar and 10 mbar devices P2: High pressure port for all other devices. Mass: 14 g PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 5 V, RL > 100 kΩΩΩΩΩ , tamb = 25°C) Min. -10 2.40 0.40 0.45 3.95 Typ. 2.50 0.50 0.5 4.0 4.5 0.5 0.5 0.1 ±0.2 0.05 0.03 Max. 100 350 1000 2000 5000 2.60 0.60 0.55 4.05 1.0 0.5 0.20 0.12 0.10 0.05 Unit mbar V %FSO %FSO/°C Ω %FSO %FSO/V mW Characteristics Operating pressure HCXPM005D6... HCXM010D6... HCXPM010D6... HCXM020D6... HCXM050D6... HCXM100D6... HCXM350D6... Zero pressure offset all HCXPM... HCXM010D6/HCXM020D6... all other devices Span Full scale output Output at lowest specified pressureHCXPM... only Non-linearity and hysteresis (BSL) 2 HCXM020D6... all other devices Thermal effects (0 to 50°C) Combined offset and span HCXM100D6... all other devices Output impedance Long term stability Power supply rejection Offset Span Power consumption
Fully signal conditioned pressure transducer January 1998/026 Aubinger Weg 27, 82178 Puchheim, Germany Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com OUTLINE DRAWING HCX(M)...6V P1: High pressure port for 5 mbar and 10 mbar devices P2: High pressure port for all other devices. Mass: 14 g All dimensions in mm
ORDERING INFORMATION
Differential / gage devices 0 to ±5 mbar 0 to 10 mbar 0 to ±10 mbar 0 to 20 mbar 0 to 50 mbar 0 to 100 mbar 0 to 350 mbar 0 to 1 bar 0 to 2 bar 0 to 5 bar Absolute devices 0 to 1 bar 0 to 2 bar Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. Non-linearity - the maximum deviation of measured output at constant temperature, from "Best Straight Line" through three points (offset pressure, full scale pressure and 1/2 full scale pressure). Change after one year or 1 million pressure cycles. Thermal effects tested and guaranteed from 0°C to 50°C relative to 25°C. All specifications shown are relative to 25°C. Span is the algebraic difference between the output at full scale pressure and offset. Offset adjustment possible to lower values only. Do not trim for nominal value minus 150 mV. Span adjustment possible to lower pressure range (higher gain). Do not trim for more than 15% of full scale pressure Specification Notes