Product: H126T00 H126T00 - Broadband Coax, H126T, 18 AWG Solid BC, Tri-shield, PVC Jkt Product Description Broadband Coax, H126T, 18 AWG Solid Bare Copper Conductor, PE Insulation, Duofoil + 60% Tinned Copper Braid + Foil Shield, PVC Jacket Technical Specifications Product Overview Suitable Applications: Broadband, Cable Television (CATV), RF drop cable, Over-The-Air (OTA) antennas Construction Details RG Type: 6 Conductor No. of Elements Size Stranding Nom. Diameter Material 1 18 AWG Solid 1 mm BC - Bare Copper Insulation Material Nom. Insulation Diameter PE - Polyethylene (Foam) 4.57 mm (0.180 in) Outer Shield Layer Outer Shield Type Material Coverage
1 Tape Tri-Laminate (Alum+Poly+Alum) 100%
2 Braid Tinned Copper (TC) 60%
3 Tape Bi-Laminate (Alum+Poly) 100%
Material Nom. Diameter PVC - Polyvinyl Chloride 6.9 mm Table Notes: According to EN 50290-2-20
Electrical Characteristics
Regularity of Impedance: Min. 40 dB Return Loss (RL) Frequency Min. Return Loss 5 - 470 MHz 20 dB 470 - 1000 MHz 18 dB 1000 - 2000 MHz 16 dB 2000 - 3000 MHz 15 dB Table Notes: In each frequency band, 3 peak values up to 4 dB lower are allowed Attenuation Frequency Nom. Attenuation 5 MHz 1.8 dB/100m 50 MHz 4.7 dB/100m 100 MHz 6.5 dB/100m
230 MHz 9.8 dB/100m
400 MHz 13 dB/100m
800 MHz 18.7 dB/100m 862 MHz 19.5 dB/100m 1000 MHz 21.1 dB/100m 1350 MHz 24.9 dB/100m 1750 MHz 28.8 dB/100m 2150 MHz 32.3 dB/100m 2400 MHz 34.4 dB/100m 3000 MHz 39.2 dB/100m Table Notes: Max. attenuation 10% higher Electricals 23 Ohm/km (7.0 Ohm/1000ft) 12 Ohm/km (3.7 Ohm/1000ft) 54 pF/m (16 pF/ft) 75 Ohm 82% Transfer Impedance Max. Transfer Impedance Max. 2.5 mOhm/m Screening Frequency Min. Screening Attenuation 30 - 1000 MHz 95 dB 1000 - 2000 MHz 85 dB 2000 - 3000 MHz 75 dB Screening Class: A+ Mechanical Characteristics Temperature Operating Installation Storage -40°C To +70°C -5°C To +50°C -40°C To +70°C Bend Radius Stationary Min. 65 mm (2.6 in) Bulk Cable Weight: 51 kg/km Standards and Compliance Environmental Suitability: Indoor - Euroclass Eca Flammability / Reaction to Fire: IEC 60332-1-2 CPR Compliance: CPR Euroclass: Eca CENELEC Compliance: EN 50117-1 UK Regulation Compliance: UKCA Mark History Update and Revision: Revision Number: 0.215 Revision Date: 02-05-2024 Part Numbers Variants Item # Color Putup Type Length EAN H126T00.01B100 White Flat Box 100 m 8719605087621 H126T00.01500 White Reel 500 m 8719605087614 © 2024 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.