HBU60 MPSIND | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

60W Open frame type medical power supplies for health care applications The HBU60 series of compact, open frame constructed, AC/DC switching mode power supplies provide 60 Watts of continuous output power .They are suited for use in health care applications. All models meet FCC Part-18 class B and CISPR-11 EN55011 class B emission limits and are designed to comply with UL/c-UL(UL nd nd60601-1:2 Edition) ,TUV/T-mark(EN 60601-1:2 Edition) and new CE requirements. All units are 100% burned in and tested. Electrical characteristics: Features: Description: Typ. Parameter Test Conditions Min. Max. Unit Safety Approvals Input Voltage Range 240 100 VAC Sym. Vin 0.72 1.62 Vin=90 to 264 VAC Io=Full load, Vin=115VAC Vin=230VAC W V A A A A A Output Power Range Efficiency Line Regulation Load Regulation 63 47 See rating Chart 26 30 43 47 Low Line Inrush Current Hz Iil Irh Eff REG-i REG-o Iih Irl fin Po Vo Io High Line Inrush Current Input Frequency Output Voltage Range Output Current Range Input Current (Low Line) Input Current (High Line) Io=Full load, Vin=230VAC Io=Full load, 25 C,Cool start, Vin=115VAC Io=Full load, 25 C,Cool start, Vin=230VAC Io=Full load See rating Chart Io=Full load, Vin=230VAC 1 0.3 2 -0.04 0.04 Time of Transient Response Hold-Up Time Safety Ground Leakage Current Temperature Coefficient S mA mS 0.30.1 OCP OVP Ttr Thold Ts Vp-p Ilk TC 150 132 110 112 Io=Full load, Vin=110VAC Over Current Protection Over Voltage Protection Io=Full load to Half Load, Vin=100VAC Start Up Time Io=Full load, Vin=100VAC Ripple & Noise (Peak to Peak) Full load, Vin=90VAC 1 % Io=Full load, Vin=240VAC mS12 16 %/ CAll output 264 90 VACOperate Voltage Range Wide Operating voltage 90 to 264 VAC,47 to 63 Hz Single output Input connector mates with molex housing 09-50-3031/35977-0300 and molex 2478/ 35922 series crimp terminal. Output connector mates with molex housing 09-50-3061/35977-0600 and molex 2478/ 35922 series crimp terminal. Input surge current, over voltage and over load protection Size: 2"x4”x1” Class I 2 year warranty Safety approvals : CBCB Environmental : Toper Operating Temperature Tstg Storage Temperature 0 70 -40 Sym. Parameter Min. Typ. Max. UnitTest Conditions C C Hr Ho Storage Humidity 75 % %Operating Humidity Pd 95 0 Derate linearly from 100% load at 40 C to 50% load at 70 C Hrs MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F 0.1M EN 60601-1 IEC 60601-1

Output voltage and current rating chart (Single output) : Mechanical specifications : Note: 1. Dimensions are shown in inches or mm. 2. Weight: 140gs approx. 3. Input connector mates with Molex housing 09-50-3031/35977-0300 and Molex 2478/ 35922 series crimp terminal. 4. Output connector mates with Molex housing 09-50-3061/35977-0600 and Molex 2478/ 35922 series crimp terminal. Safety specifications: Parameter Test Conditions Min. Typ. Max. Unit Dielectric Withstanding Voltage for Primary to secondary Primary to secondary 5656 VDC Sym. Vps Dielectric Withstanding Voltage for Primary to Ground Primary to ground 2828 VDCVpg Isolation Resistance Test Voltage=500VDC 50Ris Vin=220VAC B CLASSCISPR FCC EMI requirements for CISPR-11 Vin=110VAC B CLASSEMI requirements for FCC PART-18 M Pin Chart MODEL PIN HBU60-1XX 1 2 3 4 5 6 OUT RTN RTN RTNOUT OUT 60W Open frame type medical power supplies for health care applications Model Number Output Voltage Output Current Total Regulation Maximum Output Power HBU60-105 012 ~ 13 VDC 5.00 ~ 4.61 A 5% 60W HBU60-106 013 ~ 16 VDC 4.61 ~ 3.75 A 5% 60W HBU60-107 16 ~ 21 VDC 3.75 ~ 2.85 A 5% 60W HBU60-108 21 ~ 27 VDC 2.85 ~ 2.22 A 3% 60W HBU60-109 27 ~ 33 VDC 2.22 ~ 1.81 A 3% 60W HBU60-110 33 ~ 40 VDC 1.81 ~ 1.50 A 3% 60W