Product: H16G1.0CH MachFlex™ 610CH, 15+1G C 1.0mm² Str BC, LSZH Ins, LSZH Inner Jkt, TCBS, LSZH Outer Jkt, UL AWM Style 21115 Product Description MachFlex™ 610CH, 15 Conductor + 1 Ground 1.0mm² Stranded Bare Copper, LSZH Insulation, LSZH Inner Jacket, Tinned Copper Braid Shield, LSZH Outer Jacket, UL AWM Style 21115 Technical Specifications Product Overview Suitable Applications: Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, multi axis control machines, temperature controllers, control panels, machine cutting tools, auxiliary equipment, motor speed control, production machinery and many more. Tinned copper braid shield ensures cables with excellent noise immunity. Utilizing LSZH material emits limited smoke and no halogen when exposed to high sources of heat. It can considerably reduce the amount and density of the smoke, toxic and corrosive gas emitted during a fire, enable easier evacuation as well as safer firefighting operations. Construction Details Conductor Element Size Stranding Material Conductor(s) 1 mm² Class 5 BC - Bare Copper Ground 1 mm² Class 5 BC - Bare Copper Insulation Material Color Code LSZH - Low Smoke Zero Halogen (Flame Retardant) Black #1, Black #2, Black #3, Black #4, Black #5, …, Black #15, Green/Yellow Outer Shield Shield Type Material Braid Tinned Copper (TC) Outer Jacket Material Nom. Diameter LSZH - Low Smoke Zero Halogen (Flame Retardant) 16.21 mm

Electrical Characteristics

Max. Conductor DCR 19.5 Ohm/km (5.94 Ohm/1000ft) Voltage Voltage Rating 600/1000 V (IEC:) Mechanical Characteristics Temperature Operating Installation 25°C to +70°C -40°C to +80°C Bend Radius

Installation Min. 6 x OD Bulk Cable Weight: 441 kg/km (296 lbs/1000ft) Standards and Compliance Environmental Suitability: Indoor, Outdoor, Sunlight Resistance, UV Resistance, Oil Resistance, Oil Resistance Flammability / Reaction to Fire: IEC 60332-1-2, DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-3-24, IEC 60332-3-25 AWM Compliance: AWM 21115 European Halogen Free Standards: IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 µS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3 European Directive Compliance: EU Directive 2011/65/EU (RoHS 2) History Update and Revision: Revision Number: 0.19 Revision Date: 07-15-2024 Part Numbers Variants Item # Color Length H16G1.0CH 010200M Black, RAL 9005 200 m H16G1.0CH 010305M Black, RAL 9005 305 m H16G1.0CH 010500M Black, RAL 9005 500 m H16G1.0CH 0101000M Black, RAL 9005 1,000 m H16G1.0CH G8U200M Gray, RAL 7001 200 m H16G1.0CH G8U305M Gray, RAL 7001 305 m H16G1.0CH G8U500M Gray, RAL 7001 500 m H16G1.0CH G8U1000M Gray, RAL 7001 1,000 m H16G1.0CH 003200M Orange, RAL 2003 200 m H16G1.0CH 003305M Orange, RAL 2003 305 m H16G1.0CH 003500M Orange, RAL 2003 500 m H16G1.0CH 0031000M Orange, RAL 2003 1,000 m © 2024 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.