H12D SENSATA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 6

Technical content

Features

  • Ratings from 25A to 125A @ 48-530 VAC
  • Snubber Included
  • SCR output for heavy industrial loads
  • Zero Voltage or instantaneous turn-on outputs
  • UL/CSA/VDE Approved, CE Compliant to EN60950-1
  • Improved SEMS screw and washer
  • Redesigned housing with anti-rotation barriers
  • DC control
  • Direct bond copper substrate
  • EMC Compliant to Level 3
  • Direct power lead frame
  • Epoxy free design PRODUCT SELECTION Control Voltage 4-32 VDC 25A H12D4825 50A H12D4850 75A H12D4875 90A H12D4890 125A H12D48125 Note: Not all part number combinations are available. Contact Crydom Technical support for information on the availability of a specific part number. Serires Operating Voltage Transient Overvoltage 2D: 1200 Vpk Rated Load Current H1 2D 48 25 K P G H -10 ORDERING OPTIONS Required for valid part number For options only and not required for valid part number 48: 48-530 VAC 25: 25 Amps 90: 90 Amps 50: 50 Amps 125: 125 Amps 75: 75 Amps Termination Blank: Screw F: Quick Connect (Up to 50 Amps only) (1) K: Hex standoffs (2) Overvoltage Protection Blank: Not Included P: Included (3) Input Status LED Blank: Not Included G: Included Thermal Pad Blank: Not Included H: Included Switching Type Blank: Zero Voltage Turn-On -10: Instantaneous Turn-On (4) Page 1 www.sensata.comCopyright © 2018 Sensata Technologies, Inc.

OUTPUT SPECIFICATIONS (5) Description 125A90A75A50A25A Operating Voltage (47-63Hz) [Vrms] 48-530 48-530 48-530 48-530 48-530 Transient Overvoltage [Vpk] 1200 1200 1200 1200 1200 Maximum Off-State Leakage Current @ Rated Voltage [mArms] 10 10 10 10 10 Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] 500 500 500 500 500 Maximum Load Current [Arms] (6)(3) 25 50 75 90 125 Minimum Load Current [mArms] 150 150 150 150 150 Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 239/250 597/625 954/1000 1145/1200 1670/1750 Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec] 285/259 1770/1629 4555/4150 6560/5976 13950/12709 INPUT SPECIFICATIONS (5) Description DC Control Control Voltage Range 4-32 VDC Minimum Turn-On Voltage (7) 4.0 VDC Must Turn-Off Voltage 1 .0 VDC Maximum Reverse Voltage -32 VDC Minimum Input Current 7 mADC Maximum Input Current 12 mADC Nominal Input Impedance Current Regulated Maximum Turn-On Time [msec] (8) 1/2 Cycle Maximum Turn-Off Time [msec] 1/2 Cycle GENERAL SPECIFICATIONS(5) ParametersDescription Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms Minimum Insulation Resistance (@ 500 VDC) 109 Ohm Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range -40 to 80 °C Ambient Storage Temperature Range -40 to 125 °C Weight (typical) 2.6 oz (74.9 g) Housing Material UL94 V-0 Baseplate Material Aluminum Input Terminal Screw Torque Range (in-lb/Nm) 13-15 /1.5-1.7 Load Terminal Screw Torque Range (in-lb/Nm) 18-20 / 2.0-2.2 Input/Load Terminal Screw Torque Range (in-lb/Nm) (3) w/”K” option 8-10 / 0.9-1.13 SSR Mounting Screw Torque Range (in-lb/Nm) 18-20 / 2.0-2.2 Humidity per IEC60068-2-78 93% non-condensing LED Input Status Indicator w/”G” option (green) MTBF (Mean Time Between Failures) at 40°C ambient temperature (9) 11,641,553 hours (1,328 years) MTBF (Mean Time Between Failures) at 60°C ambient temperature (9) 7,210,376 hours (823 years) WIRING DIAGRAM S OLI D S T AT E R ELA Y OUTPUT INPUT Load (10) V 4 (–) 3 (+) 1 ( ) 2 ( ) AC Recommended Wire Sizes Terminals Wire Size (Solid / Stranded) Wire Pull-Out Strength (lb)[N] Input Output 24 AWG (0.2 mm 2) / 0.2 [minimum] 2 x 12 AWG (3.3 mm 2) / 3.3 [maximum] 20 AWG (0.5 mm 2) / 0.518 [minimum] 2 x 10 AWG (5.3 mm 2) / 5.3 2 x 8 AWG (8.4 mm 2) / 8.4 [maximum] 10 [44.5] 90 [400] 30 [133] 110 [490] 90 [400] Input Current vs Input Voltage Standard Regulated DC Input Input Current (mA) 0 5 10 15 20 25 30 DC Input Voltage Input/Output Terminal Screw Thread Size #6-32 UNC / #8-32 UNC Page 2 www.sensata.comCopyright © 2018 Sensata Technologies, Inc.

