H12D4825DE ETC1 | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
MODEL NUMBERS D2425D D2440D H12D4825D H12D4840D OU TP U T SPE C IFIC A TION S ➀ Operating Voltage (47-63 Hz) [Vrms] 24-280 24-280 48-530 48-530 Load Current Range ➂ [Arms] .15-25 .15-40 .15-25 .15-40 Transient Overvoltage [Vpk] 600 600 1200 1200 Max. Surge Current, (16.6ms) [Apk] 250 625 250 625 Thermal Resistance Junction to Case (RθJC) [ûC/W] ➀ 1.02 .63 1.02 .63 Maximum I2 t for Fusing, (8.3 msec.) [A2sec] 260 1620 260 1620 Max. Off-State Leakage Current @ Rated Voltage [mArms] 10 10 10 10 Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁ 500 500 500 500 Max. Turn-On Time ➃ 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle Max. Turn-Off Time 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle INP U T SPE C IFIC A TION S ➀ H12D48XXD Control Voltage Range 4-15Vdc Max. Turn-On Voltage 4.0 Vdc Min. Turn-Off Voltage 1.0 Vdc Nominal Input Impedance 240 Ohms Typical Input Current @ 5Vdc (@ 24Vdc for E-Suffix) 13mA G E N E R A L NO TES ➀ All parameters at 25˚C and per section unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 2. ➃ Turn-on time for random turn-on (-10) versions is 0.1 msec. Zero Voltage and R andom Turn-On Switching SCR Output Indu stry Standard Package Panel Mount FastFax Document No. 165 DUAL. Rev. 111203 PAGE 1 OF 2 Two totally independent AC output relays come in a single standard panel- mount package. Utilizing an AC switch output with internal snubber, relays provide greater protection against false triggering. Model choices include zero- voltage or random turn-on (phase con- trollable) switching. Manufactured in Crydom's ISO 9001 Certified facility for optimum product performance and reliability. C rydom H eat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom's Heat Sink specifica- tion sheet for all the details. © 2003 CRYDOM CORP, Specifications subject to change without notice. D2425D E D2440DE H12D4825D E H12D4840D E E -S U FF IX 15-32Vdc
15 Vdc
1.0 Vdc
1500 Ohms
4.0 Vdc
300 Ohms
For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Dual Relays 25-40A m p 120/240, 480 V ac A C O U TP U T
All dimensions are in inches (millimeters) C U RR E N T DE R A TING C U R V ES 120/240V MOD E L 480V MOD E L AVAI LA B LE OP TION S -10 Random Turn-On, Phase Controllable G E N E R A L SPE C IFIC A TION S Dielectric Strength50/60Hz Input/Output/Base 4000 Vrms Insulation Resistance (Min.) @ 500 Vdc 10 9 Ohm Max. Capacitance Input/Output 10 pF Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 1 25˚C M E C HANI C A L SPE C IFIC A TION S Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Thermally Conductive Epoxy Terminals: .25' Fastons, .025' Square Pins A PP R OVA LS UL E116949 CSA LR81689 (240V only) VDE 5902 UG FastFax Document No. 165 DUAL. Rev. 111203 PAGE 2 OF 2 ©2003 CRYDOM CORP, Specifications subject to change without notice. E 15-32Vdc Control Example: H12D4840D E 1.87 (47.5) .85 (21.6) 1.31 (33.2) 1.00 (25.4) 1.17 (29.7) FASTON TERMINAL .250 X .032 (4 PLACES) PIN .025 SQ. .100 CENTERS
4 PLACES
0.17 (4.3) DIA. ± 4-15VDC CONTROL BCONTROL A 4-15VDC ± CONTROL BCONTROL A A2 B1 120/24OV - 20A120/24OV - 20A .85 (21.6) 1.31 (33.2) .15 (3.8) .50 (12.7) .45 (11.4) .55 (14.0) 2.30 (58.4) 1.80 (45.7) .77 (19.6) 1.37 (34.8) 1.87 (47.5) 1.60 (40.6) MOUNTING HOLE/SLOT .017 (4.3) DIA.
2 PLC'S
120/24OV - 20A 120/24OV - 20A B1 B2 1.80 2.30 (58.4) -+ - + .250 X .032 FASTON TERMINAL (4 PLACES) .187 X .032 FASTON TERMINAL (4 PLACES) 2010 30 50 40 10 20 30 40 50 60 70 80 Load Current [Arms] Max Ambient Temp. [ ˚C] Max Allowable Base Temp. [˚C] Power Dissipation [W] 25A LIMIT (1 SECTION) 50A LIMIT (2 SECTIONS) 105 0.5˚C/W 1.0˚C/W2.0˚C/W 5.0˚C/W 240V Model B1 LOAD B 120/240Vrms 120/240Vrms -- B CONTROL + B CONTROL -- A CONTROL + A CONTROL LOAD A 100 4020 60 100 80 10 20 30 40 50 60 70 80 Load Current [Arms] Max Ambient Temp. [ ˚C] Max Allowable Base Temp. [˚C] Power Dissipation [W] 40A LIMIT (1 SECTION) 80A LIMIT (2 SECTIONS) 100 105 1.0˚C/W 2.0˚C/W 5.0˚C/W 0.5˚C/W 480V Model LOAD B B2A2A1 480Vrms 480Vrms + B CONTROL -- B CONTROL LOAD A -- A CONTROL + A CONTROL WI R ING DIAG R AM S 25A 40A Example: D2440D-10 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 H Heat Transfer Pad (Attached) Example: D2440DH Dual Relays 25-40A m p 120/240, 480 V ac A C O U TP U T