Features
Cost efficient termination Highly efficient and reliable single motion crimp termination allows high volume production with semi- automatic equipment. Lock-release latching system Shock / vibration resistant electrical connections Verification of the full contact insertion Excellent shielding effects. Excellent High Frequency Performance Termination of coaxial cables in automotive, medical and instrumentation applications utilizes a single motion to crimp the center conductor, shield and outer Insulator.
BDiagram of GT1 In-line Type Structure High Frequency Characteristics (V.S.W.R.) Note: Data taken using fully assemblied and connected GT1-1S-HU and GT1-1P-DSA. Part Number Part Number Used Material Finish
1 GT1-1P-HU Housing 1 PA(UL94V-0 ʣ ----
2 Insulator 1 PBT(UL94V-0 ʣ ----
3 GT1-1P-2428/1.6C Crimp terminal 1 Brass Tin plating
4 Outer terminal 1 Brass Tin plating
5 GT1-1S-HU Housing 1 PA(UL94V-0 ʣ ----
6 Insulator 1 PBT(UL94V-0 ʣ ----
7 GT1-1S-2428/1.6C Crimp terminal 1 Phosphor bronze Tin plating
8 Outer terminal 1 Brass Tin plating
BTest Data (Using Semi-rigid Cable)
Part Number CL No. L1 L2 L3Part Number CL No. L1 L2 L3 GT1-1S-2428/1.6C GT1-1P-2428/1.6C GT1-1S-30/1.6C GT1-1P-30/1.6C GT1-1S-2022/2.9C GT1-1P-2022/2.9C 3.8 751-0001-3 751-0002-6 751-0029-2 751-0030-1 751-0015-8 751-0014-5 4.9 6.8 11.3 6 10.5 GT1-1S-30/2.9C GT1-1P-30/2.9C GT1-1S-2428/F5C GT1-1P-2428/F5C GT1-1S-30/F5C GT1-1P-30/F5C 4.9 6.8 11.3 Strip Length 1 Crimp the cable to the terminal. 2 Insert the terminal in the housing until is fully locked.
3 Completion
Coaxial Cable Terminal Finish Diagram
Terminals for coaxial shielded cable Item Material Finish Insulator PBT Color: Dark gray Crimp terminal Brass Tin plating Outer terminal Brass Tin plating Note: Products marked with an asterisk (*) indicate polyethylene foam insulation. Part Number CL No. GT1-1P-2428/1.6C GT1-1P-30/1.6C GT1-1P-2022/2.9C GT1-1P-30/2.9C GT1-1P-2428/F5C GT1-1P-30/F5C GT1-1P-2428/F4C 751-0002-6 751-0030-1 751-0014-5 751-0031-4 751-0034-2 751-0038-3 751-0047-4 Inner Insulator Diameter Outer Diameter Packaging 1.5 to 2.0mm 2.6 to 3.4mm 0,800 2.8 to 3.5mm 2.5 to 3.5mm 4.0mm 0,6004.6 to 5.0mm Note: Products marked with an asterisk (*) indicate polyethylene foam insulation. Part Number 0,800 GT1-1S-2428/1.6C GT1-1S-30/1.6C GT1-1S-2022/2.9C GT1-1S-30/2.9C GT1-1S-2428/F5C GT1-1S-30/F5C GT1-1S-2428/F4C 751-0001-3 751-0029-2 751-0015-8 751-0032-7 751-0033-0 751-0037-0 751-0046-1 #24 to 28 or equivalent #30 or equivalent #20 to 22 or equivalent #30 or equivalent #24 to 28 or equivalent #30 or equivalent #24 to 28 or equivalent Conductor Size (AWG)CL No. Inner Insulator Diameter 1.5 to 2.0mm 2.6 to 3.4mm 4.6 to 5.0mm 2.8 to 3.5mm 2.5 to 3.5mm 4.0mm Outer Diameter Packaging 1,200 Indication of Conductor Size (AWG) #24 to 28 or equivalent #30 or equivalent #20 to 22 or equivalent #30 or equivalent #24 to 28 or equivalent #30 or equivalent #24 to 28 or equivalent Conductor Size (AWG) F Connector Terminals M Connector Terminals Indication of Conductor Size (AWG) Item Material Finish Insulator PBT Color: Dark gray Crimp terminal Brass Tin plating Outer terminal Brass Tin plating
