Typical Thermal Performance Part Number Height Natural Convection Power Dissipation† Forced Convection Thermal Resistance‡ 001 0.25" 5W 5.8˚ C/W 002 0.50" 7W 3.2˚ C/W 003 1.00" 11W 2.0˚ C/W 004 0.13" TBD TBD Part Numbers Standard Model Number Input Voltage Output Voltage Max Current GPBR52V04A* 48V 52V 4A BOLERO HV DC/DC CONVERTERS 48V Input – 52VDC – 4A Output POWER PRODUCTS GPBR52V04A GPBR52V04A – 1/2 Brick Bolero HV Series
- Industry standard pinout and footprint
- Highest efficiency in the industry: 92% at 52V, 4A; 91% at 52V, 2A
- No heat sink required (baseplate standard)
- Very low common-mode noise for a commercial DC/DC converter
- Two-stage input filter
- Constant switching frequency, 330 kHz
- Remote sense
- Single board SMT construction
- Low profile, 0.43"
- Optional low profile heat sink or baseplate for improved thermal performance
- Header with M3 metal inserts for mechanical connection to PCB Typical Characteristics Control Functions
- Output setpoint accuracy: ± 2% • Microprocessor controlled
- Load regulation: ± 0.25% • Primary-side enable, choice of logic
- Line regulation: ± 0.25%
- Regulation over line, load and temperature: ± 2% Protection Features
- Low output ripple
- 50% output trim-down • Over temperature protection
- Supports IEEE 802.3af power over LAN • Over voltage protection
- 2250V isolation • Over current protection
- Over/Under input voltage protection
Ordering Information
- Options: R = Heat Sink-Ready M = 0.145" Pins (± .01") G = Case Ground Pin Bolero HV Heat Sink Example Part Number: (All options) GPBR52V04A MRG 00X Part Number Options: Optional Pin Lengths E = 0.18" M = 0.145" (Std.) S = 0.12" Heat Sink-Ready Plate (Std.) Case Ground Pin (Std.) Heat Sink 001 = 0.25" 002 = 0.50" 003 = 1.00" 004 = 0.13" † @ 60 ˚ C rise heat sink to ambient ‡ @ 300'/min. ©2011 Bel Fuse Inc. Specifications subject to change without notice. 051811 Bel Power Inc. 155 Flanders Road, Westborough, MA 01581 • Tel 508-870-9775 • Fax 508-870-9796 • www.belpower.com page 1
©2011 Bel Fuse Inc. Specifications subject to change without notice. 051811 POWER PRODUCTS GPBR52V04A Bel Power Inc. 155 Flanders Road, Westborough, MA 01581 • Tel 508-870-9775 • Fax 508-870-9796 • www.belpower.com BOLERO HV DC/DC CONVERTERS 48V Input – 52VDC – 4A Output page 2 Input Specifications Parameter Min Typical Max Units Operating Input Voltage 36 48 75 V DC Input Current 7 A Input Capacitance 5 μF Input Hysteresis, Low Line 2 V DC 1. During short circuit, converter will shut down and attempt to restart once per second. The average current during this condition will be very low and the device can be safely left in this condition continuously. 2. 50% load change only resulted in 1% output voltage step. Output Specifications Parameter Min Typical Max Units Setpoint 51.45 52.50 53.55 V DC Voltage Ripple, 180μF Load Capacitance 30 mV RMS Voltage Ripple, 180μF Load Capacitance 80 mV P–P Current Range 0 4 A Current Limit Inception 100 120 %I OUT Short Circuit Current1 6A Settling Time to ± 1%2 1m S Turn-on Time to 98% Vnom 40 mS Output Overshoot at Turn-on None %V OUT Trim Range, Lucent 1/2 Brick Trim 50 1 10 %VOUT Over Voltage Protection, Latching 1 20 %VOUT VIN = 48VDC, TA@25˚ C, 300 LFM Airflow, VOUT = 52VDC, IOUT = Full load unless otherwise noted. COUT = 180μF Al-Elec. Available output power depends on ambient temperature and good thermal management. (See application graphs for limits.)
