Features
- Low power consumption
- High speed: 1 Mb/s
- LVTTL/LVCMOS compatible
- Available in 8-pin DIP, SO-8
- Open collector output
- Guaranteed performance from temperature: 0˚C to +70˚C
- Safety approval, UL, CSA, IEC/EN/DIN EN 60747-5-2
Applications
- High voltage insulation
- Video signal isolation
- Power translator isolation in motor drives
- Line receivers
- Feedback element in switched mode power supplies
- High speed logic ground isolation – LVTTL/LVCMOS
- Replaces pulse transformers
- Replaces slow phototransistor isolators
- Analog signal ground isolation Functional Diagram A 0.1 µF bypass capacitor must be connected between pins 5 and 8. CAUTION: It is advised that normal static precautions be taken in handling and assembly of this component to prevent damage and/or degradation which may be induced by ESD. These optocouplers are available in an 8-pin DIP and in an industry standard SO-8 package. The following is a cross reference table listing the 8-pin DIP part number and the electrically equivalent SO-8 part number. The SO-8 does not require "through holes" in a PCB. This package occupies approximately one-third the footprint area of the 4 5 8ANODE 1 CATHODE 1 CATHODE 2 ANODE 2 VCC VO1 VO2 GND HCPL–253L/HCPL–053L 4 5 8NC ANODE CATHODE NC VCC VB VO GND TRUTH TABLE (POSITIVE LOGIC) LED ON OFF VO LOW HIGH HCPL–250L/HCPL–050L
Ordering Information
Specify Part Number followed by Option Number (if desired). Example: HCPL-250L #XXXX 060 = IEC/EN/DIN EN 60747-5-2 VIORM 500 = Tape and Reel Packaging Option XXXE = Lead Free Option Option data sheets available. Contact Agilent sales representative or authorized distributor for information. Schematic standard dual-in-line package. The lead profile is designed to be compatible with standard surface mount processes. These optocouplers can be used in LVTTL/LVCMOS or wide bandwidth analog applications. The common mode transient immunity of 1000 V/µs minimum to typical at V CM = 10 V guaranteed for these optocouplers. 8-Pin DIP SO-8 Package HCPL-250L HCPL-050L HCPL-253L HCPL-053L IF1 SHIELD VCC VO1 ICC VF1 IO1 IF2 GND VO2 VF2 IO2 IF SHIELD GND VCC VO ICC VF IO ANODE CATHODE VB IB HCPL-250L/HCPL-050L HCPL-253L/HCPL-053L Remarks: The notation “#” is used for existing products, while (new) products launched since 15th July 2001 and lead free option will use “-”
1.080 ± 0.320 (0.043 ± 0.013) 2.54 ± 0.25 (0.100 ± 0.010) 0.51 (0.020) MIN. 0.65 (0.025) MAX. 4.70 (0.185) MAX. 2.92 (0.115) MIN. 5° TYP. 0.254+ 0.076 - 0.051 (0.010+ 0.003) - 0.002) 7.62 ± 0.25 (0.300 ± 0.010) 6.35 ± 0.25 (0.250 ± 0.010) 9.65 ± 0.25 (0.380 ± 0.010) A XXXXZ YYWW DATE CODE DIMENSIONS IN MILLIMETERS AND (INCHES). 5678 4321 OPTION CODE* UL RECOGNITION UR TYPE NUMBER * MARKING CODE LETTER FOR OPTION NUMBERS "V" = OPTION 060 OPTION NUMBERS 300 AND 500 NOT MARKED. NOTE: FLOATING LEAD PROTRUSION IS 0.25 mm (10 mils) MAX. 3.56 ± 0.13 (0.140 ± 0.005) Small Outline SO-8 Package XXXV YWW 8765 4321 5.994 ± 0.203 (0.236 ± 0.008) 3.937 ± 0.127 (0.155 ± 0.005) 0.406 ± 0.076 (0.050)BSC 5.080 ± 0.127 (0.200 ± 0.005) 3.175 ± 0.127 (0.060) 45° X 0.432 (0.017) 0.228 ± 0.025 (0.009 ± 0.001) TYPE NUMBER (LAST 3 DIGITS) DATE CODE 0.305 (0.012)MIN. TOTAL PACKAGE LENGTH (INCLUSIVE OF MOLD FLASH) DIMENSIONS IN MILLIMETERS (INCHES). LEAD COPLANARITY = 0.10 mm (0.004 INCHES) MAX. OPTION NUMBER 500 NOT MARKED. NOTE: FLOATING LEAD PROTRUSION IS 0.15 mm (6 mils) MAX. 0.203 ± 0.102 (0.008 ± 0.004) PIN ONE 0 ~ 7° 7.49 (0.295) 1.9 (0.075) 0.64 (0.025) LAND PATTERN RECOMMENDATION
