HB84G NORGREN | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 8
Technical content
+80°C (+176°F) -40°C (-40°F) Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021 - 9348a) © 2020 Norgren Ltd en/en 8.200.350.01 Technical features filter/regulator HB84G - Filter/regulator For Extreme Temperature applications Excelon® Plus Modular System > Port size: 3/8” ... 3/4” (ISO G/PTF) > Excelon® Plus design allows in-line installation or modular installation with other Excelon® Plus products > 5 or 40 micron particle and high efficiency water removal (> 98%) > Easy filter maintenance system. Element is removed together with the bowl for faster and cleaner servicing > Double safety lock bowl > Salt Spray compliant to ISO 9227 > Air purity classes in accordance to ISO8573-1:2010: 7:8:4 (40μm) 6:8:4 (5μm) > ABS cover with High impact properties Medium: Compressed air only Maximum supply pressure: 20 bar (290 psi) Outlet pressure ranges: Filter element: 5 μm & 40 μm Port size: G3/8, G1/2, G3/4, 3/8 PTF, 1/2 PTF, 3/4 PTF Gauge: Gauge port as standard ( Rc 1/8 or 1/8 PTF) Integrated gauge as option Flow: 103 dm³/s at port size: ½” , Inlet pressure 10 bar (145 psi), 6.3 bar (91 psi) set pressure and a Δp: 1 bar (14.5 psi) drop from set. Filter element: 5µm & 40µm Diaphragm Type: Relieving & Non-Relieving Drain: Manual or automatic Automatic drain operating conditions (float operated): Bowl pressure required to close drain: > 0.35 bar (5 psi) Bowl pressure required to open drain: ≤ 0.2 bar (2.9 psi) Minimum air flow required to close drain: 1 dm3/s (2 scfm) Ambient/Media temperature: Unit with gauge port without integrated gauge : Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Atex: Filter/regulators HB84 are in conformity with Atex 2014/34/EU II 2 GD Ex h IIC T6 Gb EX h IIIC T85°C Db Materials: Body: Die cast aluminium Body covers: ABS (Magnum 3904) Bonnet: Die cast aluminium Valve: Brass and Low temperature Nitrile Metal Bowl: Die cast Aluminium Filter element: sintered Poly- propylene Diaphragm: Low temperature Silicone, polyester reinforced Lower spring rest and diaphragm retainer: Aluminium Bowl O-ring: Low temperature Nitrile Elastomers: Low temperature Nitrile
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021 - 9348a) © 2020 Norgren Ltden/en 8.200.350.02 Option selector *1) Port size Substitute 3/8” 3 1/2” 4 3/4” 6 Thread form Substitute PTF A ISO G G Drain Substitute Manual (standard) M Auto drain (standard) A Open ended ( with male thread adaptor) N*2) *1) All models shown here are applicable for flow direction left to right. With flow direction right to left please use the online configurator www.norgren.com/air-preparation-configurator or contact Norgren *2) Available on request Gauge Substitute Without integrated gauge but with gauge port 1/8” N With integrated gauge *4) G Pressure range *3) Substitute 0.3 ... 4 bar F 0.3 ... 10 bar M 0.7 ...17 bar S Diaphragm Type Substitute Relieving R Non-Relieving N Element Substitute 5 µm 1 40 µm 3 Bowl Substitute Metal with liquid indicator D Metal M *3) Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges. *4) Attention : With integrated gauge temperature range of the unit changes to -20°C ... +65°C Technical data HB84G - standard models with gauge port Rc1/8 (without gauge) Symbol Port size Drain Pressure range Filter element Bowl Weight Model *1) (bar) (µm) (kg) *1) All models shown here are applicable for flow direction left to right. With flow direction right to left please use the online configurator www.norgren.com/air-preparation-configurator or contact Norgren
