Features
Compliant to RoHS EU Directive 2002/95/EC (-Z versions) Compliant to ROHS EU Directive 2002/95/EC with lead solder exemption (non-Z versions) Delivers up to 10A Output current High efficiency – 90% at 3.3V full load Low Output voltage- supports migration to future IC supply voltages down to 1.0V Low output ripple and noise Small Size and low profile 47.2mm x 29.5mm x 8.5mm (1.86 x 1.16 x 0.335 in) Surface mount or Through hole (TH) Remote On/Off Output overcurrent/Over voltage protection Over temperature protection Single Tightly regulated output Output voltage adjustment trim ±10% Wide operating temperature range (-40°C to 85°C) Meets the voltage insulation requirements for ETSI 300-132-2 and complies with and is Licensed for Basic Insulation rating per EN 60950 CE mark meets 73/23/EEC and 93/68/EEC directives§ UL* 60950-1Recognized, CSA† C22.2 No. 60950-1-
03 Certified, and VDE‡ 0805:2001-12 (EN60950-1)
ISO** 9001 and ISO 14001 certified manufacturing facilities
Description
The HC series power modules are isolated dc-dc converters that operate over a wide input voltage range of 18 to 36 Vdc and provide one precisely regulated output. The output is fully isolated from the input, allowing versatile polarity configurations and grounding connections. The modules exhibit high efficiency, e.g. typical efficiency of 90% 3.3/10A, 91% at 5V/6A. Built-in filtering for both input and output minimizes the need for external filtering. These open frame modules are available either in surface-mount (-S) or in through-hole form. RoHS Compliant
May 16, 2008 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current LINEAGE POWER 2 Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage All V IN -0.3 50 Vdc Operating Ambient Temperature All T A -40 85 °C (see Thermal Considerations section) Storage Temperature All T stg -55 125 °C I/O Isolation Voltage (100% factory tested) All ⎯ ⎯ 1500 Vdc Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage HC V IN 18 24 36 Vdc Maximum Input Current HC I IN,max 3.2 Adc (VIN=0V to 75V, IO=IO, max) Inrush Transient All I t 1 A s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 12μH source impedance; VIN=0V to 75V, IO= IOmax ; see Figure 9) All 3 mAp-p Input Ripple Rejection (120Hz) All 50 dB EMC, EN55022 See EMC Considerations section CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 5A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.
May 16, 2008 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current LINEAGE POWER 3 Electrical Specifications (continued) Parameter Device Symbol Min Typ Max Unit Output Voltage Set-point 3.3V V O, set 3.25 3.3 3.35 Vdc (VIN=VIN,nom, IO=IO, max, Tref=25°C) 5.0V V O, set 4.92 5.0 5.08 Vdc Output Voltage All V O -3.0 ⎯ +3.0 % V O, set (Over all operating input voltage, resistive load, and temperature conditions until end of life) Adjustment Range All V O -10.0 +10.0 % V O, set Selected by external resistor Output Regulation Line (VIN=VIN, min to VIN, max) All ⎯ ⎯ 0.1 % V O, set Load (IO=IO, min to IO, max) All ⎯ ⎯ 10 mV Temperature (Tref=TA, min to TA, max) All ⎯ 0.2 ⎯ % VO, set Output Ripple and Noise on nominal output (VIN=VIN, nom and IO=IO, min to IO, max) Measured across 10μF tantalum//1μF ceramic RMS (5Hz to 20MHz bandwidth) All ⎯ 8 20 mV rms Peak-to-Peak (5Hz to 20MHz bandwidth) All ⎯ 40 75 mV pk-pk External Load