Solder Reflow Temperature Profile Regulatory Information The devices contained in this data sheet have been approved by the following organizations: UL Approval under UL 1577, Component Recognition Program, File E55361. CSA Approval under CSA Component Acceptance Notice #5, File CA 88324. IEC/EN/DIN EN 60747-5-2 Approved under: IEC 60747-5-2:1997 + A1:2002 EN 60747-5-2:2001 + A1:2002 DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01 Recommended Pb-Free IR Profile TIME (SECONDS) TEMPERATURE ( °C)200 100 50 150 100 200 250 300 SEC. 50 SEC. SEC. 160°C 140°C 150°C PEAK TEMP. 245°C PEAK TEMP. 240°C PEAK TEMP. 230°C SOLDERING TIME 200°C PREHEATING TIME 150°C, 90 + 30 SEC. 2.5°C ± 0.5°C/SEC. 3°C + 1°C/–0.5°C TIGHT TYPICAL LOOSE ROOM TEMPERATURE PREHEATING RATE 3 °C + 1°C/–0.5°C/SEC. REFLOW HEATING RATE 2.5 °C ± 0.5°C/SEC. 217 °C RAMP-DOWN 6 °C/SEC. MAX. RAMP-UP 3 °C/SEC. MAX. 150 - 200 °C 260 +0/-5 °C t 25 °C to PEAK 60 to 150 SEC. 20-40 SEC. TIME WITHIN 5 °C of ACTUAL PEAK TEMPERATURE tp ts PREHEAT 60 to 180 SEC. tL TL Tsmax Tsmin Tp TIME TEMPERATURE NOTES: THE TIME FROM 25 °C to PEAK TEMPERATURE = 8 MINUTES MAX. Tsmax = 200 °C, Tsmin = 150 °C
Insulation and Safety Related Specifications 8-Pin DIP (300 Mil) SO-8 Parameter Symbol V alue Value Units Conditions Minimum External Air L (101) 7.1 4.9 mm Measured from input terminals to output Gap (External Clearance) terminals, shortest distance through air. Minimum External Tracking L (102) 7.4 4.8 mm Measured from input terminals to output (External Creepage) terminals, shortest distance path along body. Minimum Internal Plastic 0.08 0.08 mm Through insulation distance, conductor to Gap (Internal Clearance) conductor, usually the direct distance between the photoemitter and photodetector inside the optocoupler cavity. Tracking Resistance CTI 200 200 Volts DIN IEC 112/VDE 0303 Part 1 (Comparative Tracking Index) Isolation Group IIIa IIIa Material Group (DIN VDE 0110, 1/89, Table 1) IEC/EN/DIN EN 60747-5-2Insulation Related Characteristics Description Symbol PDIP Option 060 SO-8 Option 60 Units Installation classification per DIN VDE 0110/1.89, Table 1 for rated mains voltage ≤ 150 V rms I-IV for rated mains voltage ≤ 300 V rms I-IV I-III for rated mains voltage ≤ 600 V rms I-III I-II Climatic Classification 55/85/21 55/85/21 Pollution Degree (DIN VDE 0110/1.89) 2 2 Maximum Working Insulation Voltage V IORM 630 566 V peak Input to Output Test Voltage, Method b* VIORM x 1.875 = V PR, 100% Production Test V PR 1181 1063 V peak with tm = 1 sec, Partial Discharge < 5 pC Input to Output Test Voltage, Method a* VIORM x 1.5 = V PR, Type and Sample Test, V PR 945 849 V peak tm = 60 sec, Partial Discharge < 5 pC Highest Allowable Overvoltage* V IOTM 6000 4000 V peak (Transient Overvoltage, t ini = 10 sec) Safety Limiting Values (Maximum values allowed in the event of a failure, also see Figure 16, Thermal Derating curve.) Case Temperature T S 175 150 ˚C Input Current I S,INPUT 230 150 mA Output Power P S,OUTPUT 600 600 mW Insulation Resistance at T S, VIO = 500 V R S ≥ 109 ≥ 109 Ω *Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-2, for a detailed description. Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits i n application.
