Features
- Independently controlled dual output solid-state relay
- Ratings from 25A to 40A @ 24-530 VAC
- Industry standard package
- SCR output for heavy industrial loads
- DC Control
- Zero voltage (resistive loads) or instantaneous turn-on (inductive loads) output Control Voltage 25 A 40 A 4-15 VDC Control D2425D D2440D 15-32 VDC Control D2425DE D2440DE 4-15 VDC Control H12D4825D H12D4840D 15-32 VDC Control H12D4825DE H12D4840D Output (1) Description D2425xx D2440xx H12D4825xx H12D4840xx Operating Voltage (47-63 Hz) [Vrms] 24-280 24-280 48-530 48-530 Transient Overvoltage [Vpk] 600 600 1200 (2) 1200 (2) Maximum Off-State Leakage Current @ Rated Voltage [mArms] 10 10 10 10 Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3) 500 500 500 500 Maximum Load Current [Arms] (4) 25 40 25 40 Minimum Load Current [Arms] 0.15 0.15 0.15 0.15 Maximum 1 Cycle Surge Current (50/60 Hz) [Apk] 239/250 597/6250 239/250 597/625 Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 Thermal Resistance Junction to Case (Rjc) [°C/W] 1.02 0.63 1.02 0.63 Maximum 1/2 Cycle I²t for Fusing (50/60 Hz) [A² sec] 285/259 1779/1621 285/259 1779/1621 Minimum Power Factor (with Maximum Load) 0.5 0.5 0.5 0.5
www.sensata.comCopyright © 2024 Sensata Technologies, Inc. Input (1) Description D24XXD H12D48XXD E SUFFIX Control Voltage Range 4-15 VDC 4-15 VDC 15-32 VDC Minimum Turn-On Voltage 4.0 VDC 4.0 VDC 15.0 VDC Minimum Turn-Off Voltage 1.0 VDC 1.0 VDC 1.0 VDC Typical Input Current @ 5 VDC (@ 24 VDC for E Suffix) 13 mA 13 mA 15 mA Nominal Input Impedance [Ohm] 300 240 1500 Maximum Turn-On Time [msec] (5) 1/2 Cycle 1/2 Cycle 1/2 Cycle Maximum Turn-Off Time [msec] 1/2 Cycle 1/2 Cycle 1/2 Cycle General (1) Description Parameters Dielectric Strength, Input/Output (50/60 Hz) 4000 Vrms Minimum Insulation Resistance (@ 500 VDC) 109 Ohms Maximum Capacitance, Input/Output 10 pF Ambient Operating Temperature Range -40 to 80°C Ambient Storage Temperature Range -40 to 125 °C Weight (typical) 3.0 oz (86.5g) Encapsulation Thermally Conductive Epoxy Terminals .25” Fastons, .025” Square Pins MECHANICAL SPECIFICATIONS Tolerance: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters]
www.sensata.comCopyright © 2024 Sensata Technologies, Inc. WIRING DIAGRAM THERMAL DERATE INFORMATION
www.sensata.comCopyright © 2024 Sensata Technologies, Inc. ORDERING OPTIONS Example : H12D4825DH-10 Series Output Voltage D24 : 24-280 VAC H12D48 : 48-530 VAC Rated Load Current 25 : 25 Amps 40 : 40 Amps Control Voltage D : 4-15 VDC DE : 15-32 VDC Thermal Pad Blank : Not Included H : Included Switching Mode Blank : Zero Voltage Turn-On -10 : Instantaneous Turn-On H12D48 25 D H -10 GENERAL NOTES (1) All parameters at 25°C unless otherwise specified. (2) For option (-10) models the Transient overvoltage is 1100Vac. (3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 (4) Heat sinking required, for derating curves see next page. (5) Turn-on time for Instantaneous turn-on (-10) versions is 0.1 msec AGENCY APPROVALS & CERTIFICATIONS Designed in accordance with the requirements of IEC 62314 Required for valid part number For options only and not required for valid part number
+1(800) 350 2727 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 www.sensata.com CONTACT USCopyright © 2024 Sensata Technologies, Inc. Datasheets provided by Sensata Technologies, Inc., its subsidiaries and/or affiliates (“Sensata”) are solely intended to assist third parties (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer’s systems and products. Sensata datasheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular datasheet. Sensata may make corrections, enhancements, improvements, and other changes to its datasheets or components without notice. Buyers are authorized to use Sensata datasheets with the Sensata component(s) identified in each particular datasheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATASHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATASHEETS OR USE OF THE DATASHEETS, EXPRESS, IMPLIED, OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATASHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com. SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY , AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA Rev:07/02/2024 ECN 21026 FDE-07-01 Rev. B WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
- The product’s side panels may be hot, allow the product to cool before touching
- Follow proper mounting instructions including torque values
- Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
- Disconnect all power before installing or working with this equipment
- Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury.