Rev:20120814A Page 1 of 7 Isolated DC-DC Converters HBA1 Series -- 1Watt Fea tures /circle6 7 pin SIP package /circle6 In put / Output Isolation Voltage: 6.4kVDC /circle6 High Efficiency /circle6 Lead Free Design, RoHS Compliant /circle6 Operating temperature: -40° C to +85° C /circle6 Optional Reinforced Isolation 8kVDC /circle6 Safety Standard / Approval: IEC / EN 60950-1 EC / EN 60601-1 Tec hnical Specification All specifications are typical at nominal input, full load and 25° C unless otherwise stated. Output Current (mA) Input Current (mA) Model Number Reinforced Isolation 8kVDC Input Voltage Range(V) Output Voltage (V) Full Load No Load Full Load Eff .(2 ) (%) Capacitive Load, max.(3 ) (uF) HBA1-05S0H6 HBA1-05S0H8 3.3 303 27 8 76 3300 HBA1-05S1H6 HBA1-05S1H8 5 200 27 1 78 2200 HBA1-05SBH6 HBA1-05SBH8 7.2 140 27 3 78 1000 HBA1-05SAH6 HBA1-05SAH8 9 111 26 3 80 1000 HBA1-05S2H6 HBA1-05S2H8 12 84 26 2 81 470 HBA1-05S3H6 HBA1-05S3H8 15 66 25 3 82 470 HBA1-05D0H6 HBA1-05D0H8 ±3.3 ±151 28 1 75 ±2200 HBA1-05D1H6 HBA1-05D1H8 ±5 ±100 27 1 78 ±1000 HBA1-05DBH6 HBA1-05DBH8 ±7.2 ±70 27 3 78 ±470 HBA1-05DAH6 HBA1-05DAH8 ±9 ±55 26 4 79 ±470 HBA1-05D2H6 HBA1-05D2H8 ±12 ±41 25 9 80 ±220 HBA1-05D3H6 HBA1-05D3H8 4.5 ~ 5.5 No minal: 5 ±15 ±33 258 81 ±220 HBA1-12S0H6 HBA1-12S0H8 3.3 303 11 6 76 3300 HBA1-12S1H6 HBA1-12S1H8 5 200 11 3 78 2200 HBA1-12SBH6 HBA1-12SBH8 7.2 140 11 4 78 1000 HBA1-12SAH6 HBA1-12SAH8 9 111 11 0 80 1000 HBA1-12S2H6 HBA1-12S2H8 12 84 11 0 81 470 HBA1-12S3H6 HBA1-12S3H8 15 66 10 6 82 470 HBA1-12D0H6 HBA1-12D0H8 ±3.3 ±151 11 7 75 ±2200 HBA1-12D1H6 HBA1-12D1H8 ±5 ±100 11 3 78 ±1000 HBA1-12DBH6 HBA1-12DBH8 ±7.2 ±70 11 4 78 ±470 HBA1-12DAH6 HBA1-12DAH8 ±9 ±55 11 0 79 ±470 HBA1-12D2H6 HBA1-12D2H8 ±12 ±41 10 8 80 ±220 HBA1-12D3H6 HBA1-12D3H8 10.8 ~ 13.2 No minal: 12 ±15 ±33 108 81 ±220

Applications

These converters are well suitable for battery operated equipment, measurement equipment, telecom, wireless network, Industry control system, everywhere where isolated, tightly regulated voltages and compact size are required. Bothhand USA sales@bothhandusa.com www.bothhandusa.com

