HCF4017B-HCF4022B ETC1 | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 12

Technical content

. FULLY STATIC OPERATION . MEDIUM SPEEDOPERATION-12MHz (typ.) AT VDD = 10V . STANDARDIZED SYMMETRICAL OUTPUT CHARACTERISTICS . QUIESCENT CURRENT SPECIFIED TO 20V FOR HCC DEVICE . INPUT CURRENT OF 100nA AT 18V AND 25°C FOR HCC DEVICE . 100% TESTED FOR QUIESCENT CURRENT . 5V, 10V, AND 15V PARAMETRIC RATINGS . MEETS ALLREQUIREMENTS OF JEDECTEN- TATIVE STANDARD N° 13A, ”STANDARD SPECIFICATIONS FOR DESCRIPTION OF ”B” SERIES CMOS DEVICES” June 1989 EY (Plastic Package) F (Ceramic Frit Seal Package) (Plastic Chip Carrier) ORDER CODES : HCC40XXBF HCF40XXBM1 HCF40XXBEY HCF40XXBC1 PIN CONNECTIONS 4017B DECADE COUNTER WITH 10 DECODED OUTPUTS 4022B OCTAL COUNTER WITH 8 DECODED OUTPUTS 4017B 4022B (Micro Package)

DESCRIPTION

(extended temperature range) and HCF4017B/4022B (intermediate tem- perature range) are monolithic integrated circuits, available in 16-lead dual in-line plastic or ceramic package and plastic micro package. The HCC/HCF4017B and HCC/HCF4022B are 5- stage and 4-stage Johnson counters having 10 and 8 decoded outputs, respectively. Inputs include a CLOCK, a RESET, and a CLOCK INHIBIT signal. Schmitt trigger action in the CLOCK input circuit pro- videspulse shaping that allows unlimited clockinput pulse rise and fall times. These counters are ad- vanced one count at the positive clock signal tran- sition if the CLOCK INHIBIT signal is low. Counter advancement via the clock line is inhibited when the CLOCKINHIBIT signalishigh. A high RESET signal clears the counter to its zero count. Use of the Johnson decade-counter configuration permits high-speed operation, 2-input decimal-decode gat- ing, and spike-free decoded outputs. Anti-lock gat- ing is provided, thus assuring proper counting sequence. The decoded outputs are normally low and go high only at their respective decoded time slot. Each decoded output remains high for one full clock cycle. A CARRY-OUT signal completes one

V DD* Supply Voltage : HCC Types HCF Types – 0.5 to + 20 – 0.5 to + 18 V V VI Input Voltage – 0.5 to VDD + 0.5 V II DC Input Current (any one input) ± 10 mA Pt ot Total Power Dissipation (per package) Dissipation per Output Transistor for Top = Full Package-temperature Range 200 100 mW mW T o p Operating Temperature : HCC Types HCF Types – 55 to + 125 – 40 to + 85 Tstg Storage Temperature – 65 to + 150 RECOMMENDED OPERATING CONDITIONS Symbol Parameter Value Unit VDD Supply Voltage : HCC Types HCF Types 3 to 18 3 to 15 V V VI Input Voltage 0 to VDD V T o p Operating Temperature : HCC Types HCF Types – 55 to + 125 – 40 to + 85 4022B Stresses above those listed under ”Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sec- tions of this specification is not implied. Exposure to absolute maximum rating conditions for external periods may affect device reliability. All voltages values are referred to VSS pin voltage. 4017B cycle every clock input cycles in the HCC/HCF4017B or every 8 clockinput cycles in the HCC/HCF4022B and isusedto ripple-clock the suc- ceeding device in a multi-device counting chain. HCC/HCF4017B/4022B

