DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 22

Technical content

Solid-state Timer H3BA-N 1 Solid-state Timer H3BA-N Solid-state Timer with Valuable Multiple-time Ranges and Multiple-operating Modes

  • Handles a wide range of applications through eight operating modes.  With H3BA-N8H models, the output type can be switched between time-limit DPDT and time-limit SPDT + instantaneous SPDT using a selector.  Setting rings (order separately) to enable consistent settings and to limit the setting range.  Panel Covers (order separately) to enable various panel designs.  CE marking. UL, CSA and CCC certification, conforms to LR. ■Broad Line-up of H3B@-N Series H3B@-N Multi-functional Timer H3BA-N H3BA-N8H Twin Timer Star-delta Timer H3BG-N8 H3BG-N8H Power OFF-delay Timer H3BH-N8 H3BH-NH3BG-NH3BF-NH3BA-N Note: Refer to the H3BF-N/BG-N/BH-N Datasheet (Cat. No. L094-E1-02) for details. 11-pin model 8-pin with instantaneous contact output and time-limit output 8-pin with instantaneous contact output H3BF-N8 8-pin model 8-pin model8-pin model Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and Application Considerations (page 21), and Safety Precautions (page 17).

2 Solid-state Timer H3BA-N

■Model Number Legend 1. Number of Pins/Output None: 11-pin models/Time-limit DPDT 8H: 8-pin models/Time-limit SPDT and switchable SPDT (time-limit ↔ instantaneous)

Ordering Information

■List of Models ■Accessories (Order Separately) Note: 1. The Time Setting Ring and Panel Cover are sold together. 2. Hold-down Clips are sold in sets of two. H3BA-N@ Control output Supply voltage 11-pin models 8-pin models Contact output: DPDT (time-limit output) 110 VAC (50/60 Hz) H3BA-N 110 VAC ---

220 VAC (50/60 Hz) H3BA-N 220 VAC

24 VDC H3BA-N 24 VDC

Contact output: Time-limit SPDT and switchable SPDT (time-limit ↔ instantaneous)

110 VAC (50/60 Hz) --- H3BA-N8H 110 VAC

220 VAC (50/60 Hz) H3BA-N8H 220 VAC

24 VDC H3BA-N8H 24 VDC

Name/specifications Models Flush Mounting Adapters Y92F-30 Y92F-70 Y92F-71 Mounting Tracks 50 cm (l) × 7.3 mm (t) PFP-50N 1 m (l) × 7.3 mm (t) PFP-100N 1 m (l) × 16 mm (t) PFP-100N2 End Plate PFP-M Spacer PFP-S Protective Cover Y92A-48B Track Mounting/ Front Connecting Sockets 8-pin P2CF-08 11-pin P2CF-11 Back Connecting Sockets 8-pin P3G-08 11-pin P3GA-11 Time Setting Rings Setting a specific time Y92S-27 Limiting the setting range Y92S-28 Panel Covers (See note 1.) Light gray (5Y7/1) Y92P-48GL Black (N1.5) Y92P-48GB Hold-down Clips (See note 2.) For PL08 Socket Y92H-1 For PF085A Socket Y92H-2

Solid-state Timer H3BA-N 3 Specifications ■General * CCC certification requirements ■Time Ranges Item H3BA-N H3BA-N8H Operating mode A: ON-delay B: Flicker OFF start B2: Flicker ON start C: Signal ON/OFF-delay D: Signal OFF-delay E: Interval G: Signal ON/OFF-delay J: One-shot A: ON-delay H: ON-delay with instantaneous output contact Pin type 11-pin 8-pin Input type No-voltage input --- Output type DPDT (time-limit) SPDT (time-limit) and switchable SPDT (time-limit <---> instantaneous) Mounting method DIN track mounting, surface mounting, and flush mounting Approved standards UL508, CSA C22.2 No.14, LR, CCC : GB/T 14048.5 * Conforms to EN61812-1 (Pollution degree 2 / Overvoltage category ΙΙΙ) EMC (EMI) EN61812-1 Radiated Emissions: EN 55011 class A Emission AC Mains: EN 55011 class A (EMS) EN61812-1 ESD Immunity: EN 61000-4-2: 6 kV contact discharge, 8 kV air discharge Radiated Radio-Frequency EN 61000-4-3: 10 V/m (80 MHz to 1 GHz AM modulation) Electromagnetic Field Immunity: 3 V/m (1.4 GHz to 2 GHz AM modulation) 1 V/m (2 GHz to 2.7 GHz AM modulation)