MECHANICAL SPECIFICATIONS(5) Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] Screw Termination

1 OUTPUT 2

4 INPUT 3

1.1 [27.9] 0.49 [12.4] Mounting Hole/Slot 0.19 [4.9] DIA. 0.89 [22.6] 1.88 [47.6] 1.7 [43.2] 2.25 [57.3] 1.0 [25.4] 1.75 [44.5] Hex Standoff Termination (“K” Option) 1.1 [27.9] 0.49 [12.4] Mounting Hole/Slot 0.19 [4.9] DIA. 1.04 [26.4] 1.88 [47.6] 1.70 [43.2] 2.25 [57.3] 1.0 [25.4] 1.75 [44.5] 0.93 [23.6] (4 places) 1.0 [25.4] (2 places) (3) Quick Connect Termination (“F” Option) - Up to 25 Amp (2) 0.19 [4.9] DIA. 1.58 [40.2] 0.49 [12.4] Faston Terminal(13) 0.25 x 0.032 (2 places) 1.31 [33.4] 1.88 [47.6] 1.7 [43.2] 2.25 [57.3] 1.40 [35.6] 1.75 [44.5] Faston Terminal(13) 0.187 x 0.020 (2 places) 1.25 [31.8] Quick Connect Termination (“F” Option) - Up to 50 Amp (2) S OLI D S T AT E R ELA Y OUTPUT INPUT Mounting Hole/Slot 0.19 [4.9] DIA. 1.58 [40.2] 0.49 [12.4] Faston Terminal(13) 0.25 x 0.032 (4 places) 1.31 [33.4] 1.88 [47.6] 1.7 [43.2] 2.25 [57.3] 1.40 [35.6] 1.75 [44.5] Faston Terminal(13) 0.187 x 0.020 (2 places) 1.25 [31.8] 0.63 [16.0] 0.45 [11.4] (2 places) +DC -DC AC Trigger Circuit Current Limiter AC (11) (12) EQUIVALENT CIRCUIT BLOCK DIAGRAMS Page 3 www.sensata.comCopyright © 2018 Sensata Technologies, Inc.

