HCS2-150-F HIROSE | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
RF Coaxial Switches (DC to 15 GHz) HCS2 Series Item ConditionsStandard I Features 1.High Performance and High Reliability These switches are of the SPDT fail-safe type and have been designed for wide frequency bandwidth, contact voltage strength, power saving, and vibration resistance. 2.SMA Connections SMA type coupling (Hirose Electric HRM Series) has been used. 3.Environmentally Rugged A wide variety of tests including temperature and humidity cycles, high temperature power, low temperature power, humidity,vibration, and shock have been conducted and good results were obtained for all. I Product Specifications Ratings 0ç to +50ç (No freezing) 90% Max. Operating temperature range Operating relative humidity DC to 15 GHz 50 ohms 15 W Frequency range Characteristic impedance Maximum Input Power 1.Contact resistance 1 A DCVoltage drop of 4 mV max. 2.Insulation resistance 500 V DC5000 M ohms Min. 3.Withstanding voltage 100 V AC/one minuteNo flashover or insulation breakdown 4.Vibration Frequency of 10 to 55 Hz, overall amplitude of 1.52 mm for 2 hours in ech of 3 directions, Frequency of 10 to 500 Hz, acceleration of 49 m/s2 for 3 hours in each of 3 directionsNo electrical discontinuity of 1 µs or more No damage, cracks, or parts dislocation5.Shock Acceleration of 490 m/s 2, sine half-wave waveform, 6 cycles in each of the 3 axis 6.Humidity 240 hours at temperature of 40ç and humidity of 95% Insulation resistance: 1000 M ohms min. No damage, cracks, or parts dislocation 7.Temperature cycle Temperature: -30ç¡ +5ç to +35ç¡ +65ç¡ +5ç to +35ç Time: 30¡ 5 max.¡ 30¡ 5 max. (Minutes) 5 cycles No damage, cracks, or parts dislocation G The test method conforms to JIS. G The temperature resistance cycle, humidity resistance, and shock resistance tests are verification tests of part deterioration and looseness, not tests to be conducted at time of switching or when conducting. I Materials I Ordering Information Part Material Finish Outer conductor Aluminum Conductive alumite Inner conductor Beryllium copper Gold plating Connector Body Stainless steel Passivated Female contact Beryllium copper Gold plating Case Aluminum Black alumite HCS 2 - 1 1 0 - F qw e r t y qSeries Name: HCS wSeries No: 2 rSwitching Voltage 1: 12V 4: 17V 2: 20V 5: 10V 3: 26V eType of Connector 1: SMA (Hirose Electric HRM Series) tPresence of Auxiliary Contacts 0: No 1: Yes yOperation Method F: Fail-safe type
V.S.W.R. (Max) DC ~00.4GHz 4~00.8GHz 8~12.4GHz 12.4~0.15GHz I Specifications Part Number Frequency Range (GHz) Insertion Loss (Max) (dB) DC ~00.4GHz 4~00.8GHz 8~12.4GHz 12.4~0.15GHz Isolation (Min) (dB) Power (W) Heat Sink Temperature at Applicable Voltage (ç Max) RMS Voltage Rating Peak (V) Switching Time (ms) Switching Volt Current Durability (Insertion/withdrawal) Connectors Type of Switch Operation Auxiliary contact point Weight (g) G The value of the switching current is the maximum value at 20ç. 1.20 1.25 1.40 1.50 HCS2-111-FHCS2-150-F DC ~15 0.2 0.3 0.4 0.5 +50 300 DC11 ~14V 120mA Max DC9 ~11V 250mA Max 1000030000 HRM-J SPDT fail-safe withwithout HCS2-110-F DC11 ~14V 120mA Max 30000 without HCS2-140-F DC15 ~19V 150mA Max 30000 without HCS2-121-F DC18 ~24.5V 120mA Max 10000 with HCS2-120-F DC18 ~24.5V 120mA Max 30000 without HCS2-131-F DC24 ~30V 70mA Max 10000 with HCS2-130-F DC24 ~30V 70mA Max 30000 without G The HCS2 Series is of the fail safe type and designed to make contact by spring force when the drive voltage is not applied. The application of vibrations or shocks in excess of the spring limit may cause resonance of the spring which results in a loss of contact stability and intermittent contact. G The construction does not prevent the effects of humidity, pressure, or the atmosphere (i.e., gases, oils, and liquids). (Gases, depending on type, may penetrate the spring material inside. The penetration of gases, oils, or liquids that form a film on the contacts may causes changes of the insulation or may cause the contacts to cease to conduct.) G This product is not magnetically shielded and as such the attention must be paid to the following points. (1) The plate used to mount this product should be made of non-magnetic material. (Aluminum plate is preferable.) (2) Avoid the use of magnetic material and anything that may produce a magnetic field such as a magnet in the proximity of the switches (roughly a 15 mm square). I Precautions
I Circuit Diagram I Typical Data 110 120 130 140 150 111 121 131 HCS2 ----- ----- F HCS2 ----- ----- F 110 120 130 140 150 111 121 131 When Switching Signal is OFF Switching signal Auxiliary contacts Switching signal Coaxial connectors Coaxial connectors