Rev:20120814A Page 2 of 7 Isolated DC-DC Converters HBA1 Series -- 1Watt Output Current (mA) Input Current (mA) Model Number Reinforced Isolation 8kVDC Input Voltage Range(V) Output Voltage (V) Full Load No Load Full Load Eff .(2 ) (%) Capacitive Load, max.(3 ) (uF) HBA1-15S0H6 HBA1-15S0H8 3.3 303 93 76 3300 HBA1-15S1H6 HBA1-15S1H8 5 200 91 78 2200 HBA1-15SBH6 HBA1-15SBH8 7.2 140 91 78 1000 HBA1-15SAH6 HBA1-15SAH8 9 111 88 80 1000 HBA1-15S2H6 HBA1-15S2H8 12 84 88 81 470 HBA1-15S3H6 HBA1-15S3H8 15 66 85 82 470 HBA1-15D0H6 HBA1-15D0H8 ±3.3 ±151 94 75 ±2200 HBA1-15D1H6 HBA1-15D1H8 ±5 ±100 91 78 ±1000 HBA1-15DBH6 HBA1-15DBH8 ±7.2 ±70 91 78 ±470 HBA1-15DAH6 HBA1-15DAH8 ±9 ±55 88 79 ±470 HBA1-15D2H6 HBA1-15D2H8 ±12 ±41 87 80 ±220 HBA1-15D3H6 HBA1-15D3H8 13.5 ~ 16.5 No minal: 15 ±15 ±33 86 81 ±220 HBA1-24S0H6 HBA1-24S0H8 3.3 303 58 76 3300 HBA1-24S1H6 HBA1-24S1H8 5 200 57 78 2200 HBA1-24SBH6 HBA1-24SBH8 7.2 140 57 78 1000 HBA1-24SAH6 HBA1-24SAH8 9 111 54 80 1000 HBA1-24S2H6 HBA1-24S2H8 12 84 55 81 470 HBA1-24S3H6 HBA1-24S3H8 15 66 53 82 470 HBA1-24D0H6 HBA1-24D0H8 ±3.3 ±151 59 75 ±2200 HBA1-24D1H6 HBA1-24D1H8 ±5 ±100 57 78 ±1000 HBA1-24DBH6 HBA1-24DBH8 ±7.2 ±70 57 78 ±470 HBA1-24DAH6 HBA1-24DAH8 ±9 ±55 55 79 ±470 HBA1-24D2H6 HBA1-24D2H8 ±12 ±41 54 80 ±220 HBA1-24D3H6 HBA1-24D3H8 21.6 ~ 26.4 No minal: 24 ±15 ±33 54 81 ±220 Input Specifications 5V nominal input 4.5~5.5V 12V nominal input 10 .8~13.2V 15V nominal input 13 .5~16.5V Input voltage V nominal input 21.6~26.4V Input filter Capacitor Environmental Specifications Operating ambient temperature -4 0° C to +85° C Maximum case temperature +9 5° C Storage temperature range -5 5° C to +125° C Relative humidity 95 % RH max. Output Specifications Output power 1 Watts max. Voltage accuracy Nominal Vin and full load ±5% max. Bothhand USA sales@bothhandusa.com www.bothhandusa.com

Rev:20120814A Page 3 of 7 Isolated DC-DC Converters HBA1 Series -- 1Watt Vo ltage balance Dual output ±1% max. Minimum load 0A Line regulation Fo r Vin charge of 1% ±1.5% max. 10% max. Load Regulation 10 % load to full load 15% max. (3.3&5Vout models) Ripple and Noise (20MHz Bandwidth) 15 0mVp-p max. Maximum capacitive load Se e table Output short circuit protection 1 second General Specifications Efficiency No minal input and full load See table Isolation voltage In put to output 6400VDC (1 second) Isolation resistance 50 0VDC 15GΩ min. Isolation capacitance 10 pF max. Switching frequency 80 kHz max. Reliability, calculated MTBF 2×10 6 Hrs Physical Specifications Case material Plastic (UL94 V-0) Potting material Ep oxy (UL94 V-0) 0. 77 × 0.50 × 0.39 Inch Dimensions Weight 4.3g (0.15oz) typ. Note Io below this value will not damage these converters, however, they may not meet all listed specifications. 2. Typical value, tested at nominal input and full load. 3. For each output. Bothhand USA sales@bothhandusa.com www.bothhandusa.com

Rev:20120814A Page 4 of 7 Isolated DC-DC Converters HBA1 Series -- 1Watt Mechanical Dimensions Single output Dual output Spe cifications subject to change without notice. Pin Assignment Pin Single Dual 1 +Vin +Vin 2 -Vin -Vin 5 -Vout -Vout

6 No pin Common

Unit: mm (inch) To lerance: XX.XX ±0.25 (±0.01) Date Code 9.80 .39) 5.00 .20) 8.50 .33) Printed Fa ceHBAX-XXDXHX Pb 19.50 .77) 16.50 .65) 12.50 .50) 10.40 .41) 7.62 .30) 2.54 .10) 15.24 .60) 4.10 .162) 0.50 .02) 0.50 .02) 0.25 .01) 2.36 .093) 1.90 .075) 2.40 .094) HBAX-XXSXHX Pb 19.50 .77) 16.50 .65) 12.50 .50) 10.40 .41) 7.62 .30) 2.54 .10) 15.24 .60) 4.10 .162) Date Code 0.50 .02) 0.50 .02) 9.80 .39) 5.00 .20) 8.50 .33) Printed Fac e 0.25 .01) 2.36 .093) 1.90 .075) 2.40 .094) Bothhand USA sales@bothhandusa.com www.bothhandusa.com