Parameter Symbol Min. Max. Units Note Storage Temperature T S –55 125 °C Operating Temperature T A –55 100 °C –55 85 Average Forward Input Current I F(AVG) 25 mA 1 Peak Forward Input Current I F(PEAK) 2 (50% duty cycle, 1 ms pulse width) 50 mA (50% duty cycle, 1 ms pulse width) 40 Peak Transient Input Current I F(TRANS) 1A (≤ 1 µs pulse width, 300 pps) 0.1 Reverse LED Input Voltage (Pin 3-2) V R 5V Input Power Dissipation P IN 45 mW 3 Average Output Current (Pin 6) I O(AVG) 8m A Peak Output Current I O(PEAK) 16 mA Emitter-Base Reverse Voltage V EBR 5V Supply Voltage (Pin 8-5) V CC –0.5 7 V Output Voltage (Pin 6-5) V O –0.5 7 V Base Current I B 5m A Output Power Dissipation P O 100 mW 4 Lead Solder Temperature (Through Hole Parts Only) 1.6 mm below seating plane, 10 sec. T LS 260 °C up to seating plane, 10 seconds 260 °C Reflow Temperature Profile T RP See Package Outline Drawings section Recommended Operating Conditions Parameter Symbol Min. Max. Units Power Supply Voltage V CC 2.7 3.6 V Forward Input Current I F(ON) 16 20 mA Forward Input Voltage V F(OFF) 00 . 8 V Operating Temperature T A 08 5 °C
Electrical Specifications (DC) Over Recommended Temperature (T A = 0˚C to +70˚C), VCC = 3.3 V, I F = 16 mA, unless otherwise specified. See Note 13. Current Transfer CTR % T A = 25˚C V O = 0.4 V I F = 16 mA, 2 5, 11 VCC = 3.3 V 15 20 50 Logic Low V OL VI F = 16 mA, VCC = 3.3 V 0.05 0.3 T A = 25˚C I O = 3.0 mA Logic High I OH 0.003 1 µAT A = 25˚C V O = VCC = 3.3 V I F = 0 mA 3 Output Current Logic Low I CCL 43.0 100 µAI F = 16 mA, VO = Open, VCC = 3.3 V 13 Supply Current Dual 300 Logic High I CCH 0.005 0.3 µAT A = 25˚C I F = 0 mA, VO = Open, 13 Supply Current Dual 10 V CC = 3.3 V Input Forward V F 1.52 1.7 V T A = 25˚C I F = 16 mA 1 Voltage Input Reverse BV R 5V I R = 10 µA Breakdown Voltage Input C IN 60 pF f = 1 MHz, V F = 0 V Capacitance Ratio Output Voltage Switching Specifications (AC) Over Recommended Temperature (T A = 0˚C to +70˚C), VCC = 3.3 V, I F = 16 mA unless otherwise specified. All typicals at VCC = 3.3 V, TA = 25°C. Propagation t PHL 0.35 1 µsR L = 1.9 kΩ 5 8, 9 Delay Time to Logic Low at Output Propagation t PLH 0.65 1 µsR L = 1.9 kΩ 5 8, 9 Delay Time to Logic High at Output Common Mode | C MH|1 k V / µsR L = 4.1 kΩ IF = 0 mA, TA = 25˚C, 6 7, 8, 9 Transient R L = 1.9 kΩ VCM = 10 Vp-p Immunity at C L = 15 pF Logic High Level Output Common Mode | C ML|1 k V / µsR L = 4.1 kΩ IF = 16 mA, TA = 25˚C, 6 7, 8, 9 Transient R L = 1.9 kΩ VCM = 10 Vp-p Immunity at C L = 15 pF Logic Low Level Output *All typicals at T A = 25˚C
Over Recommended Temperature (T A = 0˚C to 70˚C) unless otherwise specified. Input-Output V ISO 8-Pin DIP 3750 V rms RH < 50%, 6, 14 Momentary SO-8 t = 1 min., Withstand T A = 25˚C Voltage** II-O 8-Pin DIP 1 µA 45% RH, t = 5 s, 6, 16 VI-O = 3 kVdc, TA = 25˚C Input-Output R I-O 8-Pin DIP 10 12 Ω VI-O = 500 Vdc 6 Resistance SO-8 Input-Output C I-O 8-Pin DIP 0.6 pF f = 1 MHz 6 Capacitance SO-8 *All typicals at T A = 25˚C. **The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics Table (if applicable), your equipment level safety specification or Agilent Application Note 1074 entitled "Optocoupler Input-Output Endurance Voltage ," publication number 5963-2203E. Notes: 1. Derate linearly above 70˚C free-air temperature at a rate of 0.8 mA/˚C (8-Pin DIP). Derate linearly above 85˚C free-air temperature at a rate of 0.5 mA/˚C (SO-8). 