Bel Power Inc. 155 Flanders Road, Westborough, MA 01581 • Tel 508-870-9775 • Fax 508-870-9796 • www.belpower.com ©2011 Bel Fuse Inc. Specifications subject to change without notice. 051811 POWER PRODUCTS GPBR52V04A BOLERO HV DC/DC CONVERTERS 48V Input – 52VDC – 4A Output page 3 General Specifications Operating Temperature, Baseplate -40˚ C to + 100˚ C Storge Temperature -55˚ C + 125˚ C Relative Humidity 10% to 95% RH, Non-condensing Vibration 2 to 9 Hz, 3mm disp., 9 to 200 Hz, 1g Material Flammability UL V-0 Weight 55 grams MTBF Bellcore TR-332 1.6 million hours Approvals and Standards UL and c-UL Recognized Component, TUV, UL1950, CSA 22.2 No. 950, IEC/EN 60950 Pending. EMC Characteristics: Designed to meet emission and immunity requirements per EN55022, CISPR 22, Class B, and CISPR 24. An external fuse shall be used to comply with the requirements. Isolation Specifications Parameter Min Typical Max Units Isolation Test Voltage, Input/Output (Basic) 2250 V DC Isolation Resistance 10 M 7 3. PCB less than 130˚ C.
Features
Parameter Min Typical Max Units Over Temperature Protection, Thermal Sensor, Latching 3 115 ˚ C Input, Output Ripple Frequency, Fixed 330 kHz
©2011 Bel Fuse Inc. Specifications subject to change without notice. 051811 POWER PRODUCTS GPBR52V04A Bel Power Inc. 155 Flanders Road, Westborough, MA 01581 • Tel 508-870-9775 • Fax 508-870-9796 • www.belpower.com BOLERO HV DC/DC CONVERTERS 48V Input – 52VDC – 4A Output page 4 Application Notes CoolConverter™ Bel Power’s Proprietary CoolConverter™
- Patented single-stage power conversion architecture, control and magnetic design allow unprecedented power density and efficiency in an isolated power supply. Protection and Control Valid Input Voltage Range The converter measures the input voltage and will not allow operation outside of the input voltage specification. As shown by the graphs, hysteresis is added to both the high and low voltage to prevent the converter from turning on and off repeatedly when the voltage is held near either voltage extreme. At low line, this assures the maximum input current is not exceeded; at high line, this assures the semiconductor devices in the converter are not damaged by excessive voltage stress. ON/OFF Logic Option The ON/OFF control logic can be either Negative (standard) or Positive to enable the converter. For Negative logic, the ON/OFF pin is brought to below 1.0V with respect to the –INPUT pin to enable the converter. The pull-down must be able to sink 100μA. For Positive logic, the ON/OFF pin is brought to greater than 4.0V with respect to the –INPUT pin and be limited to less than 10V. To request the Positive logic version, add the suffix (P) to the standard part number. The ON/OFF pin has a built-in pull-up resistor of approximately 100k7 to +5V. Output Over Voltage Protection The output voltage is constantly monitored by the microprocessor with a redundant secondary-side measurement circuit that both shuts down the duty cycle and triggers the microprocessor to shut down. If the output voltage exceeds the over voltage specification, the microprocessor will latch the converter off. To turn the converter on required either cycling the ON/OFF pin or power to the converter. This advanced feature prevents the converter from damaging the load if there is a converter failure or application error. If non- latching is required, consult factory.
