CONDOR DC POWER SUPPLIES INC.

2311 STATHAM PKWY

OXNARD, CA 93033 + 805-486-4565 RATINGS Input: 100-240 VAC, 5.5 A, 50/60 Hz Output: Maximum Continuous Output Power at 50°C With external 26 cfm Airflow = 200 W Standard Models: Model Output #1 1 I sc Output #2 1 I sc Output #3 I sc Output #4 2 I sc GPM200A +5V 26A 5 25A +12V 8.0A 15A -12V 1.2A 2A 12V 4.0A 2A GPM200B +5V 26A 5 25A +12V 8.0A 15A -5V 1.2A 2A 12V 4.0A 2A GPM200D +5V 26A 5 25A +24V 5.0A 15A -12V 1.2A 2A 12V 4.0A 2A GPM200E +5V 26A 5 25A +24V 5.0A 15A -15V 1.2A 2A 15V 4.0A 2A GPM200F +5V 26A 5 25A +12V 8.0A 15A -12V 1.2A 2A 5V 4.0A 2A Special Models: (Place Code Letters for desired outputs from Table below; example = GPM200-BAA) Output #1 1 Output #2 1 Output #3 Output #4 2 +5V 26A 5 B = +12V 8.0A A = -5V 1.2A Q = -5V 2.4A A = 5V 4.0 A (For all C = +15V 8.0A B = -12V 1.2A R = -12V 2.4A B = 12V 4.0A models) D = +24V 5.0A C = -15V 1.2A S = -15V 2.4A C = 15V 4.0A D = 24V 2.0A Notes: 1. The combined loads of Outputs No. 1 and No. 2 mu st not exceed 32 A. 2. Isolated output which may be referenced as a pos itive or negative voltage. 3. Maximum Operating Relative Humidity 96%, no cond ensation. 4. I sc = Maximum output short circuit current. 5. Minimum load current = 4A. SAFETY DECLARATION: Condor DC Power Supplies, Inc. declares under our sole responsibility that all models listed above are in conformity with the applicable requirements of EN60950 following the provisions of the Low Voltage Directive 73/23/EEC. CERTIFICATION: All models are Certified to be in compliance with the applicable requirements of CA-08), IEC 601-1 (1988), EN 60601-1: 1990 and VDE 0750 T1 12.91. CLASSIFICATION: (5.1) Protection against electric shock = Class I (In accordance with sub- (5.2) Degree of protection against electric shock = Signal output or intermediate clause 5 of IEC 601-1) (5.3) Protection against har mful ingress of water = Ordinary (no protection) (5.5) Has not been evaluated for use in the presen ce of a flammable anaesthetic mixture with air, oxygen, or nitrous oxide. This evaluation is made on the end equipment by the OEM. (5.6) Mode of operation = Continuous CAUTION: When performing Dielectric Strength Tests, catastro phic failure of the unit may result if a Dielectric Strength test voltage greater than 1800 Vac is applied between primary and secondary circuits. The components providing isolation from primary to secondary cannot be tested while installed in the power supply without overstressing basic (primary t o ground) insulation. All isolating components are individually 100% tested at 4800 Vac prior to installation. 41-33222-0001 Rev. E 1/29/02 Page 1 of 2 GPM200 SERIES INSTALLATION INSTRUCTIONS

ISOLATION: The creepage distance between primary and ground is 4 mm minimum; between primary and secondary circuits is 8 mm minimum. Secondary to ground cree page is not defined or controlled. The output comm on is bypassed to ground using a capacitor. The required creepage an d clearance distances from primary circuits to grou nd and secondary circuits must be maintained after installation to preserve the intended safety. GROUNDING: The Protective Earth (ground) terminal must be bond ed to Protective Earth in the host equipment. Using the Protective Earth terminal on the supply for groundi ng the host equipment is not recommended. A separa te dedicated grounding point should be used. OUTPUTS: All output commons should be connected to Protect ive Earth in the end application. The output(s) ar e intended for Protectively Earthed Signal Output and Intermediate Circuits only. The output(s) are not acceptable for patient connection without additional isolation. All DC outputs are SELV under normal and single fault conditions. OVERVOLTAGE PROTECTION: Only output #1 is monitored for an overvoltage con dition. The trip-point for a 5 volt output is 5.6 to 6.8 volts. In some applications w here an overvoltage condition could result in a haz ard as defined in applicable safety standards, redundant or additional overvoltage protection may be required. Consult factory for details. TEMPERATURES : The maximum operating temperatures of certain sa fety components, as defined in the applicable safet y standards, must not be exceeded after installation to preserve the intended safety. The output power, ambient air temperature and the availability, amount, direction and/or restriction of airflow influence the temperatures of these components. OVERCURRENT PROTECTION: The internal fuse is located in the phase lead only . EN 60601-1 requires that both supply leads (phase and neutral) be protected again st overcurrent. Complete overcurrent protection mu st be provided in the host equipment. Fuse ratings must not exceed that specified for the internal fuse, must meet the requ irements of EN 60601-1 and be acceptable for the country in which the host equipment is to be installed. WARNING! RISK OF FIRE! A blown internal fuse is an indication of catastrophic failure of circuit component(s). Repair must be performed by Condor authorized personnel. Refer to fuse marking on the supply for rating. WARNING! SHOCK HAZARD! Dangerous voltages are present on some components, printed wiring traces and heatsinks. Attention, Consult Accompanying Documents Alternating Current Attention, Dangerous Voltages Earth (Ground) EXPLANATION OF SYMBOLS C O N N E C T I O N S TB1 AC INPUT J2 CONTROL CONNECTOR TB2 DC OUTPUTS

1 Line 1 Power Fail 1,2 Output #1 (+)

2 Neutral 2 Output #1 (-) Sense 3,4,5 Common (Retur n)

3 Ground 3 Output #1 (+) Sense 6 Output #2 (+)

4 No Connection 7 Output #3 (-)

J2 Mating Connector = Amp 64044x-4 where x = 0 to 4 8 Output #4 (+) WARNING : Do not exceed 15A per terminal on TB2 9 Output #4 (-) Condor DC Power Supplies Inc. will not be liable fo r the safety, reliability or performance of these p ower supplies if a) any changes, modifications or repairs are carried out by other t han authorized agents of Condor DC Power Supplies I nc., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA, and/or IEC safety standards. 41-33222-0001 Rev. E 1/29/02 Page 2 of 2