DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
Gas Discharge Tubes Document: SCD27380 © 2008, 2011 Tyco Electronics Corporation. S tatus: Released a TE Connectivity Ltd. Company. All rights reserved. Rev: C Date: MAY 18, 2 011 Benefits: Compact, small form factor suitable for efficient assembly Helps provide overvoltage fault protection against high energy surges Suitable for highqfrequency applications Features: 3Pole, 6mm devices Broad voltage range from 75Vq600V Various form factors: surfaceqmount, leaded, no leads Optional failqshort mechanism on some devices Low capacitance and insertion loss Crowbar overvoltage protection UL 497B recognized RoHS compliant Devices tested per ITU K.12 recommendations Nonqradioactive materials Applications: Telecommunications • Industrial and consumer electronics, such as q MDF modules, xDSL equipment, RF system q Surge protectors protection, antenna, base station q Alarm system TE Circuit Protection 6mm 3Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal lines and data transmission lines from damage caused by transient surge voltages that typi cally result from lightning strikes and equipment switching operations. TE Circuit Protection GDTs offer a high level of surge protection, low capacitance and a broad array of breakover voltage levels , making them suitable for applications such as MDF (Ma in Distribution Frame) modules, high data1 rate telecom applications (e.g. ADSL, VDSL), and surge protection on power lines. Raychem Circuit Protection GDTs can help equipment meet the most stringent regulatory standards.
Gas Discharge Tubes Document: SCD27380 © 2008, 2011 Tyco Electronics Corporation. S tatus: Released a TE Connectivity Ltd. Company. All rights reserved. Rev: C Date: MAY 18, 2 011 GTCX36-XXXM-R10 Series Device Voltage Ratings and Part Marking Device Surge Rating, Capacitance, Insulation Resistance, UL Part Number DC Sparkover Impulse Sparkover DC Holdover Voltage On-State Voltage @100V/s ±20% Tolerance (V) @100 Vµs (V) @1000 Vµs (V) Per ITU K.12 (<150ms) (V) Nominal (@ 1A) (V) GTCX36q750MqR10 75 450 550 <52 20 GTCX36q900MqR10 90 450 550 <52 20 GTCX36q141MqR10 140 500 600 <80 20 GTCX36q151MqR10 150 500 600 <80 20 GTCX36q201MqR10 200 600 700 <135 20 GTCX36q231MqR10 230 600 700 <135 20 GTCX36q251MqR10 250 600 700 <135 20 GTCX36q261MqR10 260 700 800 <135 20 GTCX36q301MqR10 300 800 900 <150 20 GTCX36q351MqR10 350 900 1000 <150 20 GTCX36q401MqR10 400 900 1000 <150 20 GTCX36q421MqR10 420 900 1000 <150 20 GTCX36q471MqR10 470 1050 1150 <150 20 GTCX36q501MqR10 500 1100 1200 <150 20 GTCX36q551MqR10 550 1300 1400 <150 20 GTCX36q601MqR10 600 1300 1400 <150 20 Part Number Impulse Discharge Current Impulse Life AC Discharge Current (1sec duration; 10 hits) Capacitance Insulation Resistance UL Rating 8x20µs 10 hits 10x1000µs 300 hits @50 Hz @1Mhz @100V* UL497B #E179610 GTCX36qXXXMqR10 10kA 200A 10Arms <1pF 10,000 (MΩ) All Devices * Devices <=150V measured @ 50V. Devices >= 500V measured @ 250V
Gas Discharge Tubes Document: SCD27380 © 2008, 2011 Tyco Electronics Corporation. S tatus: Released a TE Connectivity Ltd. Company. All rights reserved. Rev: C Date: MAY 18, 2 011 GTCX36-XXXM-R10 Series Product Dimensions DIMENSIONS = MILLIMETERS [INCHES] Axial Leaded with - FT (GTC A3 6-XXX M-R10 -FT ) Axial Leaded ( GTCA3 6-XXX M-R10 ) Radial Leaded with - FT ( GTC R3 6-XXX M-R10 -FT ) Radial Leaded (GTC R3 6-XXX M-R10 )