STATIC ELECTRICAL CHARACTERISTICS (over recommended operating conditions) Test Conditions Value VI VO | IO| VDD TLow* 25°C THigh* Symbol Parameter (V) (V) (µA) (V) Min. Max. Min. Typ. Max. Min. Max. Unit IL Quiescent Current HCC Types 0.04 150 µA 0.04 300 0.04 600 100 0.08 100 3000 HCF Types 0.04 150 0.04 300 0.04 600 VOH Output High Voltage < 1 4.95 4.95 4.95 V < 1 9.95 9.95 9.95 < 1 14.95 14.95 14.95 VOL Output Low Voltage < 1 0.05 0.05 0.05 V < 1 0.05 0.05 0.05 < 1 0.05 0.05 0.05 VIH Input High Voltage 0.5/4.5 < 1 3.5 3.5 3.5 V < 1 1.5/13.5 < 1 VIL Input Low Voltage 4.5/0.5 < 1 1.5 1.5 1.5 V < 1 13.5/1.5 < 1 IOH Output Drive Current HCC Types 2.5 – 2 – 1.6 – 3.2 1.15 mA 4.6 0.64 0.51 – 1 0.36 9.5 – 1.6 – 1.3 – 2.6 – 0.9 13.5 – 4.2 – 3.4 – 6.8 – 2.4 HCF Types 2.5 1.53 1.36 – 3.2 – 1.1 4.6 0.52 0.44 – 1 0.36 9.5 – 1.3 – 1.1 – 2.6 – 0.9 13.5 – 3.6 – 3.0 – 6.8 – 2.4 IOL Output Sink Current HCC Types 0.4 0.64 0.51 0.36 mA 0.5 1.6 1.3 2.6 0.9 1.5 4.2 3.4 6.8 2.4 HCF Types 0.4 0.52 0.44 0.36 0.5 1.3 1.1 2.6 0.9 1.5 3.6 3.0 6.8 2.4 IIH, IIL Input Leakage Current HCC Types Any Input ± 0.1 ±10–5 ± 0.1 ± 1 µA HCF Types ± 0.3 ±10–5 ± 0.3 ± 1 CI Input Capacitance Any Input 7.5 pF * TLow = – 55°C for HCC device : – 40°C for HCF device. * THigh = + 125°C for HCC device : + 85°C for HCF device. The Noise Margin for both ”1” and ”0” level is : 1V min. width VDD = 5V, 2V min. width VDD = 10V, 2.5V min. width VDD = 15V. HCC/HCF4017B/4022B

DYNAMIC ELECTRICAL CHARACTERISTICS (Tamb = 25°C, CL = 50pF, RL = 200kΩ, typical temperature coefficient for all VDD = 0.3%/°C values, all input rise and fall time = 20ns) Value Symbol Parameter Test Conditions VDD (V) Min. Typ. Max. Unit CLOCKED OPERATION tPLH, tPHL Propagation Delay Time Decode Out 325 650 ns 135 270 170 Carry Out 300 600 ns 125 250 160 tTHL, tTLH Transition Time Carry Out or Decoded Out Line 100 200 ns 100 fCL* Maximum Clock Input Frequency 2.5 MHz 5.5 tW Minimum Clock Pulse Width 100 200 ns tr, tf Clock Input Rise or Fall Time Unlimited µs tsetup Data Setup Time Minimum Clock Inhibit 115 230 ns 100 7.5 RESET OPERATION tPLH, tPHL Propagation Delay Time Carry Out or Decode Out Lines 265 530 ns 115 230 170 tW Minimum Reset Pulse Width 130 260 ns 110 trem Minimum Reset Removal Time 200 400 ns 140 280 150 * Measured with respect to carry output line. HCC/HCF4017B/4022B