For Single-Conductor coaxial shielded cable Part Number CL No. Item Material Finish Color Housing PA ---- Light gray GT1-1PP-HU 751-0007-0 Ground plate Brass Tin plating ---- Press fitting nut Brass Nickel ---- Part Number CL No. Material Color GT1-1S-HU 751-0003-9 PA Light gray Part Number CL No. Material Color GT1-1P-HU 751-0004-1 PA Light gray F Connectors Housing M Connectors Housing Panel Housing
Part Number CL No. Item Material Finish Color Housing PBT ---- Light gray Insulator PBT ---- Dark gray GT1-1P-DS 751-0006-7 0.64X1.1 Terminal Brass Tin plating ---- Outer terminal Brass Tin plating ---- Ground terminal Stainless ---- ---- Use mounting screws of M3 with nominal diameter 3L-6 (for a panel thickness of 0.16mm) Part Number CL No. Item Material Finish Color Housing PBT ---- Light gray Insulator PBT ---- Dark grayGT1-1P-DSA 751-0005-4 0.64X1.1 Terminal Brass Tin plating ---- Outer terminal Brass Tin plating ---- Use mounting screws of M3 with nominal diameter 3L-6 (for a panel thickness of 0.16mm) BRecommended Board Mounting Pattern Printed Circuit Type (Right angle) For outer conductor For inner conductor Printed Circuit Type (Straight Dip Type) BRecommended Board Mounting Pattern For outer conductor For inner conductor
Note: Mates only with GT1K-1P-DS and GT1K-1PA-DS. * Refer to Page 14 for use of the GT1K-1P-HU retainer. Note 1: Mates only with GT1K-1S-HU. Note 2: Use mounting screws of M3 with nominal diameter 3L-6 (for a panel thickness of 0.16mm) For Single-Conductor coaxial shielded cable Part Number CL No. Material Color GT1K-1S-HU 751-0016-0 PBT Light gray BShown with inserted retainer BRecommended Board Mounting Pattern Part Number CL No. Item Material Finish Color Housing PBT ---- Light gray Insulator PBT ---- Dark gray GT1K-1P-DS 751-0017-3 0.64X1.1 Terminal Brass Tin plating ---- Outer terminal Brass Tin plating ---- Cover Stainless Nickel ---- Note 1: Mates only with GT1K-1S-HU. Note 2: Use mounting screws of M3 with nominal diameter 3L-6 (for a panel thickness of 0.16mm) Part Number CL No. Item Material Finish Color Housing PBT ---- Light gray Insulator PBT ---- Dark grayGT1K-1PA-DS 751-0035-5 0.64X1.1 Terminal Brass Tin plating ---- Outer terminal Brass Tin plating ---- F Connectors Housing (Integrated retainer type) For outer conductor For inner conductor M Connectors Printed Circuit Board Type (Right-angle Dip Top Lock Type) Printed Circuit Board Type (Right-angle Dip Side Lock Type) BRecommended Board Mounting Pattern For outer conductor For inner conductor Panel
BMethod of Using the GT1K-1S Retainer a. Insert so that the terminal locking tab is inserted between the top surface of the terminal and the housing. b. Push in while changing the angle of the retainer until the front surface comes to a stop. c. Press the rear portion of the retainer and snap it into the locked position. d. If locking is not complete, press the rear portion of the retainer again while pulling it backward. * Check that all locations are locked.