10 V/m (900 MHz Pulse modulation)

Conducted disturbances: EN 61000-4-6: 10 V (0.15 MHz to 80 MHz) Burst Immunity: EN 61000-4-4: 2 kV power line 2 kV I/O signal line Surge Immunity: EN 61000-4-5: 2 kV common mode 1 kV differential mode Voltage dips: EN 61000-4-11 Voltage interruptions: EN 61000-4-11 Recommended fuse 0216005 (250 VAC, 5 A) manufactured by Littelfuse Rated operating voltage Ue Rated operating current Ie AC-15: Ue: 250 VAC, Ie: 3 A AC-13: Ue: 250 VAC, Ie: 5 A DC-13: Ue: 30 VDC, Ie: 1.5 A Rated insulation voltage 250 V Rated impulse withstand voltage (altitude: 2,000 m max.) 4 kV (at 240 VAC) Conditional short-circuit current 1,000 A Time unit sec × 10 s min × 10 m hrs × 10 hFull scale setting 3 0.3 to 3 3 to 30 0.3 to 3 3 to 30 0.3 to 3 3 to 30 12 1.2 to 12 12 to 120 1.2 to 12 12 to 120 1.2 to 12 12 to 120 30 3 to 30 30 to 300 3 to 30 30 to 300 3 to 30 30 to 300

4 Solid-state Timer H3BA-N

■Ratings Note: 1. DC ripple rate: 20% max. 2. Models other than 24-VDC H3BA-N models cause an inrush current. Pay careful attention when attempting to turn on power to such models with non-contact output from a device such as a sensor. 3. 90% or higher if the Timer is used continuously at a high ambient temperature. ■Characteristics Note: For setting the time-limit of the Timer to a cycle of less than 3 seconds or applying the forced reset, use the H3BA-N in mode D (signal OFF- delay). Item H3BA-N H3BA-N8H Rated supply voltage (See notes 1 and 2)

110 VAC (50/60 Hz), 220 VAC (50/60 Hz), 24 VDC

(See note 3) 85% to 110% of rated supply voltage Power reset Minimum power-opening time: 0.1 s No-voltage input ON impedance: 1 k Ω max. ON residual voltage: 1 V max. OFF impedance: 200 k Ω min. Power consumption 110 VAC: Approx. 4.6 VA (1.5 W) 220 VAC: Approx. 7.6 VA (1.3 W) 24 VDC: Approx. 0.6 W 110 VAC: Approx. 3.6 VA (1.6 W) 220 VAC: Approx. 7.8 VA (1.9 W) 24 VDC: Approx. 0.9 W Control outputs Contact: 5 A at 250 VAC, resistance load (cosφ = 1) Item H3BA-N H3BA-N8H Accuracy of operating time ±0.3% FS max. (±0.3%±10 ms in a range of 1.2 s) Setting error ±5% FS ±0.05 s max. Reset time Min. power-opening time: 0.1 s max. Min. pulse-input time: 50 ms Influence of voltage ±0.5% FS max. (±0.5%±10 ms in a range of 1.2 s) Influence of temperature ±2% FS max. (±2%±10 ms in a range of 1.2 s) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal parts 2,000 VAC, 50/60 Hz for 1 min between control output terminals and operating circuit 1,000 VAC, 50/60 Hz for 1 min between contacts not located next to each other (750 VAC for H3BA-N8H) Impulse withstand voltage 1 kV (between power terminals) 2 kV (between current-carrying terminal and exposed non-current-carrying metal parts, 1.5 kV for 24-VDC models) Noise immunity AC models: ±1.5 kV (between power terminals), and ±600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) DC models: ±480 V (between power terminals), and ±600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) Static immunity Malfunction: 4 kV Destruction: 8 kV Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude each in three directions Malfunction: 10 to 55 Hz with 0.5-mm single amplitude each in three directions Shock resistance Destruction: 1,000 m/s 2 (approx. 100G) each in three directions Malfunction: 100 m/s2 (approx. 10G) each in three directions Ambient temperature Operating: –10° C to 55°C (with no icing) Storage: –25° C to 65°C (with no icing) Ambient humidity Operating: 35% to 85% Life expectancy Mechanical: 10 million operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) Mechanical: 10 million operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) Case color Light gray (Munsell 5Y7/1) Enclosure ratings IEC: IP40 (panel surface) Weight Approx. 95 g