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10 20 30 40 50 60 70 80 90 100 Outlet pressure (bar) Air flow (dm3/s) TRE - B84G - 1/2" port - 10 bar spring - 10 bar inlet- 40 micron filter TRE - B84G - 3/8" port - 10 bar spring - 10 bar inlet - 40 micron filter 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 0 10 20 30 40 50 60 70 80 90 100 Outlet pressure (bar) Air flow (dm3/s) 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10 20 30 40 50 60 70 80 90 100 Outlet pressure (bar) Air flow (dm3/s) TRE - B84G - 1/2" port - 10 bar spring - 10 bar inlet- 40 micron filter TRE - B84G - 3/8" port - 10 bar spring - 10 bar inlet - 40 micron filter 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 0 10 20 30 40 50 60 70 80 90 100 Outlet pressure (bar) Air flow (dm3/s) Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021 - 9348a) © 2020 Norgren Ltd en/en 8.200.350.03 Flow characteristics Inlet pressure: 10 bar (145 psi) Port size: 1/2” , 40 µm element Inlet pressure: 10 bar (145 psi) Port size: 3/8” , 40 µm element Outlet pressure (bar) Air flow (dm3/s) Outlet pressure (bar) Air flow (dm3/s)
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021 - 9348a) © 2020 Norgren Ltden/en 8.200.350.04 Accessories Quikclamp® Page 6 H840014-51KIT Quikclamp® with bracket assembled Page 6 H840014-52KIT Neck mounting bracket and panel nut Page 6 840068-51KIT Panel mounting nut Page 6 840048-89KIT Mounting bracket Page 6 840024-50KIT Gauge adaptor kit 1/8 PTF H840143-01KIT Gauge adaptor kit R 1/8 H840143-02KIT Pressure sensing block 1/4 PTF Page 7 H840016-50KIT Pressure sensing block G1/4 Page 7 H840016-51KIT Full flow porting block vertical, 3/4”PTF Page 7 H840028-68KIT Full flow porting block vertical, G3/4” Page 7 H840028-69KIT Full flow porting block horizontal, 3/4 PTF Page 7 H840028-50KIT Full flow porting block horizontal, G3/4 Page 7 H840028-53KIT Port Adaptors Page 8 3/8 PTF H840015-02KIT 1/2 PTF H840015-03KIT 3/4 PTF H840015-04KIT G3/8 H840015-10KIT G1/2 H840015-11KIT G3/4 H840015-12KIT Maintenance/Service Filter cartridge 5 micron H840038-50KIT Filter cartridge 40 micron H840038-51KIT Auto drain kit with metal Nut 3000-40 Pressure switch interface block (18D pressure switch) G1/4 Page 6 0337717000000000 Pressure switch 18D (0,5 ... 8bar) *4 Page 8 0881300 Digital pressure switch Page 8 0860810 HR84 / HB84 Elastomer Kit, relieving HFRLB84-KIT HR84 / HB84 Elastomer kit, Non-relieving FRLB84NR-KIT
#25 143 163 #25 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021 - 9348a) © 2020 Norgren Ltd en/en 8.200.350.05 Dimensions Dimensions in mm Projection/First angle # Minimum clearance for bowl removal
1 Main ports 3/8” , 1/2” or 3/4”
(ISO G/PTF)
2 Gauge port Rc 1/8 for ISO G and
1/8 PTF for PTF main ports
3 Port size automatic drain : G1/8
54.3 56 11.5 50.1 6.1 23.0 7.20 30.0 36.0 70.3 25.0 Ø54.3 36.55.5 15 15 12 30.5 31 15 27.2 55.25 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021 - 9348a) © 2020 Norgren Ltden/en 8.200.350.06 Dimensions in mm Projection/First angle Accessories Quikclamp® with wall bracket Quikclamp® Neck mounting bracketPanel mounting nut Recommended panel hole size: ø 55 mm ... 57 mm Panel thickness: 2 ... 6 mm Mounting bracket
38.5 38.5 80 51 5746 G1/2
18 A/C
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021 - 9348a) © 2020 Norgren Ltd en/en 8.200.350.07 Dimensions in mm Projection/First angle Pressure sensing block Pipe adaptor Full flow porting block horizontal Full flow porting block vertical Porting block for 18D pressure switch 18D Pressure switch18D Porting block and 18D assembled
~300 31 G1/8 36,5 ~30 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2021 - 9348a) © 2020 Norgren Ltden/en 8.200.350.08 Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering, Norgren Ltd. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. EN - Englisch Dimensions in mm Projection/First angle 51D Pressure switch - digital