Capacitance 3.3V C O, max 0 ⎯ 1000 μF 5.0V C O, max 0 ⎯ 470 μF Output Current 3.3V I o 0.05 10 Adc 5.0V I o 0.05 6.6 Adc (At Io < Io,min the output ripple may exceed the The max specifications. All modules shall Operate at no load without damage and without exceeding 100% of V O, set ) Output Current Limit Inception 3.3V I O, lim ⎯ 12 ⎯ Adc (Vo = 90% of VO, set) 5.0V I O, lim ⎯ 8 ⎯ Adc Output Short-Circuit Current 3.3V I O, s/c ⎯ 17 ⎯ Adc (VO≤250mV) 5.0V I O, s/c ⎯ 13 ⎯ Adc Efficiency 3.3V η ⎯ 90.0 ⎯ % VIN=VIN, nom, TA=25°C 5.0V η ⎯ 91.0 ⎯ % IO=IO, max , VO= VO,set
May 16, 2008 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current LINEAGE POWER 4 Electrical Specifications (continued) Parameter Device Symbol Min Typ Max Unit Switching Frequency All f sw ⎯ 285 ⎯ kHz Dynamic Load Response (ΔIo/Δt=0.1A/μs; Vin=Vin,nom; TA=25°C) Load Change from Io= 50% to 75% of Io,max Peak Deviation V pk ⎯ 200 ⎯ mV Settling Time (Vo<10% peak deviation) All t s ⎯ 200 ⎯ μs (ΔIo/Δt=0.1A/μs; Vin=Vin,nom; TA=25°C) Load Change from Io= 75% to 50% of Io,max Peak Deviation All V pk ⎯ 200 ⎯ mV Settling Time (Vo<10% peak deviation) All t s ⎯ 200 ⎯ μs Isolation Specifications Parameter Symbol Min Typ Max Unit Isolation Capacitance C iso ⎯ 1000 ⎯ pF Isolation Resistance R iso 10 ⎯ ⎯ MΩ General Specifications Parameter Min Typ Max Unit Calculated MTBF (for HC010A0F1 in accordance with Lucent RIN: IO=80% of IO, max, TA=25°C, airflow=1m/s) > TBD Hours Weight ⎯ 13 (0.46) Weight ⎯
May 16, 2008 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current LINEAGE POWER 5 Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter Device Symbol Min Typ Max Unit Remote On/Off Signal Interface (VIN=VIN, min to VIN, max ; open collector or equivalent, Signal referenced to VIN- terminal) Negative Logic: device code suffix “1” Logic Low = module On, Logic High = module Off Positive Logic: No device code suffix required Logic Low = module Off, Logic High = module On Logic Low Specification Remote On/Off Current – Logic Low All I on/off ⎯ 0.15 1.0 mA On/Off Voltage: Logic Low All V on/off -0.7 ⎯ 1.2 V Logic High – (Typ = Open Collector) All V on/off ⎯ 15 V Logic High maximum allowable leakage current All I on/off ⎯ ⎯ 50 μA Turn-On Delay and Rise Times (VIN=VIN, nom, IO=IO, max , VO to within ±1% of steady state) Case 1: On/Off input is set to Logic high and then input power is applied (delay from instant at which VI = VI,min until Vo = 10% of Vo, set) All Tdelay 20 msec Case 2: Input power is applied for at least one second and then the On/Off input is set to logic high (delay from instant at which Von/Off = 0.9V until Vo = 10% of Vo, set) All Tdelay 12 msec Output voltage Rise time (time for Vo to rise from 10% of Vo, set to 90% of Vo, set) All Trise ― 5 ― msec Output voltage overshoot (VIN=VIN, nom, Io = 80% of Io,max, TA=25°C) All ― ― 5 %VO, set Output Overvoltage Protection 3.3V V O, limit ⎯ 4.0 4.6 V 5.0V V O, limit ⎯ 6.1 7.0 V Overtemperature Protection All T ref ⎯ 125 ⎯ °C (See Feature Descriptions) Input Undervoltage Lockout Turn-on Threshold HC ⎯ 16 18 V Turn-off Threshold HC 13 14 ⎯ V