Solid-state Timer H3BA-N 5 Nomenclature H3BA-N H3BA-N8H H3BA UP PW MODE A sec 1 2 0.5 2.5 1.5 Power Indicator (Green): Lit when Timer operates. Operating Mode Display Window Operating Mode Selector: Select a mode from A, B, B2, C, D, E, G, and J. Scale Range Display Windows Time Unit Selector Select a unit from sec, 10 s, min, 10 m, hrs, and 10 h. Time setting knob (set time) Output Indicator (Orange): Lit when Timer outputs. Time Range Selector: Select one from H3BA UP PW MODE A sec 1 2 0.5 2.5 1.5 Power Indicator (Green): Lit when Timer operates. Output Type Display Window Output Type Selector: Select a type from A and H A: Time-limit DPDT (default setting) H: Time-limit SPDT and instantaneous SPDT Scale Range Display Windows Time Unit Selector Select a unit from sec, 10 s, min, 10 m, hrs, and 10 h. Time setting knob (set time) Output Indicator (Orange): Lit when Timer outputs. Time Range Selector: Select one from

6 Solid-state Timer H3BA-N

■Block Diagrams ■I/O Functions AC (DC) input Power supply circuit Oscillation circuit Time range/ unit selectors Counting circuit Operating mode selector Output circuit Reset input, start input, and gate input Input circuit Indicator circuit Power-ON indicator Output-ON indicator H3BA-N Instantaneous output circuit AC (DC) input Power supply circuit Oscillation circuit Time range/ unit selectors Counting circuit Output circuit Output type selector Indicator circuit Power-ON indicator Output-ON indicator H3BA-N8H Inputs Start Starts time-measurement. Reset Interrupts time-measurement and resets time-measurement value. No time-measurement is made and control output is OFF while the reset input is ON. Gate Prohibits time-measurement. Outputs Control output Outputs are turned ON according to designated output mode when preset value is reached.

