H16WD6025G-10 CRYDOM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 7
Technical content
- Ratings from 25A to 90A @ 48-690 VAC
- 1600 Volts Blocking
- SCR output for heavy industrial loads
- Zero voltage or instantaneous turn-on outputs
- UL/CSA/VDE Approved, CE Compliant to EN60950-1
- Improved SEMS screw and washer
- Redesigned housing with anti-rotation barriers For Generation 3 datasheet click here
- DC control
- Direct Bond Copper substrate
- EMC Compliant to Level 3
- Direct Power Lead Frame
- Epoxy Free Design PRODUCT SELECTION 90A75A50A25AControl Voltage 4-32 Vdc H16WD6025 H16WD6050 H16WD6075 H16WD6090 AVAILABLE OPTIONS Required for valid part number For options only and not required for valid part number Thermal Pad Blank: Not Included H: Included Series Transient Overvoltage 6WD: 1600 Vpk Rated Load Current 25: 25 Amps 50: 50 Amps 75: 75 Amps 90: 90 Amps Switching Type Blank: Zero Voltage Turn-On -10: Instantaneous Turn-On Input Status LED Blank: Not Included G: Included Termination Blank: Screw F: Quick Connect (Up to 50 Amps models) K: Hex standoffs Operating Voltage 60: 48-690 VAC 60H1 25 K G H -106WD (3) (2) (1) Not all part number combinations are available. Contact Crydom Technical Support for informacion on the availability of a specific part number. OUTPUT SPECIFICATIONS (4) Description 25A 50A 75A 90A Operating Voltage (47-440Hz) [Vrms] 48-690 48-690 48-690 48-690 Transient Overvoltage [Vpk] 1600 1600 1600 1600 Rated Load Current [Arms] (5)(2) 25 50 75 90 Rated Load Current {UL508 Motor Controller} [Arms] (5) 10 20 30 45 Minimum Load Current [mArms] 150 150 150 150 Maximum Off-State Leakage Current @ Rated Voltage [mArms] 1.0 1.0 1.0 1.0 Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] 500 500 500 500 Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 239/250 597/625 954/1000 1145/1200 Maximum I²t for Fusing (50/60Hz) [A² sec] 285/259 1779/1621 4555/4150 6560/5976 Thermal Resistance Junction to Case (Rjc) [°C/W] 0.8 0.45 0.3 0.27 Maximum On-State Voltage Drop @ Rated Current [Vrms] 1.3 1.3 1.2 1.2 HP rating UL 508/IEC60947[HP (KW)]: 480 VAC 3 (2.2) 5 (3.7) 10 (7.4) 20 (14.9) HP rating UL 508/IEC60947[HP (KW)]: 600 VAC 3 (2.2) 10 (7.4) 15 (11.2) 25 (18.6) Minimum Power Factor (at Maximum Load) 0.5 0.5 0.5 0.5 Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. DatasheetPanel Mount
INPUT SPECIFICATIONS(4) Description DC Control Control Voltage Range 4-32 VDC Must Turn-Off Voltage 1.0 VDC Maximum Reverse Voltage -32 VDC Minimum Input Current @ Minimum Voltage (for on-state) 7mA Maximum Input Current @ Maximum Voltage 12mA Nominal Input Impedance Current Regulated Maximum Turn-On Time [msec] (7) 1/2 Cycle Maximum Turn-Off Time [msec] 1/2 Cycle GENERAL SPECIFICATIONS LED Input Status Indicator w/”G” option (green) (4) Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms Minimum Insulation Resistance (@ 500 VDC) 109 Ohm Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range -30 to 80 °C Ambient Storage Temperature Range -40 to 125 °C Weight (typical) 2.6 oz (74.9 g) Housing Material UL 94 V-0 SSR Mounting Torque Range [in lbs/Nm] 18-20 (2-2.2) Baseplate Material Aluminum Input Terminal Screw Torque Range [in-lb/Nm] 13-15 /1.5-1.7 Output Terminal Screw Torque Range [in lb/Nm] 