308 Constitution Drive
Menlo Park, CA 94025-1164 Phone: 800-227-4856 www.circuitprotection.com Gas Discharge Tube High Surge Two Electrode Series Overvoltage Protection Device Raychem Circuit Protection Products PRODUCT: GTCx28-xxxx-P15 DOCUMENT: SCD 25820 REV LETTER: C REV DATE: MAY 25, 2007 PAGE NO.: 1 OF 5 Specification Status: Released SYMBOL TYPICAL APPLICATION SCHEMATIC BENEFITS
- Helps provide overvoltage fault protection against high energy surges
- Suitable for sensitive equipment due to excellent impulse sparkover response
- Suitable for high-frequency applications
- Highly reliable performance
FEATURES
- Crowbar device with low arc-voltage
- Low capacitance and insertion loss
- High accuracy spark-over voltages for high precision designs
- Tested per ITU K.12 recommendations
- Optional Fail-Short mechanism
- Non-radioactive materials
APPLICATIONS
- Telecommunications: - MDF modules, xDSL equipment, RF system protection
- Industrial Electronics and Commercial Electronics, such as - Power Supplies, Surge Protectors, Alarm systems SiBar Device PolySwitch Device
Menlo Park, CA 94025-1164 Phone: 800-227-4856 www.circuitprotection.com Gas Discharge Tube High Surge Two Electrode Series Overvoltage Protection Device Raychem Circuit Protection Products PRODUCT: GTCx28-xxxx-P15 DOCUMENT: SCD 25820 REV LETTER: C REV DATE: MAY 25, 2007 PAGE NO.: 2 OF 5 PART NUMBERING EXAMPLE: DEVICE MARKING EXAMPLE : GTCN28-900M-P15 GT C N 2 8 - 231 M -P 15 -F S Series Packaging GT : Gas Tube No Suffix: standard Tray packaging -B: Bulk packaging (only upon special request) Material C : Ceramic with Fail-Short mechanism Type Surge Rating N : No Leads 15 : 15kA (10 times 8 x 20 μs) A : Axial Leaded Product Family Number of Electrodes 2 : Two Voltage Tolerance M : ± 20% Diameter 8 : 8mm Voltage Designator 900 : 90 x 10^0 = 90V 151 : 15 x 10^1 = 150V 231 : 23 x 10^1 = 230V 251 : 25 x 10^1 = 250V 351 : 35 x 10^1 = 350V
09 P 15 GN
Per Raychem Circuit Protection lot number system : E.g. G = First half of 2004; N = week 14 Surge Rating: 15 : 15kA Product Family Voltage Designator 09 : 90 V Raychem Symbol
Menlo Park, CA 94025-1164 Phone: 800-227-4856 www.circuitprotection.com Gas Discharge Tube High Surge Two Electrode Series Overvoltage Protection Device Raychem Circuit Protection Products PRODUCT: GTCx28-xxxx-P15 DOCUMENT: SCD 25820 REV LETTER: C REV DATE: MAY 25, 2007 PAGE NO.: 3 OF 5 GENERAL CHARACTERISTICS No Radioactive Material Storage temperature: Devices without Fail-Short Mechanism: -40°C … +90°C Devices with Fail-Short Mechanism: -20°C … +65°C Operating temperature: Devices without Fail-Short Mechanism: -40°C … +90°C Devices with Fail-Short Mechanism: -20°C … +65°C Body: Nickel Plated Leads: Tin Plated DEVICE RATINGS AND CHARACTERISTICS DC Sparkover Voltage Impulse Sparkover Voltage Insulation Resistance Capacitance DC Holdover Voltage Impulse Life Impulse Discharge Current 8/20μs AC Discharge Current, 50Hz Part Number @ 100V/s @ 100V/μs @ 1kV/ μs @ 100V DC @ 1MHz Per ITUK.12 10/1000μs, 100A Single Hit Repeat 10 times (5 times each polarity) Single Hit, 9 Cycles Repeat 10 times (1s interval) GTCN28-900M-P15 GTCA28-900M-P15 72 - 108V ≤ 450V ≤ 500V ≥ 10,000MΩ ≤ 1.5pF ≤ 52V 300 times 20kA 15kA 90A 20A GTCN28-151M-P15 GTCA28-151M-P15 120 - 180V ≤ 500V ≤ 600V ≥ 10,000MΩ ≤ 1.5pF ≤ 52V 300 times 20kA 15kA 90A 20A GTCN28-231M-P15 GTCN28-231M-P15-FS GTCA28-231M-P15 184 -280V ≤ 600V ≤ 700V ≥ 10,000MΩ ≤ 1.5pF ≤ 3.5pF ≤ 1.5pF ≤ 52V 300 times 20kA 15kA 90A 20A GTCN28-251M-P15 GTCA28-251M-P15 200 - 300V ≤ 600V ≤ 700V ≥ 10,000MΩ ≤ 1.5pF ≤ 52V 300 times 20kA 15kA 90A 20A GTCN28-351M-P15 GTCA28-351M-P15 280 - 420V ≤ 700V ≤ 800V ≥ 10,000MΩ ≤ 1.5pF ≤ 52V 300 times 20kA 15kA 90A 20A Note 1. Insulation Resistance measured at 50 VDC.
Menlo Park, CA 94025-1164 Phone: 800-227-4856 www.circuitprotection.com Gas Discharge Tube High Surge Two Electrode Series Overvoltage Protection Device Raychem Circuit Protection Products PRODUCT: GTCx28-xxxx-P15 DOCUMENT: SCD 25820 REV LETTER: C REV DATE: MAY 25, 2007 PAGE NO.: 4 OF 5 DIMENSIONS No Leads, no Fail-Short mechanism (GTCN28-xxxx-P15) *Rounded off approximation No Leads, with Fail-Short mechanism (GTCN28-231M-P15-FS) Fail-Short Operation Time 50Hz 0.7A : 210s 2.0A : 60s 7.0A: <1s *Rounded off approximation Axial Leads, no Fail-Short mechanism (GTCA28-xxxx-P15) *Rounded off approximation A C MIN MAX MIN MAX in*: 0.23 0.24 0.31 0.32 A B C F G MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX A C D ∅d MIN MAX MIN MAX MIN MAX NOM
Menlo Park, CA 94025-1164 Phone: 800-227-4856 www.circuitprotection.com Gas Discharge Tube High Surge Two Electrode Series Overvoltage Protection Device Raychem Circuit Protection Products PRODUCT: GTCx28-xxxx-P15 DOCUMENT: SCD 25820 REV LETTER: C REV DATE: MAY 25, 2007 PAGE NO.: 5 OF 5 PACKAGING Packaging Bulk* ( vacuum bags) Tray Standard Box Quantity 200 100 1,000** * Standard packaging is in trays. Bulk packaging is only available upon request. ** 5 bags or 10 trays Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of each product for their applications. Tyco Electronics Corporation assume s no responsibility for the use of its product or for any in fringement of patents or other rights of third parties resulting from the us e of its product. No license is granted by implication or oth erwise under any patent or proprietary right of Tyco Electronics except the ri ght to use such product for the purpose for which it is sold. Ty co Electronics reserves the right to change or update, without notic e, any information contained in this publication; to change, w ithout notice, the design, construction, processing, or specification of any product; and to discontinue or limit production or distribution of any product. This publication supersedes and replaces all information previously supplied. Without expressed or written consent b y an officer of Tyco Electronics, Tyco Electronics does not authorize the use of any of its products as components in nuclear facili ty applications, aerospace, or in critical life support devices or systems. Tyco Electronics’ only obligations are those in the T yco Electronics Standard Terms and Conditions of Sale and in no ca se will Tyco Electronics be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of its products. © 2004, 2007 Tyco Electronics Corporation. All rights reserved.