GT12-55AG ETC | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Application · Electric Powered Toys
- Control System· Broadband
- Vacuum Cleaners· Electric Powered Vehicles
- Medical Equipments· UPS
- Golf Cars and Buggies· Photovoltaic & Solar System
- Wheel Chairs General Features
- Ideal for cyclic uses
- Good tolerance to higher temperature applications.
- ABS containers and covers(UL94HB, UL94V-0) optional.
- Safety valve installation for explosion proof.
- Higher safety & reliable construction.
- Extra durability and deep cycle ability for heavy demand applications.
- Low self discharge characteristic.
- Good tolerance to higher temperature applications. Construction thixotropic Gel 229mm(9.02inch) 138mm(5.44inch) m m 8.3inch) 228 m 898inch) m 13.2mm(0.52inch) 18mm(0.71inch) 9.9mm(0.39inch) 19mm(0.75inch) 7.8mm(0.31inch) GT12-55AG 20HR(2.75A,1.75V) 55AH Length 230mm(9.04inch) 10HR(5.4A,1.75V) 54AH Width 138mm(5.44inch) 5HR(9A,1.75V) 45AH Height 209mm(8.23inch) 1HR(33A,1.75V) 33AH Total Height 228mm(8.98inch) o Full charged at 25 C: 0.006 Ohm o 3% of capacity declined per month at (25 C) 102% 100% 85% 65% Cycle use Float use o o
40 C o
25 C o
-15 C 17Kg (37.5 lbs) Battery Model o Capacity(25C) Dimensions Approx. Weight Internal Resistance Self Discharge Capacity Affected by Temp.(20HR) o Charge Voltage(25C) o 14.4-15V(-30mV/ C), max. Current: 13.75A 10 Years (Floating) or > 750 Cycles @ 50% D.O.DDesigned Life GT12-55AG12V55AH/C20 -AG RangeGT -AG RangeGT AGM and Gel Range batteries uses the advanced GEL design which combines the best features of AGM and GEL construction into one battery line, and the purity fumed silica to form sulfuric acid thixotropic Gel and fills to the batteries with vacuum to ensure the fully penetration of electrolyte through seperators and plates pastes. This range battery are designed to meet the requir ement of frequent cyclic and high temperature application such as boardband, PVs etc. Standard Terminal Dimensions(Optional terminal please check terminal information page)
o Constant current discharge ratings-amperes at 25 C o Constant power discharge ratings-watts at 25 C 0.25 0.10 20 0.05 0.15 0.20 0 2 100 120 (CA) (V/Cell) 84 6 10 12 Charge Characteristic Charge Capacity Charge Voltage 100%Discharge Charge Current Time(hour) 2.33 2.17 2.00 1.83 Charge Capacity Charge Current Charge Voltage 50%Discharge (%) o Constant Charge At 13.75A-13.80V (25 C) Page 2 of 2 Discharge Voltage (V) 13.0 12.0 11.0 10.0 9.00 8.00 0 2 6 12 30 60 3 10 20 Min Hour 275A 110A 55A 33.0A 13.75A 0.55A 2.75A o Discharge Characteristic (25 C) F.V /Time 5MIN 10M IN 15M IN 30M IN 1HR 3HR 5HR 10H R 20H R F.V /Time 5MIN 10M IN 15M IN 30M IN 1HR 3HR 5HR 10H R 20H R 300 900600 1200 1500 1800 100 120 Number of Cycles 100%D.O.D 50%D.O.D 30%DEPTH OF DISCHARGE CAPACITY(%) Cycle service life Storage time: months 20191817161514131211109876543210 Capacity (%) 100 105 110 Self Discharge Characteristics o
30 C o
AMBIENT TEMPERATURE:o
20 TO 25 Co
68 TO 77 F
-AG RangeGT -AG RangeGT