Gas Discharge Tubes Document: SCD27380 © 2008, 2011 Tyco Electronics Corporation. S tatus: Released a TE Connectivity Ltd. Company. All rights reserved. Rev: C Date: MAY 18, 2 011 GTCX36-XXXM-R10 Series Pad Layout – Surface -mount Devices (GTCS36 -XXXM -R10) No Lead s with - FT (GTC N3 6-XXX M-R10 -FT ) No Lead s (GTC N36 -XXXM -R10) Surf ace -mount (GTC S3 6-XXX M-R10) X Y1 Y2 Z1 Z2 NOM NOM NOM NOM NOM
Gas Discharge Tubes Document: SCD27380 © 2008, 2011 Tyco Electronics Corporation. S tatus: Released a TE Connectivity Ltd. Company. All rights reserved. Rev: C Date: MAY 18, 2 011 GTCX36-XXXM-R10 Series General Characte ristics Packaging Information Part Numbering System Mater ials Information RoHS Compliant ELV Compliant No Radioactive Material Storage Temperature: q40ºC to +90ºC Operating Temperature: q40ºC to +90ºC Body: Nickel Plated Leads: Surfaceqmount, Radial and Axial Devices: Tin Plated Devices with no leads: Nickel Plated Soldering Notes: Devices with no leads: non-solderable; suitable for insertion into a magazine clip Part Description Tray / Reel Standard Package No Leaded: GTCN36qXXXMqR10 100pcs (Tray) 2,500 pcs With Leads: GTCA36qXXXMqR10/GTCR36qXXXMqR10 10 0pcs (Tray) 1,000pcs Surfaceqmount: GTCS36qXXXMqR10 100pcs (Tray) 2,500p cs Surfaceqmount (T&R): GTCS36qXXXMqR10q2 750pcs 6000p cs Example Part Number: GTCX3 6-351M -R10 -FT GT = Gas Tube C = Ceramic X = Lead Configuration: N= No leads; A= Axial Leads; S= Surfaceqmount; R= Radial Leads 3 = 3 Electrode device 6 = 6mm Diameter 351 = DC Spark Over Voltage of 350V (at 100V/s) M = Tolerance of 20% on DC Spark Over Voltage R = Product Family Designator 10 = Surge rating: 8x20µs 10kA 10 times FT = With FailqShort mechanism
Gas Discharge Tubes Document: SCD27380 © 2008, 2011 Tyco Electronics Corporation. S tatus: Released a TE Connectivity Ltd. Company. All rights reserved. Rev: C Date: MAY 18, 2 011 GTCX36-XXXM-R10 Series Part Marking Reference 308 Constitution Drive, MS R21/2A Tel (800) 227-7040 www.circuitprotection.com Menlo Park, CA USA 94025-1164 (650) 361-6 900 www.circuitprotection.com.hk (Chinese) FAX (650) 361-2508 www.circuitprotection.jp (Japanese) TE Connectivity, TE Connectivity (Logo) and TE (Logo) are trademarks. Information furnished is believed to be accurate an d reliable. However, users should independently ev aluate the suitability of and test each product selected for their own applications. Tyco Electronics Corporation and/or its Affiliates in the TE Con nectivity Ltd. family of companies (‘TE”) reserves the right to change or update, without notice, any information contained in this publication; to change, without notice, the design, construction, processing, or specification of any product; and to discontinue or limit production or distribution of any product. This publication supersedes and replaces all information previously supplied. Without expressed or written consent by an officer of TE, TE does no t authorize the use of any of its products as components in nuclear facility applications, aerosp ace, or in critical life support devices or systems . TE expressly disclaims all implied warranties regarding the information contained herein, includi ng, but not limited to, any implied warranties of m erchantability or fitness for a particular purpose. TE only obligations are those in the TE Standard Terms and Conditions of Sale and in no case will TE be l iable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of its products. Example Part Marking: 35 R10 GN = Manufacture Mark 35 = Voltage Designator (35 = 350V) R10 = Product Family Designator + Surge Current 10k A (8x20µs 10 hits) GN = Year and Week of Manufacture