Greegoo Electric Co.,Ltd Add:Jinye Mansion, Lvzhuang, Liushi, Yueqing, Zhejiang, 325604 P.R. China Homepage://www.greegoo.com E-mail:peter@greegoo.com Solid State Relays GM 10 to 40 Amps Dual SSR Tel: +86 577 62776000 Fax: +86 577 62776006 ■ Rated operational current 10+10 to 40+40 Amps. ■ Rated operational voltage 240V ■ Input Voltage Range 4 to 16 Vdc. ■ 2500 Vrms Optical Isolation.(input/output) ■ Both “Zero Voltage” & phase controllable “Random Switching” versions. Selection guide GM 10 to 40 Amps Dual SSR GM series Solid State Relays are Dual AC relays, Triac or SCR Output. The Triac version of the zero switching r elay is an ine xpensive solu tion for re sistive loads. The zero s witching relay switches on when the AC sine voltage just cr osses zero, and s witches off w hen the current cr osses zero. The SCR Output is Du al SCR Pow er Hybr id technology provides highly efficient thermal management for greatly increased cyclic life. Voltage Controlvoltage Rated operational current 10Amp 15Amp 25Amp 40Amp

240 VAC “Z” 4~16 Vdc GM1024ZD1 GM1524ZD1 GM2524ZD1 GM4024ZD1

240 VAC “R” 4~16 Vdc GM1024RD1 GM1524RD1 GM2524RD1 GM4024RD1

440 VAC “Z” 4~16 Vdc GM1044ZD1 GM1544ZD1 GM2544ZD1 GM4044ZD1

440 VAC “R” 4~16 Vdc GM1044RD1 GM1544RD1 GM2544RD1 GM4044RD1

Greegoo Electric Co.,Ltd Add:Jinye Mansion, Lvzhuang, Liushi, Yueqing, Zhejiang, 325604 P.R. China Homepage://www.greegoo.com E-mail:peter@greegoo.com Solid State Relays GM 10 to 40 Amps Dual SSR Tel: +86 577 62776000 Fax: +86 577 62776006 Specifications PARAMETER Units Specification Limits Input Parameter ᶃ% 10A 15A 25A 40A Control Voltage Range Vdc 4 to16 4 to16 4 to16 4 to16 Input Current (Max.) @=5V/12V mAdc 10/20 10/20 10/20 10/20 Must Turn On Voltage Vdc 4 4 4 4 Must Turn Off Voltage Vdc 1 1 1 1 Reverse Voltage (Max.) Vdc 32 32 32 32 Display LED yes yes yes yes OUTPUT PARAMETER ᶄ Units Specification Limits Load Current Range Arms 10+10 15+15 25+25 40+10 Surge Current, 20 mSec (Max.) Arms 85 115 230 400 Load Voltage Range Vrms 24 to 280 Load Voltage Range Vrms 28 to 280 TRIAC Over voltage Vpk >600 Frequency Range Hz 47 to 63 Off State dv/dt (Min) V/µTFD 200 Off State dv/dt (Min) V/µTFD 500 Off State Leakage Current (Max.) mArms <8 On State Voltage Drop (Max.) Vrms 1.6 Thermal Resistance, (Rthjc) P Turn On Time (Max.) Cycle 1/2 Turn Off Time (Max.) mSec COUPLING PARAMETER Dielectric (Input/Output) Vrms 2500 Dielectric (Input-Output/Base) Vrms 2500 Capacitance pf 10 GENERAI SPECIFICATIONS Ambient temperature range: operating or Storage -30 to +80 P Weight: ( max.): Aluminum Base plate: 130g; Copper Base plate: 99g Base plate: Aluminum or Copper, nickel-plated Case Color: Black