Two-position type-Each Single-Conductor coaxial Cable Part Number CL Number Material Color GT1-2S-HUʢ20ʣ 751-0011-7-20 Light gray GT1-2S-HUʢ20ʣ 751-0011-7-20 PBT Orange GT1-2S-HUʢ21ʣ 751-0011-7-21 Blue Note: Retainer is optional. A Configuration Part Number CL No. GT1-2S-33R GT1-2S-53R GT1-2S-55R 751-0045-9 751-0043-3 751-0044-6 Material PBT White Dark gray Light blue o/3 o/5 o/5 o/3 o/3 o/5 Color Cable Dia. o/A o/B BGT1-2S-HU Shown with temporarily inserted retainer BGT1-2PP-HU Shown with temporarily inserted retainer Note: Mount this item after provisional insertion into the housing, or after terminal insertion. Part Number CL Number Material Color GT1-2P/S-R 751-0013-2 PBT Dark gray Note 1: This item should be mounted to the GT1-2PP-HU housing after the insertion of terminals. Note 2: Retainer is optional. F Connectors Housing Retainer (Used with GT1-2S-HU) Part Number A Configuration BShown with inserted retainer Retainer (used with GT1-2S-HU and GT1-2PP-HU)
A Configuration Part Number CL No. GT1-2PP-33R GT1-2PP-53R GT1-2PP-55R 751-0042-0 751-0040-5 751-0041-8 White Dark gray Light blue o/3 o/5 o/5 o/3 o/5 o/3 Color Cable Dia. o/A o/B Material Color White PBT Dark gray Light blue Note 1: This item should be mounted to the GT1-2PP-HU housing after the insertion of terminals. Note 2: Retainer is optional. Part Number CL No. Color Remarks GT1-2PP-HU(10) 751-0010-4-20 Light gray With ground terminal GT1-2PP-HU(10) 751-0010-4-10 Light gray Without ground terminal GT1-2PP-HU(20) 751-0010-4-20 Orange With ground terminal GT1-2PP-HU(21) 751-0010-4-21 Blue With ground terminal GT1-2PP-HU(40) 751-0010-4-40 Orange Without ground terminal GT1-2PP-HU(41) 751-0010-4-41 Blue Without ground terminal Note: Retainer is optional. Item Material Finish Color: Light gray Housing PBT Color: Orange Color: Blue Ground terminal Brass Tin plating BRecommended Mounting Bracket Dimensions (T=1.5mm) M Connectors Housing Mounting bracket attachment side Ground terminal Tin plating Retainers (Used with GT1-2PP-HU) Part Number A Configuration BShown with inserted retainer Bracket Mounting portion
5,000 3,000 GT7-2022SCF GT7A-2022SCF 757-0001-1 757-0003-7 #20 to 22 #20 to 22 Part Number CL No. Inner Insulator Diameter 1.4 to 2.4mm 2.6 to 3.1mm 19 Dimension A Packaging Copper alloy Material Tin plating FinishConductor Size (AWG) Note 1: Sold by the reel. (See above table for number of Packaging.) Note 2: This component is used only with applicable HRS housings. Note 1: Sold by the reel. (See above table for number of Packaging.) Note 2: This component is used only with applicable HRS housings. * Reserved for product expansion 757-0002-4 757-0004-0 #16 to 18 #20 to 22 #20 to 22 CL No. Inner Insulator Diameter 1.8 to 2.7mm 1.4 to 2.4mm 2.6 to 3.1mm Packaging 3,000 5,000 3,000 Material Brass Finish Tin plating Conductor Size (AWG) Power Supply Terminals F Connector Terminals M Connector Terminals 5,000 3,000 GT7-2022SCF GT7A-2022SCF 757-0001-1 757-0003-7 #20 to 22 #20 to 22 Part Number CL No. Inner Insulator Diameter 1.4 to 2.4mm 2.6 to 3.1mm 19 Dimension A Packaging Copper alloy Material Tin plating FinishConductor Size (AWG)
Combination Type (One Single-Conductor Coaxial Cables + One Power contact) Note: Retainer is optional. Part Number CL No. Material Color GT1-1/1S-HU 751-0026-4 PBT Light gray Note: Mount this item after provisional insertion into the housing, or after terminal insertion. Part Number CL Number Material Color GT1-1/1S-R 751-0028-0 PBT Dark gray F Connectors Housing Retainer (Used with GT1-1/1S-HU)