Solid-state Timer H3BA-N 7 ■Basic Setting Setting of Selector The selectors can be turned clockwise and counterclockwise to select the desired time unit, time range, output type (only for H3BA- N8H) or operating mode. Each selector has a snap mechanism that secures the selector at a given position. Set the selector at a position at which it is secured. Do not set it midway between two securing positions or a malfunction could result from improper setting. Selection of Operating Mode with H3BA-N Turn the operating mode selector with a screwdriver until the desired operating mode (A, B, B2, C, D, E, G, or J) appears in the display window located above the selector. Selection of Output Type with H3BA-N8H Turn the output type selector with a screwdriver until the desired out- put type (A or H) appears in the display window located above the selector. Selection of Time Unit and Time Range The desired time unit (sec, 10 s, min, 10 m, hrs, or 10 h) is displayed in the window below the time setting knob by turning the time unit selector located at the lower right corner of the front panel. A time range (1.2, 3, 12, or 30) is selected with the time range selector at the lower left corner of the front panel, and the selected time range appears (in the window at the lower right part) within the plastic frame of the time setting knob. Setting of Time Use the time setting knob to set the desired time. ■Using the Setting Ring Setting a Specific Time Mount the Panel Cover on the Timer, set the desired time with the time setting knob, and place Time Setting Ring A onto the time setting knob so that the time setting notch of Time Setting Ring A is in the center of the reset lock position of the Panel Cover. Limiting the Setting Range Example: To set a range of 10 and 20 s. Mount the Panel Cover on the Timer, set the time setting knob to 10 s (the lower limit of the setting range), and place Time Setting Ring C onto the time setting knob so that the stopper of Time Setting Ring C is on the right edge of the reset lock position of the Panel cover. Next, set the time setting knob to 20 s (the upper limit of the setting range), place Time Setting Ring B onto the time setting knob so that the stopper of Time Setting Ring B is on the left edge of the reset lock position of the Panel Cover. Groove for screwdriver Operating mode/ Output type display window Operating mode selector/ Output type selector Operating mode display window Time unit selector Time unit display window Time range selector Time setting notch Reset lock position Time setting ring A Panel cover Example: To set the time to 10 s. Time setting notch Setting position Stopper Reset lock position Time setting ring B Time setting ring C Panel cover Range

8 Solid-state Timer H3BA-N

■Timing Chart Note: 1. The minimum power-opening time (“Rt”) is 0.1 s and the minimum pulse width is 0.05 s. 2. The letter “t” in the timing charts stands for the set time and “t–a” means that the period is less than the time set. H3BA-N Operating mode Timing chart A: ON-delay B: Flicker OFF start B2: Flicker ON start C: Signal ON/OFF-delay Power Start Output t Basic operation Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay (NC) 1 and 4 (11 and 8) Output relay (NO) 1 and 3 (11 and 9) and output indicator Power indicator t t Basic operation Power Start Output t t t t tt tt t - a t Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay (NC) 1 and 4 (11 and 8) Output relay (NO) 1 and 3 (11 and 9) and output indicator Power indicator Basic operation Power Start Output t t t t ttt t t - a t Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 (11 and 8) (NC) Output relay (NO) (Output indicator) 1 and 3 (11 and 9) Power indicator Basic operation Power Start Output t t t t t t t t t - a t - a t - a Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 (11 and 8) (NC) Output relay (NO) (Output indicator) 1 and 3 (11 and 9) Power indicator

Solid-state Timer H3BA-N 9 D: Signal OFF-delay E: Interval G: Signal ON/OFF-delay J: One-shot output Operating mode Timing chart Basic operation Power Start Output t t - a tt - a t - at Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 (11 and 8) (NC) Output relay (NO) (Output indicator) 1 and 3 (11 and 9) Power indicator Power Start Output t Basic operation t t t tt - a t - a Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 (11 and 8) (NC) Output relay (NO) (Output indicator) 1 and 3 (11 and 9) Power indicator t t t t Basic operation Power Output Start (See note) Note: Start input is valid and retriggerable while the Timer is in operation. Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 (11 and 8) (NC) Output relay (NO) (Output indicator) 1 and 3 (11 and 9) Power indicator t Basic operation Output Power 1±0.6 s (Fixed) 1±0.6 s (Fixed) Start (See note) 1±0.6 s (Fixed) Note: Start input is valid and retriggerable while the Timer is in operation. (Previous start input will be cancelled.) Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 (11 and 8) (NC) Output relay (NO) (Output indicator) 1 and 3 (11 and 9) Power indicator