2. Derate linearly above 70˚C free-air temperature at a rate of 1.6 mA/˚C (8-Pin DIP). Derate linearly above 85˚C free-air temperature at a rate of 1.0 mA/˚C (SO-8). 3. Derate linearly above 70˚C free-air temperature at a rate of 0.9 mW/˚C (8-Pin DIP). Derate linearly above 85˚C free-air temperature at a rate of 1.1 mW/˚C (SO-8). 4. Derate linearly above 70˚C free-air temperature at a rate of 2.0 mW/˚C (8-Pin DIP). Derate linearly above 85˚C free-air temperature at a rate of 2.3 mW/˚C (SO-8). 5. CURRENT TRANSFER RATIO in percent is defined as the ratio of output collector current, I O, to the forward LED input current, I F, times 100. 6. Device considered a two-terminal device: Pins 1, 2, 3, and 4 shorted together and Pins 5, 6, 7, and 8 shorted together. 7. Common mode transient immunity in a Logic High level is the maximum tolerable (positive) dV CM/dt on the leading edge of the common mode pulse signal, V CM, to assure that the output will remain in a Logic High state (i.e., V O > 2.0 V). Common mode transient immunity in a Logic Low level is the maximum tolerable (negative) dV CM/dt on the trailing edge of the common mode pulse signal, V CM, to assure that the output will remain in a Logic Low state (i.e., V O < 0.8 V). 10. The frequency at which the AC output voltage is 3 dB below its mid-frequency value. 11. The JEDEC registration for the 6N136 specifies a minimum CTR of 15%. Agilent guarantees a minimum CTR of 15%. 12. See Option 020 data sheet for more information. 13. Use of a 0.1 µf bypass capacitor connected between pins 5 and 8 is recommended. 14. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 4500 V rms for 1 second (leakage detection current limit, I I-O ≤ 5 µA). This test is performed before the 100% Production test shown in the IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics Table, if applicable. 15. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 second (leakage detection current limit, I I-O ≤ 5 µA). This test is performed before the 100% Production test shown in the IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics Table, if applicable. 16. This rating is equally validated by an equivalent AC proof test.
Figure 3. Logic high output current vs.
8 PIN DIP, SO-8
Figure 4. Thermal derating curve, dependence per IEC/EN/DIN EN 60747-5-2.
Figure 6. Test circuit for transient immunity and typical waveforms. Figure 5. Switching test circuit.
0 V 10% 90% 90% 10%
www.agilent.com/semiconductors For product information and a complete list of distributors, please go to our web site. For technical assistance call: Americas/Canada: +1 (800) 235-0312 or (916) 788-6763 Europe: +49 (0) 6441 92460 China: 10800 650 0017 Hong Kong: (+65) 6756 2394 India, Australia, New Zealand: (+65) 6755 1939 Japan: (+81 3) 3335-8152 (Domestic/Interna- tional), or 0120-61-1280 (Domestic Only) Korea: (+65) 6755 1989 Singapore, Malaysia, Vietnam, Thailand, Philippines, Indonesia: (+65) 6755 2044 Taiwan: (+65) 6755 1843 Data subject to change. Copyright © 2004 Agilent Technologies, Inc. Obsoletes 5989-0300EN December 20, 2004 5989-2111EN