Part Number CL No. Remarks GT1-1/1PP-HU (00) 751-0025-1-10 1.5mm With ground terminal GT1-1/1PP-HU(10) 751-0025-1-10 1.5mm Without ground terminal GT1-1/1PP-HU(11) 751-0025-1-11 1.0mm With ground terminal Note: Used with separate retainer (GT1-1/1PP-R). Note: Mount this item after provisional insertion into the housing, or after terminal insertion. Item Material Finish Housing PBT Light gray Ground terminal Phosphor bronze Tin plating Part Number CL Number Material Color GT1-1/1PP-R 751-0027-7 PBT Dark gray BRecommended Mounting Bracket Dimensions (T=1.5mm) M Connectors Housing Mounting bracket attachment side Tin plating Mounting bracket attachment side Retainer (exclusively for GT1-1/1PP-HU)
Combination Type (Two Single-Conductor Coaxial Cables + One Power contact) Note1: Mates only with GT1-2/1PP-DS and GT1-2/1PP-HU. Note2: Used with separate retainer (GT1-2/1S-R). Part Number CL No. Material Color GT1-2/1S-HU 751-0019-9 PBT Light gray Note: Mount this item after provisional insertion into the housing, or after terminal insertion. Part Number CL No. Material Color GT1-2/1S-R 751-0021-0 PBT Dark gray F Connectors Housing Retainer (used with GT1-2S-HU and GT1-2PP-HU)
Note1: Mates only with GT1-2/1S-HU. Note2: Used with separate retainer (GT1-2/1PP-R). Item Material Finish Housing PBT Light gray Ground terminal Phosphor bronze Tin plating Part Number CL No. Remarks GT1-2/1PP-HU(00) 751-0018-6-10 1.5mm With ground terminal GT1-2/1PP-HU(10) 751-0018-6-10 1.5mm Without ground terminal GT1-2/1PP-HU(11) 751-0018-6-11 1.0mm With ground terminal Note: Mount this item after provisional insertion into the housing, or after terminal insertion. Part Number CL Number Material Color GT1-2/1PP-R(22) 751-0020-8-22 PBT Dark gray Part Number CL No. Part Material Finish Color Housing PBT ---- Light gray Ground terminal Phosphor bronze Tin plating ---- Ground plate Brass Tin plating ---- GT1-2/1PP-DS 751-0022-3 Tub terminal for DS 070 Brass Tin plating ---- 0.64X1.1 Terminal Brass Tin plating ---- Insulator PBT ---- Dark gray Outer terminal Brass Tin plating ---- Note1: Mates only with GT1-2/1PP-DS and GT1-2/1PP-HU. Note 2: Use mounting screws of M3 with nominal diameter 3L-6 (for a panel thickness of 1.6mm) M Connectors Housing Mounting bracket attachment side BRecommended Mounting Bracket Dimensions (T=1.5mm) Mounting bracket attachment side Ground terminal Tin plating Retainer (used with GT1-2/1PP-HU) Printed Circuit Board Type Ground terminal Ground terminal Ground terminal For inner conductor For outer conductor Panel Board BRecommended Board Mounting Pattern BRecommended Panel Cut-out
Products Listed Below are of the Combination Type (Two Terminals for Use with Single-Conductor Shielded Cable + One Power Supply Terminal) with Key Positions that Differ from the Products Listed on Previous Pages Note1: Mates only with GT1-2/1P-DS. Note2: Used with separate retainer. Part Number CL No. Material Color GT1-2/1S-HU(A)(21) 751-0024-9-21 PBT Light gray GT1-2/1S-HU(A)(21) 751-0024-9-21 PBT Blue Item Material Finish Color ---- Light grayHousing PBT ---- Blue 0.64X1.1 Terminal Brass Tin plating ---- Insulator PBT ---- Dark gray Outer terminal Brass Tin plating ---- Tub terminal for DS 070 Brass Tin plating ---- Note1: Mates only with GT1-2/1S-HU(A). Note 2: Use mounting screws of M3 with nominal diameter 3L-6 (for a panel thickness of 1.6mm) Part Number CL No. Color GT1-2/1P-DS(21) 751-0023-6-21 Light gray GT1-2/1P-DS(21) 751-0023-6-21 Blue F Connectors Housing M Connector Printed Circuit Board Type BRecommended Board Mounting Pattern BRecommended Panel Cut-out Ground terminal For inner conductor For outer conductor Panel Board