10 Solid-state Timer H3BA-N

Gate Signal Input in Operating Mode A (ON-delay Operation) Note: The set time is the sum of t1 and t2. H3BA-N8H, Output Type: A Type H3BA-N8H, Output Type: H Type Power Start Gate Reset Output relay ON OFF ON OFF ON OFF ON OFF ON OFF t1 t2 Operating mode Timing chart A: ON-delay Power Output t Basic operation Power 2 and 7 Output relay (NC) 8 and 5 (1 and 4) Output relay (NO) 8 and 6 (1 and 3) and output indicator Power indicator t tRt Rt t - a Operating mode Timing chart H: ON-delay with instantaneous output contact Power Output t Basic operation Power 2 and 7 Output relay 8 and 5 (NC) Power indicator Instantaneous 1 and 4 output relay (NC) t tRt Rt t - a Instantaneous 1 and 3 output relay (NO) Output relay 8 and 6 (NO) (output indicator)

Solid-state Timer H3BA-N 11 Dimensions Note: All units are in millimeters unless otherwise indicated. H3BA-N H3BA-N8H Dimensions with Set Ring Dimensions with Y92F-30 Flush Mounting Adapter 11 pins 6 63.7 0.7 39 dia. 44.8 × 44.8 13.6 PW UP 8 pins 6 63.7 0.7 39 dia. 44.8 × 44.8 13.6 PW UP Time setting ring Panel cover 50 16.5 50 42 dia. Panel Cutout Note: The mounting panel thickness should be 1 to 5 mm. 0.5 R max. 45+0.6 (N) 45+0.6 58 52 Panel P3G Back Connecting Socket (sold separately) PW UP

12 Solid-state Timer H3BA-N

Dimensions with Y92F-70 Flush Mounting Adapter Dimensions with Y92F-71 Flush Mounting Adapter Track Mounting Note: These dimensions vary with the kind of DIN track (reference value). Flush Mounting Panel 45±0.15 45± 0.15 Panel Cutout Adapter mounting hole Two, 4.5 dia. 52 to 53 76±0.265 to 66 R0.5 max. PW UP Panel 43±0.2 50+0.2 R0.5 max. 45+0.5 55+0.5 Note: The mounting panel thickness should be 1 to 3.2 mm. 45±0.2 Panel Cutout PW UP 112.2* 109.9 2.3* H3BA-N P2CF-11 H3BA-N8H P2CF-08 101.3* 99 2.3* H3BA-N Adapter Y92F-30 P3GA-11 91.4 H3BA-N8H Y92F-30 P3G-08 86.4

Solid-state Timer H3BA-N 13 ■Accessories (Order Separately) Track Mounting/Front Connecting Socket Back Connecting Socket Mounting Track P2CF-08 P2CF-11 Terminal Arrangement/ Internal Connections (Top View) Surface Mounting Holes 40±0.2 Two, 4.5 dia. or two, M4 Two, 4.5 dia. or two, M4 40±0.2 Eight, M3.5 × 7.5 sems Two, 4.5 dia. holes 70 max. 50 max. 20.3 max. 7.8 3 4.5 35.4 Two, 4.5 dia. holes Eleven, M3.5 × 7.5 sems 70 max. 50 max. 31.2 max. 7.8 3 4.5 35.4 P3G-08 P3GA-11 Terminal Arrangement/ Internal Connections (Bottom View) 27 dia. 45 4.9 17 27 dia. 25.6 4.5 16.3 6.2 PFP-100N, PFP-50N PFP-100N2 L: Length 1 m PFP-100N 50 cm PFP-50N 1 m PFP-100N2 4.5 15 25 25 25 25 * 10 10 L 7.3±0.15 35±0.3 27±0.15 4.5 15 25 25 25 25 15 10 10L 35±0.3 27 24 29.2 1 1.5

