GPP10 FRIWO | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

The GPP-series can be variably equipped with the mains plugs as shown. Your applications and products can be sold and used worldwide due to the set of all country mains plugs which can be inserted with the unit. Mobility and dependability with respect to the use of the product are increased in this way and provide a constant level of functionality and availability – wherever you are in the world. Beyond that, these plug modules help reducing the logistic complexity, avoiding the need to plan and stock mains adapters and chargers in various mains plug configurations. In countries with mains plugs which are not covered by EURO, UK, USA/Japan and Australia mains plug types, the IEC adapter with the 2- pin IEC 320 C8 socket provides a standardized alternative. Exchangeable Primary Adapters AustraliaUSA / Japan UK 76,5 mm 28,3 mm 28,3 mm EURO 40 mm Primary Adapters Type Order No. EURO UK USA/Japan Australia IEC 1827417 1827420 1827422 1827425 1827428 IEC

10 Watt

Applications

■ Blood analyzer ■ Patient monitors ■ Measuring instruments ■ Laboratory equipment Characteristics ■ Universal input 100 to 240 V AC ■ Interchangeable primary adapters ■ Constant voltage, current limited ■ Green LED indicator ■ Low leakage current ≤ 10 µA ■ Low standby power ■ Continuously short circuit proof Technical Data Input voltage 100 to 240 V AC Input current 250 mA Frequenzy 50 to 60 Hz Effi ciency 80% typ. at full load EMV Conforms to EN 55011, EN 55014, EN 55022 / B, FCC 47 part 15, EN 61000-3-2, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 610004-5, EN 61000-4-11 Output voltage tolerance + 5%, -7% Environmental specifi cation Operating temp. 0 to 40° C at maximum load Storage temp. -40 to 70° C Humidity 5% to 95% non condensing Input transient susceptibility Complies with IEC 61000 requirements Safety specifi cations Standards Fulfi ls Class II SELV for the following applications: IEC 60601-1, UL 2601, VDE, CE label, fulfi ls medical application class B/BF/CF Output data Voltage Current Ripple Volt. Order No. 5 V 6 V 7,5 V 9 V 12 V 15 V 18 V 24 V 1600 mA 1400 mA 1200 mA 1000 mA 800 mA 700 mA 560 mA 420 mA 75 mV pp 75 mV pp 75 mV pp 75 mV pp 75 mV pp 75 mV pp 125 mV pp 125 mV pp 1950062 1950064 1950063 1950068 1950082 1950067 1950066 1950065 Worldwide Switchmode Power Supply GPP 10 Conforms to IEC 60950 ■ Offi ce equipment ■ Data transmission devices ■ IT equipment ■ Measurement and weighing technology Characteristics ■ Universal input 100 to 240 V AC ■ Interchangeable primary adapters ■ Constant voltage, current limited ■ Light weight and universal use ■ Low standby power ■ Continuously short circuit proof Technical Data Input voltage 100 to 240 V AC Input current 250 mA Frequenzy 50 to 60 Hz Effi ciency 80% typ. at full load EMV Conforms to EN 55011, EN 55014, EN 55022 / B, FCC 47 part 15, EN 61000-3-2, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 610004-5, EN 61000-4-11 Output voltage tolerance + 5%, -7% Environmental specifi cation Operating temp. 0 to 40° C at maximum load Storage temp. -40 to 70° C Humidity 5% to 95% non condensing Input transient susceptibility Complies with IEC 61000 requirements Safety specifi cations Standards Fulfi ls Class II SELV for the following applications: EN 60950 / IEC 60950,UL 60950, CSA 950 (cUL), VDE, CE-label Output data Voltage Current Ripple Volt. Order No. 5 V 6 V 7,5 V 9 V 12 V 15 V 18 V 24 V 1600 mA 1400 mA 1200 mA 1000 mA 800 mA 700 mA 560 mA 420 mA 75 mV pp 75 mV pp 75 mV pp 75 mV pp 75 mV pp 75 mV pp 125 mV pp 125 mV pp 1827490 1827491 1827492 1827493 1827494 1827495 1827496 1827497 Worldwide Reliability specifi cations MTBF calculation 200,000 hours at maximum load levels and an ambient temperature of 25° C (in correspondence with MIL-HDBK-217) Mechanical specifi cation Weight approx. 113 g Plug connector AC input: FRIWO exchangeable mains plug system: EURO, UK, USA / Japan, Australia, IEC DC output: Universal output plug system Market leading Medical power supplies 100 to 240 V input voltage without earthing, leakage current ≤ 10 µA Reliability specifi cations MTBF calculation 200,000 hours at maximum load levels and an ambient temperature of 25° C (in correspondence with MIL-HDBK-217) Mechanical specifi cation Weight approx. 113 g Plug connector AC input: FRIWO exchangeable mains plug system: EURO, UK, USA / Japan, Australia, IEC DC output: Universal output plug system 35,5 mm 66 mm 58 mm 35,5 mm 66 mm 58 mm A pplications Offi ce equipment Data transmission devices IT equipment Measurement and weighing technology Technical Dat a Input voltage 100 to 240 V AC A Technical Dat a Input voltage 100 to 240 V AC