BMating, Cross-Sectional View (51%4ʴ(54)6ʢ"ʣ Part Number Part Number Used Material PBT PBT Brass Brass PBT PBT PBT Phosphor bronze Brass Finish UL94V-0 UL94V-0 Tin plating Tin plating UL94V-0 UL94V-0 UL94V-0 Tin plating Tin plating Housing Insulator 0.64 X 1.1 terminal Outer terminal Housing Retainer Insulator Crimp terminal Outer terminal GT1-2/1P-DS(A) GT1-2/1S-HU(A) GT1-2/1S-HU(A) GT1-1S-2428/1.6C Currently, the GT7 Series terminals are used for the power supply of the GT1 Series combination type. The coupled, cross-sectional view of the GT7 terminals of the GT1-2/1 Series appears below. Part Number GT1-1/1S-HU GT1-2/1S-HU GT1-1/1PP-HU GT1-2/1PP-HU Terminal GT7-2022SCFɺGT7A-2022SCF GT7-2022PCFɺGT7A-2022PCF Part Number GT1-2/1PP-HU GT1-2/1PP-R GT7-2022PCF GT1-2/1S-HU GT1-2/1S-R GT7-2022SCF Examples of Printed Circuit Board Type and Cable Type Mating, Top View Cross Section AA Example of Cable-to-Cable Type Cross Section AA Mating, Top View
Mounted Condition Installed Note 1: This product can be attached to GT1-1PP-HU, GT1-1/1PP-HU, and GT1-2/1PP-HU. Note 2: Please use the tin plated item when making a ground connection. Part Number CL No. Material Finish GT-BK(01) 751-0039-6-22 Tin plating GT-BK(01) 751-0039-6-01 SPCC Zinc plating Note: This product cannot be used with GT1K-1S-HU. Part Number CL No. Item Material Finish Top Shield Cover Tin platingGT1-1S-1.6CSB 751-0009-5 Bottom Shield Cover SPCC Zinc plating Note: The product normally has sufficient performance without using the shield plate; however, when used in especially high fre quency bands (e.g., 1 GHz and higher), use of the shield plate is recommended so that even higher shielding effectiveness may be obtained. Part Number CL No. Item Material Finish Top Shield CoverGT1-1P-1.6CSB 751-0008-2 Bottom Shield Cover Brass Tin plating Accessories Brackets (for M Connector Housing) F Terminal Shield Cover M Terminal Shield Plate Mounted Condition Installed
Automatic Crimping Machine Item Specification Remarks Specification 1.5ton Stroke Length 30mm Number of strokes 200spm(50Hz) 240spm(60Hz) Weight 75kg Motor 0.2kW AC100V Crimping speed 2000 to 4000 per day Part Number CM-105 Specifications Hand Tool Hand Press BTermination Tools Users manuals are available. Please ask your Hirose Electric account representative. *Crimp height setting tables are available for each cable type. Please contact your nearest Hirose Electric account representative. Different cables will require different crimp height settings.
1) For one lance 2) For two lances 1 Insert the extraction tool from the coupling end. 2 Push the lance upward and pull out the terminal. 1 Insert the extraction tool from the coupling end. 2 Push and separate both lances and pull out the terminal. BTerminal Extraction Tool Part Number CL No. Used with connectors GT-PO(A) 780-0006-2 GT1K-1S-HU GT1-2S-HU GT1-2PP-HU GT1-1/1S-HU GT1-1/1PP-HU GT1-2/1S-HU GT1-2/1PP-HU GT1-2/1S-HU(A) Part Number CL No. Used with connectors GT1-C-PO 902-5020-1 GT1-1S-HU GT1-1P-HU GT1-1PP-HU