Typical Output Low (sink) Current Characteristics. Minimum Output Low(sink) Current Characteristics. Typical Output High (source) Current Charac- teristics. Minimum Output High (source ) Current Charac- teristics. TYPICAL APPLICATIONS Divide by N Counter (N ≤10) with N Decoded Out- puts. When the Nth decoded output is reached (Nth clock pulse) the S-R flip-flop (constructed from two NOR gates of the HCC/HCF4001B) gener- ates a reset pulse which clears the HCC/HCF4017B to its zero count. At this time, if the Nth decoded output is greater than or equal to 6, the COUT line goes high to clock the next HCC/HCF4017B counter section. The ”0” decoded output also goes high at this time. Coin- cidence of the clock low and decoded ”0” output high resets the S-R flip flop to enable the HCC/HCF4017B. If the Nth decoded output is less than 6, the COUT line will not go high and, therefore, cannot be used. In this case ”0” decoded output may be used to perform the clocking function for the next counter. HCC/HCF4017B/4022B

Plastic DIP16 (0.25) MECHANICAL DATA DIM. mm inch MIN. TYP. MAX. MIN. TYP. MAX. 0.51 0.020 B 0.77 1.65 0.030 0.065 b 0.5 0.020 0.25 0.010 D 0.787 E 8.5 0.335 e 2.54 0.100 17.78 0.700 F 7.1 0.280 I 5.1 0.201 L 3.3 0.130 Z 1.27 0.050 P001C HCC/HCF4017B/4022B

Ceramic DIP16/1 MECHANICAL DATA DIM. mm inch MIN. TYP. MAX. MIN. TYP. MAX. A 0.787 B 0.276 D 3.3 0.130 E 0.38 0.015 17.78 0.700 F 2.29 2.79 0.090 0.110 G 0.4 0.55 0.016 0.022 H 1.17 1.52 0.046 0.060 L 0.22 0.31 0.009 0.012 M 0.51 1.27 0.020 0.050 N 10.3 0.406 P 7.8 8.05 0.307 0.317 Q 5.08 0.200 P053D HCC/HCF4017B/4022B

SO16 (Narrow) MECHANICAL DATA DIM. mm inch MIN. TYP. MAX. MIN. TYP. MAX. A 1.75 0.068 0.1 0.2 0.004 0.007 1.65 0.064 b 0.35 0.46 0.013 0.018 0.19 0.25 0.007 0.010 C 0.5 0.019 45° (typ.) D 9.8 0.385 0.393 E 5.8 6.2 0.228 0.244 e 1.27 0.050 8.89 0.350 F 3.8 4.0 0.149 0.157 G 4.6 5.3 0.181 0.208 L 0.5 1.27 0.019 0.050 M 0.62 0.024 S 8° (max.) P013H HCC/HCF4017B/4022B

DIM. mm inch MIN. TYP. MAX. MIN. TYP. MAX. A 9.78 10.03 0.385 0.395 B 8.89 9.04 0.350 0.356 D 4.2 4.57 0.165 0.180 2.54 0.100 0.56 0.022 E 7.37 8.38 0.290 0.330 e 1.27 0.050 5.08 0.200 F 0.38 0.015 G 0.101 0.004 M 1.27 0.050 1.14 0.045 P027A HCC/HCF4017B/4022B

Information furnished is believed to be accurate and reliable. However, SGS-THOMSON Microelectronics assumes no responsability for the consequences of use of such information nor for any infringement of patents or other rights of third parties which may results from its use. No license is granted by implication or otherwise under any patent or patent rights of SGS-THOMSON Microelectronics. Specificationsmentioned in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied. SGS-THOMSON Microelectronicsproductsare notauthorized foruse ascritical componentsin life support devices or systems without express written approval of SGS-THOMSON Microelectonics. 1994 SGS-THOMSON Microelectronics - All Rights Reserved SGS-THOMSON Microelectronics GROUP OF COMPANIES Australia - Brazil - France - Germany - Hong Kong - Italy - Japan - Korea - Malaysia - Malta - Morocco - The Netherlands - Singapore - Spain - Sweden - Switzerland - Taiwan - Thailand - United Kingdom - U.S.A HCC/HCF4017B/4022B