May 16, 2008 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current LINEAGE POWER 10 Feature Descriptions (continued) Output Voltage Programming (continued) Ω⎥⎦ ⎡ −Δ=− kBAdownRtrim % Rtrim-down is the external resistor in kΩ Δ% is the % change in output voltage Values of A & B are provided in Table 1 Table 1 Output Voltage (V) A B 3.3V 1690 73.1 5.0V 1690 73.1 Connecting an external resistor (Rtrim-up) between the TRIM pin and the VO(+) pin increases the output voltage set point. The relationship between the output voltage and the trim resistor value for a Δ% increase in output voltage is: Ω ⎧ −⎥⎦ Δ −Δ+=− kCBAupRtrim % %100( Rtrim-up is the external resistor in kΩ Δ% is the % change in output voltage Values of A , B and C are provided in Table 2 Table 2 Output Voltage (V) A B V 3.3 45.5 1690 73.1 5.0 69.0 1690 73.1 Examples: To trim down the output of a nominal 5.0V module (HC006A6A) to 4.90V Δ% = 2 Ω⎥⎦ ⎡ −=− kdownRtrim 1.732 1690 Ω=− kdownRtrim 9.771 To trim up the output of a nominal 3.3V module (HC010A0F) to 3.63V Δ% = 10 Ω ⎧ −⎥⎦ ⎡ −+=− kupRtrim 1.7310 1690)10100(5.45 Ω=− kupRtrim 4.258
May 16, 2008 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current LINEAGE POWER 12 Mechanical Outline for Surface-Mount Module Dimensions are in millimeters and (inches). Top View Side View Bottom View Pin Function
1 Vo(+)
2 Vo(-)
9 Trim
11 On/Off
17 Vin(-)
18 Vin(+)
29.5 (1.16) 47.2 (1.86) 0.06 x 0.06 chamffer 17 11 1 2 9 2.5 (0.10) min stand-off height 0.5 (.020) max compliance 8.50 (0.335) MAX VO+V O- TRIM 26.16 (1.030) 5.00 (0.197) VI+V I- 35.00 (1.375) On/Off 3.6 (0.14)1.7 (0.07) 40.00 (1.575)
May 16, 2008 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current LINEAGE POWER 13 Mechanical Outline for Through Hole Module Dimensions are in millimeters and [inches]. Top View Side View * Optional pin lengths shown in Table 2 Device Options Bottom View Pin Function
May 16, 2008 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current LINEAGE POWER 14 Recommended Pad Layout for Surface Mount and Through Hole Module Dimensions are in millimeters and [inches].
May 16, 2008 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current LINEAGE POWER 15 Packaging Details The surface mount versions of the HW005 family are also available in tape & reel (suffix –SR) as an option. Detailed of tape dimensions are shown below. Modules are shipped in quantities of 115 per reel. Tape Dimensions Dimensions are in millimeters and (inches). 40.00 (1.575) 4.00 (0.157) (1.346) 34.20 PICK POINT (2.692) 68.40 FEED DIRECTION (2.834) 72.00 9.02 (0.355) TOP COVER TAPE EMBOSSED CARRIER NOTE: CONFORMS TO EAI-481 REV. A STANDARD (2.692) 66.50 Reel Dimensions Outside diameter: 330.2 mm (13.00”) Inside diameter: 177.8 mm (7.00”) Tape Width: 72.00 mm (2.834”)
with both Pb and Pb-free wave soldering processes. representative for more details. Figure 21. Surface Mount Packaging Tray giving a total number of 45 power modules. label will withstand reflow temperatures up to 300°C. product code, date and location of manufacture.
May 16, 2008 HC006/010 Series DC-DC Power Module: 18-36Vdc Input; 3.3V & 5Vdc Output; 6.6A - 10A Output Current Document No: DS03-122 ver. 1.44 PDF name: hc006-010_series_ds.pdf
Ordering Information
Please contact your Lineage Power Sales Representative for pricing, availability and optional features. Table 1. Device Codes Table 2. Device Options
3000 Skyline Drive, Mesquite, TX 75149, USA
application. No rights under any patent accompany the sale of any such product(s) or information. © 2008 Lineage Power Corporation, (Mesquite, Texas) All International Rights Reserved.