HBU31 MPSIND | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

30W Open Frame Type Medical Power Supplies For Health Care Applications The HBU31 series of compact, open frame constructed, AC/DC switching mode power supplies provide 30 Watts of continuous output power .They are suited for use in Health care applications. All models meet FCC Part-18 class B and CISPR-11 EN55011 class B emission Limits and are designed to comply with UL/c-UL(UL nd nd60601-1:2 Edition) ,TUV/T-mark(EN 60601-1:2 Edition) and new CE requirements. All units are 100% burned in and tested. Electrical Characteristics: Features: Description: Typ. Parameter Test Conditions Min. Max. Unit Safety Approvals Input Voltage Range 240 100 VAC Sym. Vin 0.3 0.4 0.8 0.5 1 Vin=90 to 264 VAC Io=Full load, Vin=115VAC Vin=230VAC W V A A A A A Output Power Range Efficiency Line Regulation Load Regulation 63 47 See rating Chart 15 18 25 40 Low Line Inrush Current Hz Iil Irh Eff REG-i REG-o Iih Irl fin Po Vo Io 8985 75 High Line Inrush Current Input Frequency Output Voltage Range Output Current Range Input Current (Low Line) Input Current (High Line) Io=Full load, Vin=230VAC Io=Full load, 25 C,Cool start, Vin=115VAC Io=Full load, 25 C,Cool start, Vin=230VAC Io=Full load See rating Chart Io=Full load, Vin=230VAC 0.25 0.5 -0.04 0.04 Time of Transient Response Hold-Up Time Safety Ground Leakage Current Temperature Coefficient S mA mS 0.30.1 0.5 OCP Ttr Thold Ts Vp-p Ilk TC 150 110 Io=Full load, Vin=110VAC Over Current Protection Io=Full load to Half Load, Vin=100VAC Start Up Time Io=Full load, Vin=100VAC Ripple & Noise (Peak to Peak) Full load, Vin=90VAC 1 % Io=Full load, Vin=240VAC mS12 18 %/ CAll output 264 90 VACOperate Voltage Range Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz Internal EMI filter Single Output Input connector mates with Molex housing 09-50-3031 and Molex 2478 series crimp terminal Output connector mates with Molex housing 09-50-3041 and Molex 2478 series crimp terminal Input Surge Current, Over Voltage and Over Load protection Size: 1.5"x4”x0.83” Class II 2 year warranty Safety Approvals : CBCB Environmental : Toper Operating Temperature Tstg Storage Temperature 0 70 -40 Sym. Parameter Min. Typ. Max. UnitTest Conditions C C Hr Ho Storage Humidity 75 % %Operating Humidity Pd 95 0 Derate linearly from 100% load at 40 C to 50% load at 70 C Hrs MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F 0.1M EN 60601-1 IEC 60601-1

Safety Specifications: Parameter Test Conditions Min. Typ. Max. Unit Dielectric Withstanding Voltage for Primary to secondary Primary to secondary 5656 VDC Sym. Vps Vin=220VAC B CLASSCISPR FCC EMI requirements for CISPR-11 Vin=110VAC B CLASSEMI requirements for FCC PART-18 Output Voltage And Current Rating Chart (Single Output) : Mechanical Specifications : Note: 1. Dimensions are shown in inches or mm. 2. Weight: 85gs approx. 3. Input connector mates with Molex housing 09-50-3031 and Molex 2478 series crimp terminal. 4. Output connector mates with Molex housing 09-50-3041 and Molex 2478 series crimp terminal. HBU31 SERIES 30W Open Frame Type Medical Power Supplies For Health Care Applications N L 1 Model Number Output Voltage Output Current Total Regulation Maximum Output Power HBU31-102 05 ~ 06 VDC 4.00 ~ 3.33 A 5% 20W HBU31-103 06 ~ 08 VDC 3.83 ~ 2.87 A 5% 23W HBU31-104 8 ~ 11 VDC 3.37 ~ 2.45 A 5% 27W HBU31-105 11 ~ 13 VDC 2.72 ~ 2.31 A 5% 30W HBU31-106 13 ~ 16 VDC 2.31 ~ 1.88 A 5% 30W HBU31-107 16 ~ 21 VDC 1.88 ~ 1.43 A 5% 30W HBU31-108 21 ~ 27 VDC 1.43 ~ 1.12 A 3% 30W HBU31-109 27 ~ 33 VDC 1.12 ~ 0.91 A 3% 30W HBU31-110 33 ~ 40 VDC 0.91 ~ 0.76 A 3% 30W