Rev:20120814A Page 5 of 7 Isolated DC-DC Converters HBA1 Series -- 1Watt Test Configurations All specifications are typical at nominal input, full load and 25° C unless otherwise stated. ◎DC Power Supply: It offers a wide voltage and current range precisely. ◎Current meter (A): Accuracy/barb4right 200μA ~ 200mA 4 ranges+ (0.2% rdg + 2 digits) 200 0mA ~ 20A 2 ranges+ (0.3% rdg + 2 digits). ◎Vol tage meter (V): Accuracy/barb4right +(0.03% rdg + 4 digits). ◎Loa d: At full load. ◎Wires: The resistance of the wires must be small. 1. Input voltage range: Narrow input voltage range(±1 0%) 、wide input voltage range (2:1 and 4:1) 。 EX: Narrow input voltage range (±10%) 5V nominal input /barb4right 4.5~5.5V 12V nominal input /barb4right 10.8~13.2V 24V nominal input /barb4right 21.6~26.4V Wide input voltage range 2:1 5V nominal input /barb4right 4.5~9V 12V nominal input /barb4right 9~18V 24V nominal input /barb4right 18~36V 48V nominal input /barb4right 36~75V Wide input voltage range 4:1 (W) 24V nominal input /barb4right 9~36V 48V nominal input /barb4right 18~75V 2. Input power : Pin = Vin x Iin Vin :Inpu t voltage Iin :Input current 3. Output power : Pout = Vout x Iout Vout :Outp ut voltage Iout :Output current 4. Efficiency : Pout: Output power Pin: Input power 5. Voltage accuracy: Vou t:Output voltage Vou t(nominal):Nominal output voltage DC Power Supply A V LoadDC/DC converter V A DC Power Supply A V LoadDC/DC converter V A Vout x100% Efficiency = x10 0% Pout Pin Bothhand USA sales@bothhandusa.com www.bothhandusa.com

Rev:20120814A Page 6 of 7 Isolated DC-DC Converters HBA1 Series -- 1Watt Noise Ripple Ripple&Noise . Line regulation: (1) Wide input voltage range and regulated output vol tage series. (2) Narrow input voltage range(±10 %)and unregulated output voltage series. ΔΔ ΔΔVout = Vout(+10%)-Vout(-10%) x100% Vo ut Vout(+10%):Output voltage at Vin = 1.1xVin(nominal)&full load Vout(-10%):Output voltage at Vin = 0.9xVin(nominal)&full load Vout:Output voltage at Vin = Vin(nominal)&full load ΔΔ ΔΔVin = Vin(+10%)-Vin(-10%) x100% Vi n(nominal) Vin(+10%):Input voltage = 1.1xVin(nominal) Vin(-10%):Input voltage = 0.9xVin(nominal) Vin(nominal):Nominal Input voltage 7. Load regulation : Vo ut(FL) Vout(FL): Output voltage at full load Vout(NL): Output voltage at 25% full load or 10% full load 8. Ripple and Noise: as shown below. The bandwidth is 0-20MHz. Vout(LL) LL : Low Line input voltage HL: High Line input voltage x100% ΔΔΔΔV out ΔΔΔΔV in Line regulation= Bothhand USA sales@bothhandusa.com www.bothhandusa.com

Rev:20120814A Page 7 of 7 Isolated DC-DC Converters HBA1 Series -- 1Watt Ou tput Ripple&Noise measurement test circuit: as shown below. Co: usually 0.47uF. 9. Temperature derating curve : The DC-DC converter will operate over a wider temperat ure range if less power is drawn from the output and the device is already running. The temperature derating curve shows the operating power-temperature range. As shown below. Ambient Temp.TA (℃℃ ℃℃) 0. Switching frequency: The nominal operating frequency of the DC-DC converter s. 11. I nput to output isolation: The dielectric breakdown strength test between input a nd output circuits. This is the isolation voltage the device is capable of withstanding for a specified time, usually 1 second or 1 minute. LoadDC/DC converter Oscilloscope Copper strip Copper strip Co LoadDC/DC converter Oscilloscope Copper strip Copper strip LoadDC/DC converter Oscilloscope Copper strip Copper strip Co Output Power (%) Bothhand USA sales@bothhandusa.com www.bothhandusa.com