14 Solid-state Timer H3BA-N

The protective cover protects the front panel, particularly the time setting section, against dust, dirt, and water. It also prevents the set value from being altered due to accidental contact with the time setting knob. Note: 1. The Y92A-48B Protective Cover is made of a hard plastic and therefore it must be removed to change the timer set value. 2. The Protective Cover cannot be mounted if the Panel Cov- er (sold separately) is used on the Timer. Y92A-48B Time Setting Ring/Panel Cover There are two types of Panel Covers (Y92P-48GL, Y92P-48GB), all of which are available in two colors. Use the most suitable type of Panel Cover with the design of the scaling plate according to the application. When setting a given time for the Timer, use of the Y92S-27 or Y92S-28 Time Setting Ring facilitates the time setting operation and minimizes possible setting errors by operators. The Time Setting Ring and Panel Cover should be used as a pair.Hold-down Clip PFP-M 11.5 M4 × 8 pan head screw 6.2 1.8 35.5 35.3 1.8 1.3 4.810 PFP-S 44.3 34.8 16.5 PW UP Setting a specific time Time Setting Ring A (Y92S-27) and Panel Cover (Y92P-48GL, -48GB) Limiting the setting range Time Setting Ring B or C (Y92S-28), and Panel Cover (Y92P-48GL, -48GB) Y92S-27 Time Setting A Y92S-28 Time Setting B Y92P-48GL Light Gray Y92P-48GB Black Y92S-28 Time Setting C Y92H-1 For PL08 Socket Y92H-2 For PF085A Socke t

Solid-state Timer H3BA-N 15 Installation ■Terminal Arrangement H3BA-N (Contact Output) Reset input Start input Gate input (–)(~) (+)(~)Power supply H3BA-N8H (Contact Output) Note: The delayed contacts of conventional timers are shown as follows: The contact symbol of the H3BA-N is ex- pressed as follows because of its multiple op- erating modes: The instantaneous contacts of conventional timers are shown as follows: (−)(~) (+)(~) Power supply MODE (See note.) A H Note: The output contact can be set to either instantaneous or time-limit contact using the output type selector located at the upper right corner of the front panel.

16 Solid-state Timer H3BA-N

■Input Connections The inputs of the H3BA-N are no-voltage (short circuit or open) inputs. No-voltage Inputs No-voltage Input Signal Levels No-contact input Contact input 1. Short-circuit level Transistor ON Residual voltage: 1 V max. Impedance when ON: 1 kΩ max. 2. Open level Transistor OFF Impedance when OFF: 200 kΩ min. Use contacts which can adequately switch 0.1 mA at 5 V No-contact Input (Connection to NPN open collector output sensor.) Contact Input No-contact Input (Connection to a voltage output sensor.) 12 to 24 VDC (sensor power supply) Sensor Timer Start/reset/ gate Input (0 V) (No. 2 pin) Operates with transistor ON DC power supply Timer Start/reset/ gate Input (0 V) (No. 2 pin) Operates with relay ON 12 to 24 VDC (sensor power supply) Sensor Timer Start/reset/ gate Input (0 V) (No. 2 pin) Operates with transistor ON DC power supply

Solid-state Timer H3BA-N 17 Safety Precautions Warning Indications Meaning of Product Safety Symbols ■Precautions for Safe Use Please observe the following precautions for safe use of this product. Environmental Precautions Store the Timer within specified ratings. If the Timer has been stored at -10°C or lower, let it stand for 3 hours or longer at room temperature before turning ON the power supply. Use the Timer within the specified ratings for operating temperature and humidity. Do not operate the Timer in locations subject to sudden or extreme changes in temperature, or locations where high humidity may result in condensation. Do not use the Timer in locations subject to excessive dust, corrosive gas, or direct sunlight. Do not use the Timer in locations subject to vibration or shock. Extended use in such locations may result in damage due to stress. Install the Timer well away from any sources of static electricity, such as pipes transporting molding materials, powders, or liquids. Usage Precautions Install a switch or circuit breaker that allows the operator to immediately turn OFF the power, and label it to clearly indicate its function. Pay careful attention to polarity to prevent wrong connections when wiring terminals. Internal elements may be destroyed if a voltage outside the rated voltage is applied. Maintain voltage fluctuations in the power supply within the specified range. The Timer uses a transformerless power supply. Do not touch the input terminals while the supply voltage is being applied, otherwise an electric shock may occur. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. Precautions for Safe Use Supplementary comments on what to do or avoid doing, to use the product safely. Precautions for Correct Use Supplementary comments on what to do or avoid doing, to prevent failure to operate, malfunction or undesirable effect on product performance. Used to warn of the risk of electric shock under specific conditions. Used to warn of the risk of minor injury caused by high temperatures Used for general mandatory action precautions for which there is no specified symbol. Use to indicate prohibition when there is a risk of minor injury from electrical shock or other source if the product is disassembled. Minor electric shock may occasionally occur. Do not disassemble the product or touch the interior of the Timer. Minor burns may occasionally occur. Do not touch the product while power is being supplied or immediately after power is turned OFF . Minor fires may occasionally occur. Tighten terminal screws to a torque of 1.08 N·m so that they do not become loose. Minor electric shock may occasionally occur during operation. Install the terminal cover. Minor electric shock, fire, or malfunction may occasionally occur. Do not allow metal fragments, lead wire scraps, or chips from processing during installation to fall inside the Timer. CAUTION