18-20 (2-2.2) SSR Mounting Screw Torque Range [in-lb/Nm] 18-20 / 2.0-2.2 Input/Load Terminal Screw Torque Range [in-lb/Nm] (2) w/”K” option 8-10 / 0.9-1.13 Humidity per IEC60068-2-78 93% non-condensing MTBF (Mean Time Between Failures) at 40°C ambient temperature (8) 11,641,553 hours (1,328 years) MTBF (Mean Time Between Failures) at 60°C ambient temperature (8) 7,210,376 hours (823 years) WIRING DIAGRAM AC V Load (9) 1 ( ) 2 ( ) 1 2OUTPUT S OLI D S T A T E R ELA Y 4 3INPUT 4 (–) 3 (+) Recommended Wire Sizes Terminals Wire Size (Solid / Stranded) Wire Pull-Out Strength (lb)[N] Input Output 24 AWG (0.2 mm 2) / 0.2 [minimum] 2 x 12 AWG (3.3 mm 2) / 3.3 [maximum] 20 AWG (0.5 mm 2) / 0.518 [minimum] 2 x 10 AWG (5.3 mm 2) / 5.3 2 x 8 AWG (8.4 mm 2) / 8.4 [maximum] 10 [44.5] 90 [400] 30 [133] 110 [490] 90 [400] Input Current vs Input Voltage Standard Regulated DC Input Input Current (mA) DC Input Voltage 0 5 10 15 20 25 30 +DC -DC AC Trigger Circuit Current Limiter AC (10) EQUIVALENT CIRCUIT BLOCK DIAGRAM Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. DatasheetPanel Mount Input/Output Terminal Screw Thread Size #6-32 UNC / #8-32 UNC Minimum Turn-On Voltage (6) 4.0 VDC
MECHANICAL SPECIFICATIONS (4) Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] GENERAL NOTES For additional information or specific questions, contact Crydom Technical Support. Screw Termination
1 OUTPUT 2
4 INPUT 3
1.1 [27.9] 0.49 [12.4] Mounting Hole/Slot 0.19 [4.9] DIA. 0.89 [22.6] 1.88 [47.6] 1.7 [43.2] 2.25 [57.3] 1.0 [25.4] 1.75 [44.5] Hex Standoff Termination (“K” Option) 1.1 [27.9] 0.49 [12.4] Mounting Hole/Slot 0.19 [4.9] DIA. 1.04 [26.4] 1.88 [47.6] 1.70 [43.2] 2.25 [57.3] 1.0 [25.4] 1.75 [44.5] 0.93 [23.6] (4 places) 1.0 [25.4] (2 places) (2) Quick Connect Termination (“F” Option) - Up to 25 Amp (1) 0.19 [4.9] DIA. 1.58 [40.2] 0.49 [12.4] Faston Terminal(11) 0.25 x 0.032 (2 places) 1.31 [33.4] 1.88 [47.6] 1.7 [43.2] 2.25 [57.3] 1.40 [35.6] 1.75 [44.5] Faston Terminal(11) 0.187 x 0.020 (2 places) 1.25 [31.8] Quick Connect Termination (“F” Option) - Up to 50 Amp (1) S OLI D S T A T E R ELA Y OUTPUT INPUT Mounting Hole/Slot 0.19 [4.9] DIA. 1.58 [40.2] 0.49 [12.4] Faston Terminal(11) 0.25 x 0.032 (4 places) 1.31 [33.4] 1.88 [47.6] 1.7 [43.2] 2.25 [57.3] 1.40 [35.6] 1.75 [44.5] Faston Terminal(11) 0.187 x 0.020 (2 places) 1.25 [31.8] 0.63 [16.0] 0.45 [11.4] (2 places) Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. DatasheetPanel Mount (1) Single pair (up to 25A) Double pair* (50A model only). *Caution: User must connect to both pairs. For higher load currents, the “K” standoff temperature must not exceed 105°C. For additional application assistance please contact Crydom Technical Support. (3) Instantaneous turn-on version is not recomended for capacitive loads. Use zero turn-on only. (4) All parameters at 25°C unless otherwise specified. (5) Heat sinking required, see derating curves. (6) Increase minimum voltage by 1V for operations from -20 to -30°C. (7) T urn-on time for Instantaneous turn-on versions is 0.02 msec. (8) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report) (9) Load can be wired to either SSR output terminal 1 or 2. (10) Elective Input Status LED, “G” option. (11) Mechanical dimensions vary from G3 models.