0.01 0.1 1 10 Surge Current (Amp) Surge Duration (Secs) 25 A 100 200 300 400 500 600 0.01 0.1 1 10 Surge Current (Amp) Surge Duration (Secs) 50 A 100 200 400 300 500 600 700 900 800 0.01 0.1 1 10 Surge Current (Amp) Surge Duration (Secs) 75 A 150 450 300 600 750 900 1200 1050 0.01 0.1 1 10 Surge Current (Amp) Surge Duration (Secs) 90 A 200 400 800 600 1000 1200 1400 1800 1600 0.01 0.1 1 10 Surge Current (Amp) Surge Duration (Secs) 125 A Non repetitive peak surge current at Tj initial 40ºC. THERMAL DERATE INFORMATION 20 30 40 50 60 70 80 Ambient Temperature (ºC) Load Current (Amps) 25 A 1.5ºC/W 2ºC/W 3ºC/W 20 30 40 50 60 70 80 Ambient Temperature (ºC) Load Current (Amps) 50 A 0.7ºC/W 1ºC/W 1.5ºC/W 2ºC/W 20 30 40 50 60 70 80 Ambient Temperature (ºC) Load Current (Amps) 75 A 0.5ºC/W 0.7ºC/W 1ºC/W 1.5ºC/W 20 30 40 50 60 70 80 Ambient Temperature (ºC) Load Current (Amps) 90 A 0.5ºC/W 0.7ºC/W 1ºC/W 1.5ºC/W 100 120 20 30 40 50 60 70 80 Ambient Temperature (ºC) Load Current (Amps) 125 A 0.5ºC/W 0.7ºC/W 1ºC/W Page 4 www.sensata.comCopyright © 2018 Sensata Technologies, Inc.

Designed in accordance with the requirements of IEC 62314 IEC61000-4-2 : Electrostatic Discharge – Level 3 IEC61000-4-4 : Electrically Fast Transients – Level 3 IEC61000-4-5 : Electrical Surges – Level 3 IEC 60068-2-6 : Vibration 0.35mm and 0.75mm Amplitude over 10-55 Hz IEC 60068-2-27 : Shock Resistance 15g/11ms

10143 UG LR81689

E116949 (25, 50, 75 and 90A) E116950 (125A) Part number: KS101 Clear plastic cover compatible with all new S1 designs. Safety covers provide added protection from electric shock when installing or checking equipment. Protective Cover Hardware Kit Part number: HK4 Bag with 2 square brass accessories and 2 screw 8-32 x 5/8 for output. Used to mount TMR1 lug terminals. Protective Cover & Hardware Kits Recommended Accessories Cover Hardware Kit Heat Sink Part No. Thermal Resistance [ºC/W] Lug Terminal Thermal Pad KS101 HK1 HK4 TRM1 TRM6 HSP-1 HSP-2 HS501DR HS301 / HS301DR HS251 HS202 / HS202DR HS201 / HS201DR HS172 HS151 / HS151DR HS122 / HS122DR HS103 / HS103DR HS101 HS073 HS072 HS053 HS033 HS023 5.0 3.0 2.5 2.0 2.0 1.7 1.5 1.2 1.0 1.0 0.7 0.7 0.5 0.36 0.25 ACCESORIES Page 5 GENERAL NOTES For additional information or specific questions, contact Crydom Technical Support. (1) Single pair (up to 25A) Double pair* (50A model only). *Caution: User must connect to both pairs For higher load currents, the “K” standoff temperature must not exceed 105°C. For additional application assistance please contact Crydom Technical Support. (3) Output will self trigger between 900-1200Vpk, Min. power factor 0.7 or higher, not suitable for capacitive loads. (4) Instantaneous turn-on version is not recomended for capacitive loads. Use zero turn-on only. (5) All parameters at 25°C unless otherwise specified. (6) Heat sinking required, see derating curves. (7) Increase minimum voltage by 1V for operations from -20 to -40°C. (8) Turn-on time for Instantaneous turn-on versions is 0.02 msec. (9) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report). (10) Load can be wired to either SSR output terminal 1 or 2. (11) Elective Input Status LED, “G” option. (12) Elective Overvoltage Protection, “P” option. (13) Mechanical dimensions vary from G3 models. www.sensata.comCopyright © 2018 Sensata Technologies, Inc.

RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE

  • The product’s side panels may be hot, allow the product to cool before touching
  • Follow proper mounting instructions including torque values
  • Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
  • Disconnect all power before installing or working with this equipment
  • Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury CONTACT USSensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. www.sensata.comCopyright © 2018 Sensata Technologies, Inc. Americas +1 (877) 502 5500 – Option 2 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Rev. 021218 ECN 20395 FDE-07-01 Rev. B