18 Solid-state Timer H3BA-N

■Precautions for Correct Use Changing the Setting Do not change the time unit, time range, or operation mode while the Timer is in operation, otherwise the Timer may malfunction. Connecting the Operating Power Supply The H3BA-N@ contains a capacitor-drop power circuit. Use a sinusoidal power supply with a commercial frequency. Do not use power supplies with a high frequency component (such as inverter power supplies) for Timers with 110 or 220-VAC specifications. Using these power supplies can damage internal circuits. If voltages other than the rated voltage is applied, the internal components may be damaged. The internal element (varistor) will be damaged if a voltage of higher than 100 VAC is applied to the 24- VDC line. Connect the power supply voltage through a relay or switch in such a way that the voltage reaches a fixed value immediately or the Timer may not be reset or a timer error could result. A DC power supply can be connected if its ripple factor is 20% or less and the mean voltage is within the rated operating voltage range of the Timer. If the wiring to the terminal 2 (common terminal for both the power supply and input signals) is broken, the internal circuit will be destroyed. Input/Output An appropriate input will be applied to the input signal terminals of the Timer when one of the input terminals (terminals 5, 6, and 7) and the common terminal (terminal 2) for the input signals are short- circuited. Do not attempt to connect any input terminal to any terminal other than the common terminal or to apply voltage across other than the specified input and common terminals or the internal circuits of the Timer may be damaged. Note: 1. Power supply terminal 2 is a common terminal for the input signals (G, S, R) to the Timer. Never use terminal 10 as the common terminal for this purpose, otherwise the internal circuit of the Timer may be damaged. 2. Do not connect a relay or any other load between these two points, otherwise the internal circuit of the Timer may be damaged due to the high-tension voltage applied to the input terminals. Operating Time Setting When setting the operating time, do not turn the setting knob beyond its scale range. For precise time setting, conduct operation tests by adjusting the setting knob. The accuracy of the operating time of the Analog Timer is indicated by the percentage value on the basis of the full-scale time. The absolute fluctuation value will not be improved by changing the time setting. Therefore, when selecting the model, be sure that the application will be able to use a time setting as close as the full-scale time setting of the Timer. Others When conducting a dielectric test, impulse voltage test, or insulation resistance test between the electric circuit and non-current-carrying metal parts of the Timer mounted to a control panel, be sure to take the following steps. These steps will prevent the internal circuitry of the Timer from damage that may be caused if a machine on the control panel has an improper dielectric strength or insulation resistance. 1. Separate the Timer from the circuitry of the control panel by disconnecting the socket from the Timer or wires. 2. Short-circuit all terminals of the Timer. If any device with no-contact output, such as a proximity sensor, photoelectric sensor, or SSR, is directly connected to the Timer, current leakage from the device may cause Timer malfunction. Be sure to test the device with the Timer before using the device for actual applications. Before using the Timer to switch inductive loads, be sure to connect a surge absorbing element to the Timer in order to prevent the Timer from malfunction and damage. A diode is an example of a surge absorbing element for DC circuits and a surge absorber is an example of a surge absorbing element for AC circuits. Do not leave the Timer in time-up condition for a month or longer in places with high temperatures, otherwise the internal parts, such as an electrolytic capacitor, of the Timer may be damaged. Use the Timer with an appropriate relay so that the Timer will not be left in time-up condition for a long time. If the Timer is mounted in contact with a mounting surface, the service life of internal parts may be shortened. Provide at least 10 mm between the Timer and the mounting surface to prolong the service life of the Timer. When the Timer is reset right after the Timer goes into time-up condition, be sure to provide the Timer with an appropriate circuit configuration considering the resetting time of the Timer so that a sequential error will not result. The Timer uses the constant value read method. Be careful when changing the set value because the output of the Timer will be ON when the set value coincides with the count value. Be sure that the casing of the Timer is free from organic solvents, such as paint thinner and benzene, strong acid, and alkali solvents, which will damage the casing. Note: It is impossible to connect more than two Timers in parallel. 5, 6, 7 G, S, R Input terminal H3BA-N Closed Power supply AC or DC Input contact 5, 6, 7 G, S, R Input terminal H3BA-N (See note 2) 2 (see note 1)

