H0505D-2W MORNSUN | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

The copyright and authority for the interpretation of the products are reserved by Mornsun Specifications subject to change without notice. G_D-2W & H_D-2W A/3-2008 Page 1 of 2 G_D-2W & H_D-2W Series 2W, FIXED INPUT, 6000V ISOLATED & UNREGULATED DUAL/SINGLE OUTPUT DC-DC CONVERTER multi-country patent protection RoHS PRODUCT PROGRAM Input Output Voltage (VDC) Current (mA) Part Number Nominal Range Voltage (VDC) Max Min Efficiency (%, Typ) Certificate H0505D-2W 5 400 40 75 UL H0509D-2W 9 222 23 76 UL H0512D-2W 12 167 17 78 UL H0515D-2W 15 133 13 77 UL G0505D-2W ±5 ±200 ±20 75 UL G0509D-2W ±9 ±111 ±12 77 UL G0512D-2W ±12 ±84 ±9 79 UL G0515D-2W 5 4.5-5.5 ±15 ±67 ±7 78 UL H1205D-2W 5 400 40 75 UL H1209D-2W 9 222 23 78 UL H1212D-2W 12 167 17 80 UL H1215D-2W 15 133 14 78 UL G1205D-2W ±5 ±200 ±20 76 UL G1209D-2W ±9 ±111 ±12 78 UL G1212D-2W ±12 ±84 ±9 80 UL G1215D-2W 12 10.8-13. ±15 ±67 ±7 78 UL H2405D-2W 5 400 40 77 H2409D-2W 9 222 23 78 H2412D-2W 12 167 17 81 H2415D-2W* 15 133 14 80 G2405D-2W* ±5 ±200 ±20 77 G2409D-2W* ±9 ±111 ±12 78 G2412D-2W* ±12 ±84 ±9 81 G2415D-2W* 24 21.6-26.4 ±15 ±67 ±7 80 *Designing. Note: The G_D-1W/H_D-1W series also are available in our company. ISOLATION SPECIFICATIONS Item Test Conditions Min Typ Max Units Isolation voltage Tested for 1 minute and 1mA max 6000 VDC Isolation resistance Test at 500VDC 1000 M Ω Isolation capacitance 3.5 pF COMMON SPECIFICATIONS Item Test Conditions Min Typ Max Units Storage humidity 95 % Operating temperature -40 85 Storage temperature -55 125 Temp. rise at full load 15 30 Lead temperature 1.5mm from case for 10 seconds 300 Short circuit protection Continuous Cooling Free air convection Case material Plastic(UL94-V0) MTBF 3500 K hours

FEATURES

High Efficiency up to 81% 6KVDC Isolation Low Isolation capacitance Temperature Range -40°C to +85°C No Heat Sink Require Internal SMD Construction No External Component Required Continuous short circuit protection Industry Standard Pinout RoHS Compliance

APPLICATIONS

The G_D-2W & H_D-2W Series are specially designed for applications where a group of polar power supplies are isolated from the input power supply in a distributed power supply system on a circuit board. These products apply to: 1) Where the voltage of the input power supply is fixed (voltage variation ≤±10%); 2) Where isolation is necessary between input and output (isolation voltage ≤6000VDC); 3) Where the regulation of the output voltage and the output ripple noise are not demanded. Such as: purely digital circuits, ordinary low frequency analog circuits, and IGBT power device driving circuits. MODEL SELECTION G0505D-2W RatedPower Package Style Output Voltage Input Voltage Product Series MORNSUN Science & Technology co.,Ltd. Address:2th floor 6th building, Hangzhou Industrial District, Guangzhou, China Tel: 86-20-38601850 Fax: 86-20-38601272 http://www.mornsun-power.com Weight 8.2 g

The copyright and authority for the interpretation of the products are reserved by Mornsun Specifications subject to change without notice. G_D-2W & H_D-2W A/3-2008 Page 2 of 2 OUTPUT SPECIFICATIONS Item Test conditions Min Typ Max Units Output power 0.2 2 W Line regulation For Vin change of 1% ±1.2 5V output 10 15 9V output 8.3 15 12V output 6.8 15 Load regulation 10% to 100% load 15V output 6.3 15 Output voltage accuracy See tolerance envelope graph Temperature drift 100% full load 0.03 %/°C Ripple & Noise* 20MHz Bandwidth 150 250 mVp-p 5V input 35 Switching frequency Full load, nominal input 12V,24V input 50 KHz *Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power Converter section, application notes. Note: Dual output models unbalanced load: ±5%. TYPICAL CHARACTERISTICS Ambient Temperature C ( ) OUTLINE DIMENSIONS & PIN CONNECTIONS 1213, Vin GND NC +Vo Vin GND -Vo +Vo Others NCNC Note: Unit:mm(inch) Pin section:0.50*0.30mm(0.020*0.012inch) Pin section tolerances:0.10mm(0.004inch) General tolerances:0.25mm(0.010inch) Pin Single Dual First Angle Projection RECOMMENDED FOOTPRINT Top view,grid:2.54mm(0.1inch) diameter:1.00mm(0.039inch) 141716 13 89 11 FOOTPRINT DETAILS NC: No connection Single/Dual Ouput ( ) SideView ( ) BottomView 16.65(0.656) (0.409) 10.40 0.50 (0.020) 4.90 (0.193) 10.30 (0.406) 32.30(1.272) 16.65(0.656) 14.40(0.560) 2.54(0.100) 27.94(1.100) 12 89 11 1417 161315 APPLICATION NOTE Requirement on output load To ensure this module can operate efficiently and reliably, During operation, the minimum output load is not less than 10% of the full load, and that this product should never be operated under no load! If the actual output power is very sm all, please connect a resistor with proper resistance at the output end in parallel to increase the load, or use our company’s products with a lower rated output power(G/H_D-1W Series) Recommended testing and application circuit If you want to further decrease the input/output ripple, an “LC” filtering network may be connected to the input and output ends of the DC/DC converter, see (Figure 1). Vin GND +Vo 0VDCCin L L DC L Cout Cout -Vo Dual Output L Single Output Vin GND +Vo DCCin L DC Cout (Figure 1) It should also be noted that th e inductance and the frequency of the “LC” filtering network should be staggered with the DC/DC frequency to avoid mutual interference . However, the capacitance of the output filter capacitor must be proper. If the capacitance is too big, a startup problem might arise. For every channel of output, provided the safe and reliable operation is ensured, the greatest capacitance of its filter capacitor sees (Table 1). EXTERNAL CAPACITOR TABLE (Table 1) Vin (VDC) Cin (uF) Single Vout (VDC) Cout (uF) Dual Vout (VDC) Cout (uF) 5 4.7 5 10 ±5 4.7 12 2.2 9 4.7 ±9 2.2 24 1 12 2.2 ±12 1 - - 15 1 ±15 1 It’s not recommended to connect any external capacitor in the application field with less than 0.5 watt output. Output Voltage Regulation and Over- voltage Protection Circuit The simplest device for output voltage regulation, over-voltage and over- current protection is a linear voltage regulator with overheat protection that is connected to the input or output end in series (Figure 2). Vin GND +Vo DCDC -Vo REG REG REG Dual Output Single Output Vin GND +Vo DC DC REG REG (Figure 2) Overload Protection Under normal operating conditions, the output circuit of these products has no protection against overload. The simplest method is to connect a self-recovery fuse in series at the input end or add a circuit breaker to the circuit. No parallel connection or plug and play. Note: 1. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified. 2. Only typical models listed , other models may be different, plea se contact our technical person for more details. 3. Operation under minimum load will not damage the converter; However, they may not meet all specification listed.