HC8-R39-R COOPER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Description
- Surface mount inductors, 4.0mm height, designed for higher speed switch mode applications requiring low voltage and high current
- 155°C maximum total operating temperature
- Design utilizes high temperature powder iron material with a non-organic binder to eliminate thermal aging
- Inductance offering expanded for applications requiring higher inductance.
- Inductance Range from 0.175 uH to 47.3 uH
- Current Range from 39.0 to 2.4 Amps
- Frequency Range 1kHz to 500kHz
Applications
- Next generation microprocessors
- High current DC-DC converters
- VRM, multi-phase buck regulator
- PC, Workstations, Routers
- Telecom soft switches, Base Stations Environmental Data
- Storage temperature range: -40°C to +155°C
- Operating ambient temperature range:-40° C to +155°C (range is application specific)
- Solder reflow temperature: +260°C max. for 10 seconds max. Packaging
- Supplied in tape and reel packaging, 800 parts per reel Part Rated OCL (1) Irms (2) Isat (3) Isat (4) DCR (m Ω) Volts (5) Number Inductance nominal Amperes Amperes Amperes max. @ µSec (VµS) µH +/-20% µH (Typ.) 15% rolloff 30% rolloff 20°C (ref.) 1) Test Parameters: 100KHz, 1.0Vrms 2) Irms Amperes for approximately ∆T of 40°C above 85°C ambient 3) Isat Amperes Peak for approximately 15% rolloff (@20°C) 4) Isat Amperes Peak for approximately 30% rolloff (@20°C) 5) Applied Volt-Time product (V-µS) across the inductor. This value represents the applied V-µS at operating frequency necessary to generate additional core loss which contributes to the 40°C temperature rise. De-rating of the Irms is required to prevent excessive temperature rise. The 100% V-uS rating is equivalent to a ripple current Ip-p of 20% of Isat (30% rolloff option). It is recommended that the temperature of the part not exceed 155°C under worst case operating conditions verified in the end application. Part number definition: HC8-XXX-R HC8 = Product code and size XXX = Inductance value in uH. R = Decimal point. If no R is present, third character = #of zeros -R suffix indicates RoHS compliant HC8 Series HIGH CURRENT 8 Power Inductors Mechanical Diagrams TOP VIEW 10.9 Max 10. 4 Max HC8-XXX wwllyy R 10.4 Max FRONT VIEW SIDE VIEW 2.70 ± 0.55 (2x) RECOMMENDED PCB PAD LAYOUT 4.0 typ 3.0 typ 2plcs 3.5 typ 2plcs 1 SCHEMATIC 4.0 Max C L A ref 3.95 2 plcs ref A mm 1R 2.1 1R9 thru 470 2.7 R39 R75 R15 PN 2.1 2.1 2.1 FRONT VIEW TABLE wwllyy = Date code R = Revision level xxx = Inductance value RoHS 2002/95/EC
2.0 Ao Ko=4.3 m m Ao=10.4 m m Bo=11.2 mm 1.5 dia +0.1/-0.0 Bo11.2 Ko SECTION A-A HC8-XXX wwllyy R 16.0 24.0 +/-0.3 11.5 4.0 1.5 dia min 1.75 User direction of feed A A Packaging Information Dimensions in Millimeters Irms DERATING WITH CORE LOSS 100 10 30 50 70 90 110 130 150 170 190 % Applied Volt-u Seconds % of Irms specified from zero ripple application 100kHz 200kHz 300kHz 400kHz 500kHz OCL vs Isat 100 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 % of Isat % of OCL Inductance Characteristics Core Loss Visit us on the Web at www.cooperbussmann.com 1225 Broken Sound Pkwy. Suite F Boca Raton, FL 33487 Tel: +1-561-998-4100 Toll Free: +1-888-414-2645 Fax: +1-561-241-6640 This bulletin is intended to present product design solutions and technical information that will help the end user with design applications. Cooper Electronic Technologies reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Electronic Technologies also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Life Support Policy: Cooper Electronic Technologies does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company . Life support systems are devices which support or sustain life, and whose failure to per form, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injur y to the user. PM-4120 3/07 © Cooper Electronic Technologies 2007