0.01 0.1 1 10 Surge Current (Amp) Surge Duration (Secs) 25 A 100 200 300 400 500 600 0.01 0.1 1 10 Surge Current (Amp) Surge Duration (Secs) 50 A 100 200 400 300 500 600 700 900 800 0.01 0.1 1 10 Surge Current (Amp) Surge Duration (Secs) 75 A 150 450 300 600 750 900 1200 1050 0.01 0.1 1 10 Surge Current (Amp) Surge Duration (Secs) 90 A Non repetitive peak surge current at Tj initial 40ºC. THERMAL DERATE INFORMATION 20 30 40 50 60 70 80 Ambient Temperature (ºC) Load Current (Amps) 25 A 1.5ºC/W 2ºC/W 3ºC/W 20 30 40 50 60 70 80 Ambient Temperature (ºC) Load Current (Amps) 50 A 0.7ºC/W 1ºC/W 1.5ºC/W 2ºC/W 20 30 40 50 60 70 80 Ambient Temperature (ºC) Load Current (Amps) 75 A 0.5ºC/W 0.7ºC/W 1ºC/W 1.5ºC/W 20 30 40 50 60 70 80 Ambient Temperature (ºC) Load Current (Amps) 90 A 0.5ºC/W 0.7ºC/W 1ºC/W 1.5ºC/W Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. DatasheetPanel Mount
Designed in accordance with the requirements of IEC 62314 IEC 61000-4-2 : Electrostatic Discharge – Level 3 IEC 61000-4-4 : Electrically Fast Transients – Level 3 IEC 61000-4-5 : Electrical Surges – Level 3 IEC 600068-2-6: Vibration 0.33mm and 0.75mm Amplitude over 10-55 Hz IEC 600068-2-27: Shock Resistance 15g/11ms E116949 ACCESORIES Part number: KS101 Clear plastic cover compatible with all new S1 designs. Safety covers provide added protection from electric shock when installing or checking equipment. Protective Cover Hardware Kit Part number: HK4 Bag with 2 square brass accessories and 2 screw 8-32 x 5/8 for output. Used to mount TMR1 lug terminals. New Accessories! Protective Cover & Hardware Kits Recommended Accessories Cover Hardware Kit Heat Sink Part No. Thermal Resistance [ºC/W] Lug Terminal Thermal Pad KS101 HK1 HK4 TRM1 TRM6 HSP-1 HSP-2 HS501DR HS301 / HS301DR HS251 HS202 / HS202DR HS201 / HS201DR HS172 HS151 / HS151DR HS122 / HS122DR HS103 / HS103DR HS101 HS073 HS072 HS053 HS033 HS023 5.0 3.0 2.5 2.0 2.0 1.7 1.5 1.2 1.0 1.0 0.7 0.7 0.5 0.36 0.25 Rev. 040616 Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. DatasheetPanel Mount
Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. DatasheetPanel Mount DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.
- Disconnect all power before installing or working with this equipment.
- Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION.
- Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo.
- Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION
- Eteindre toutes les sources d'énergie de cet appareil avant de travailler dessus de cet appareil
- Vérifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lésions sérieuses sérieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION.
- Stellen Sie jeglichen Strom ab, der dieses Gerät versorgt, bevor Sie an dem Gerät Arbeiten durchführen
- Vor dem Drehen auf Energie alle Anschlüsse überprüfen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen können zum Tode oder zu schweren Verletzungen führen. RISCHIO DI SCOSSA ELETTRICA O DELL’ESPLOSIONE.
- Spenga tutta l'alimentazione che fornisce questa apparecchiatura prima di lavorare a questa apparecchiatura
- Verificare tutti i collegamenti e sostituire tutte le coperture prima dell’accensione L'omissione di queste istruzioni provocherà la morte o lesioni serie 存在电击、 爆炸或电弧 闪烁危险
- 在操作此设 备之前请先 关闭电源。 若不遵守这些说明, 可能会导致严重的 人身伤害甚至死亡。 WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告 RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
- The product's side panels may be hot, allow the product to cool before touching.
- Follow proper mounting instructions including torque values.
- Do not allow liquids or foreign objects to enter this product. Failure to follow these instructions can result in serious injury, or equipment damage. RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER
- Les panneaux latéraux du produit peuvent être chauds. Laisser le produit refroidir avant de le toucher.
- Respecter les consignes de montage, et notamment les couples de serrage.
- Ne pas laisser pénétrer de liquide ni de corps étrangers à l'intérieur du produit. Le non-respect de cette directive peut entraîner, des lésions corporelles graves ou des dommages matériels. Die Nichtbeachtung dieser Anweisung kann Körperverletzung oder Materialschäden zur Folge haben. GEFAHR VON MATERIALSCHÄDEN UND GEHÄUSEERHITZUNG
- Die Seitenwände können heiß sein. Lassen Sie das Produkt abkühlen, bevor Sie es berühren.
- Beachten Sie die Montageanweisungen,
- Führen Sie keine Flüssigkeiten oder Fremdkörper in das Produkt ein. Si no se respetan estas precauciones pueden producirse graves lesiones, daños materiales. RIESGO DE DAÑOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD
- Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfríe antes de tocarlo.
- Respetar las instrucciones de montaje, y en particular los pares de apretado.
- No dejar que penetren líquidos o cuerpos extraños en el producto. La mancata osservanza di questa precauzione può causare gravi rischi per l'incolumità personale o danni alle apparecchiature. RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO
- I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo.
- Seguire le istruzioni di montaggio corrette.
- Non far entrare liquidi o oggetti estranei in questo apparecchio. 如不能正确执行这些操作说明, 极有可能造成严重人体伤害或者设备的损坏。 材料损坏和高温外壳的危险性
- 产品的一侧面板可能很热,在其冷却前请 不要触碰。
- 遵照正确的安装说明,包括扭矩值。
- 请勿让液体及其他异物进入本产品。
ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated (Pb) (Hg) (Cd) Chromium (Cr (VI)) biphenyls (PBB) diphenyl ethers (PBDE) Semiconductor die Solder 附件 - 环保信息 此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006, 电子信息产品污染控制标识要求。 有毒有害物质或元素件部 名称 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE) 半导体芯片 焊接点 Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. DatasheetPanel Mount