- An advanced microcontroller reduces parts count while adding features, performance and flexibility in the design. È x Î Ó ä Îä Î{ ÎÇ ÎÈÎÓ ÎÎ ÎxΣ È x Î Ó ä ÇȰx Çn°x nä°x ǰxÇǰx Çn nä ÇÇÇ
Bel Power Inc. 155 Flanders Road, Westborough, MA 01581 • Tel 508-870-9775 • Fax 508-870-9796 • www.belpower.com ©2011 Bel Fuse Inc. Specifications subject to change without notice. 051811 POWER PRODUCTS GPBR52V04A BOLERO HV DC/DC CONVERTERS 48V Input – 52VDC – 4A Output page 5 CoolConverter™ Trim-down Increase in Output Voltage (%) 10000 1000 100 0 1 23456789 1 0 Trim Resistance (kΩ) 52V Trim-up Decrease in Output Voltage (%) 1000 100 0 1 23456789 1 0 Trim Resistance (kΩ) Trim-down RTRIM-DOWN = 100 _ 2k 7$%{ } Trim-up Protection and Control Thermal Shutdown The printed circuit board temperature is measured using a semiconductor sensor. If the maximum rated temperature is exceeded, the converter is latched off. To re-enable the converter requires cycling the ON/OFF pin or power to the converter. If non-latching shutdown is required, consult factory. Control Options As the behavior of the circuit is determined by firmware in the microcontroller, specific requirements, such as:
- non-latching thermal protection
- custom valid input voltage range
- controlled delay from initiating an ON/OFF signal for power sequencing can be accomplished with no change to hardware. The standard behavior was chosen based on system design experience, but customers may have their own requirements. Please contact Bel Power for any special needs. Remote Sense The output voltage is regulated at the point where the sense pins connect to the power output pins. Total sense compensation should not exceed 0.4V or 2% of Vout, whichever is greater. Safety An external input fuse must always be used to meet these safety requirements. External Output Trimming Trim To trim the output voltage higher, connect the required trim resistor from the Trim pin to the +Sense pin. To trim the output voltage lower, connect the required trim resistor from the Trim pin to the –Sense pin. See diagram above. 6 6
BOLERO HV DC/DC CONVERTERS 48V Input – 52VDC – 4A Output GPBR52V04A Efficiency Data Power Dissipation {Ê ÓÊ äÊ nnÊ nÈÊ n{Ê nÓÊ näÊ {ä6Ê6Ê {n6Ê6Ê Èä6Ê6Ê ÎÈ6Ê6Ê {n6Ê6Ê Çx6Ê6Ê ä £Ê Ó ÎÊ >\`Ê ÕÀÀiÌÊ®Ê Start Up Vout (mV) Voltage Ripple 150 100 -50 -100 -150 0 5 10 15 20 25 Time (μS) Vout ÓÊ £ ÊÓä°ä6Ê ÓÊ x°ääÊ6Ê M 10.0ms A Ch2 1.80V /QÊ RÊ 7 7Ê 1. VOUT 20V/div 10mS/div 1. VOUT 50mV/div 2μS/div 2. VOUT 5V/div 10mS/div 10μF ext cap 2MHz BW Line/Load Regulation 53.700 53.600 Output Voltage (V) 53.500 53.400 53.300 53.200 53.100 53.000 52.900 36V Vin 48V Vin 75V Vin 52.800 024 Output Current (A) ©2011 Bel Fuse Inc. Specifications subject to change without notice. 051811 Bel Power Inc. 155 Flanders Road, Westborough, MA 01581 • Tel 508-870-9775 • Fax 508-870-9796 • www.belpower.com page 6
Bel Power Inc. 155 Flanders Road, Westborough, MA 01581 • Tel 508-870-9775 • Fax 508-870-9796 • www.belpower.com ©2011 Bel Fuse Inc. Specifications subject to change without notice. 051811 POWER PRODUCTS GPBR52V04A BOLERO HV DC/DC CONVERTERS 48V Input – 52VDC – 4A Output page 7 Transient Response Transient Response 50% to 75% Load Transients at VIN = 48V@TA = 25˚C 75% to 50% Load Transients at V IN = 48V@TA = 25˚C
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.co Page 8 BOLERO DC/DC CONVERTERS
48 VDC Input - 52 VDC - 4 A Output
Vin=48V without heat sink Vin=48V with 2.3×2.28×1.18(inch)heat sink Maximum junction temperature of semiconductor Maximum junction temperature of semiconductor is derated to 125℃ is derated to 125℃ Heat sink outline
©2011 Bel Fuse Inc. Specifications subject to change without notice.081911 CORPORATE FAR EAST EUROPE Bel Fuse Inc. Bel Fuse Ltd. Bel Fuse Europe Ltd.
206 Van Vorst Street 8F/ 8 Luk Hop Street Preston Technology Management Centre
Jersey City, NJ 07302 San Po Kong Marsh Lane, Suite G7, Preston Tel 201-432-0463 Kowloon, Hong Kong Lancashire, PR1 8UD, U.K. Fax 201-432-9542 Tel 852-2328-5515 Tel 44-1772-556601 www.belfuse.com Fax 852-2352-3706 Fax 44-1772-888366 www.belfuse.com www.belfuse.com page 9 BOLERO HV DC/DC CONVERTERS 48V Input – 52VDC – 4A Output GPBR52V04A Mechanical RoHS Compliance Complies with the European Directive 2002/95/EC, calling for the elimination of lead and other hazardous substances from electronic products. These parts are not however compatible with the higher temperatures associated with lead fr ee solder processes and must be soldered using a reflow profile with a peak temperature of no more than 240˚C. GPBR52V04A 0.43 ±0.01