Solid-state Timer H3BA-N 19 ■Mounting Surface Mounting There is no particular restriction on surface mounting directions, but be sure that the Timer is securely mounted horizontally. P2CF Socket When mounting the Timer vertically with the P2CF Socket, consider the movable hooks and be sure that there is a 20-mm space on each of the upper and lower parts of the Socket.PL Socket 1. Secure the Socket to the panel surface with screws and insert the F-shaped hook into the sockets. 2. Connect the Timer to the Socket and press the tip of each hook by hand. Panel Mounting When the Y92F-30 Flush Mounting Adapter is used, insert the Timer into the square hole from the front side of the panel and put on the Flush Mounting Adapter from the rear side of the Timer. Press the Flush Mounting Adapter so that the space between the Flush Mounting Adapter and the panel is reduced as much as possible, and secure the Flush Mounting Adapter with screws. When using the US08, be sure to use 10.5-dia. max. multi-conductor cable or 3-dia. max. insulated stranded wire for wiring. When the Y92F-30, Y92F-70 or Y92F-71 Flush Mounting Adapter is used, just insert the Timer into the square panel hole. If the panel coating is too thick and the hooks do not click, spread open the hooks appropriately to the left and right after inserting the Timer to the hole. ■Dismounting Surface Mounting with P2CF Panel Mounting Loosen the screws of the Flush Mounting Adapter, spread open the hooks, and remove the Mounting Adapter. When the Y92F-30, Y92F-70, Y92F-71 Mounting Adapter is used, press the hook inwards with the thumb and index finger of both hands, and press the Timer towards the front side. Duct Hook Panel P2CF-08 Panel Screw Y92F-30 Spread open the hooks to the left and right. Spread open the hooks to the left and right. Panel The illustration is an ex ample with the Y92F-70.

20 Solid-state Timer H3BA-N

Read and Understand this Catalog Please read and understand this catalog before purchasing the product. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY , OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABL Y MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY , NEGLIGENCE, OR STRICT LIABILITY . In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY , REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANAL YSIS CONFIRMS THAT THE PRODUCTS WERE PROPERL Y HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the product in the customer's application or use of the product. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERL Y RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.

Authorized Distributor: In the interest of product improvement, specifications are subject to change without notice. Cat. No. L093-E1-03 0313 (1197) (O) © OMRON Corporation 1997 All Rights Reserved. OMRON Corporation Industrial Automation Company OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Contact: www.ia.omron.com Tokyo, JAPAN OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower,

200 Yin Cheng Zhong Road,

PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 CSM_1_4_1018