All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Trust the Shield® are trademarks of Ashcroft Inc. For more information, see Ashcroft Brands & Trademarks
FEATURES
Bright LED display of pressure and switch status All stainless steel wetted parts Internal “push-button” configurability allows quick user pressure range changes or relay adjustments External “push-button” allows user to display P1, P2 or DP without opening cover TYPICAL USES Tank level pressure measurement Pump controls Compressor control Filter monitoring HVAC Hydronic cooling/heating systems KEY BENEFITS
- Robust aluminum die cast housing
- Two sensor design well suited for high DP ranges
- Min./Max. feature records, low/high pressure events
- Two polysilicon thin film sensors to achieve wet- wet, high differential pressure measurements
- Monitors/controls a wide variety of wet/dry media PERFORMANCE SPECIFICATIONS Reference Temperature: 75 °F (24 °C) Analog Output: 4-20 mA or 1-5 Vdc Accuracy: ±0.5% of span Includes linearity, hysteresis and repeatability Response Time: 20 ms Output Resolution: ±0.2% of span Stability: ±0.5%/year Pressure Switch Output: Number of Contacts: 2 Response Time: 20 ms-2.0 sec (by user) Type: TTL/CMOS up to 40 Vdc / 200 mA Setting Accuracy: ±1.0% of span Hysteresis: Variable deadband (by user) Display: Accuracy: ±1.0% of span Type: 3½ digits, 10 mm LED ENVIRONMENTAL SPECIFICATIONS Temperature Limits: Storage: Operating: Compensated: −4 °F to 140 °F (−20 °C to 60 °C) 14 °F to 122 °F (−10 °C to 50 °C) 14 °F to 122°F (−10 °C to 50 °C) Thermal Coefficients: (ref. 75°F (24°C)) Zero & Span: ±0.05% of span/°C FUNCTIONAL SPECIFICATIONS Static (Line) Pressure Pressure Range: 75 to ≤300 psi Proof:
2 X Range (URL)
Burst:
10 X Range (URL)
Single Side (Differential) Pressure Range: 75 to ≤300 psi Proof: Burst: Vibration: 5g’s 150Hz Shock Effect: 10g’s 16 ms Static (Line) Pressure Effects: None ELECTRICAL SPECIFICATIONS Output Signal (Current): 4-20 mA (3 Wire): 15-27 Vdc 80 mA Output Signal (Voltage): 1-5 Vdc (3 wire): 11-27 Vdc 60 mA Rangeablility/ Adjustment: Zero: −5% to 105% of span Span: –5% to 105% of span (Accuracy based upon F.S. (URL) value) Switch Contacts: (2) Photo M0S relay outputs; Load 200 mA (Max.),
40 Vdc; Hysteresis (variable)
All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Trust the Shield® are trademarks of Ashcroft Inc. For more information, see Ashcroft Brands & Trademarks PHYSICAL SPECIFICATIONS Weight: Approx. 1.0 lb Environmental Rating: IP66 Mounting: (2) 5.2 mm mounting holes Pressure Connection: 1/8 NPT Female Electrical Connection Size: ½ NPT Female Conduit Cable Gland (Cable diameters 0.16˝ to 0.63˝) OPTIONAL FEATURES Calibration Report: Traceable calibration certificate TWO POLYSILICON THIN FILM SENSORS WETTED MATERIAL Diaphragm Process Connection Media Compatibility 17-4PH SS 304 SS Fluids and gases compatible with
304 SS (sensor housing) and
17-4PH® SS (sensor diaphragm) NON-WETTED Enclosure Aluminum ORDERING CODE Example: GC55 7 F01 15 CG 75# -XRH Model GC55 - wet/wet indicating differential transducer w/ switch outputs GC55 Accuracy 7 - ±0.5% of span 7 Pressure Fitting F01 - 1/8 NPT Female F01 Output Signal 15 - 1-5 Vdc 15 42 - 4-20 mA Electrical Connection CG - Cable gland CG CD - ½ NPT Female conduit Pressure Range Differential 75# - 75 psi 75# 100# - 100 psi 150# - 150 psi 250# - 250 psi 300# - 300 psi Option (if including an option(s) must include an “X’’) X__ RH - Traceable calibration certificate RH P Building Head LH P2 P1 Pressure drop accross filtration system to monitor clogging. Hydronic flow systems DP measurement of pump head Pump P2 P1 Filter Filter P F P Building Head LH P2 P1 Pressure drop accross filtration system to monitor clogging. Hydronic flow systems DP measurement of pump head Pump P2 P1 Filter Filter P F Fully welded assembly of all stainless steel with high overpressure capability makes the GC55 ideal for fluid pump systems in applications such as:
- Level measurement in large size and/or pressurized tanks
- Pump monitoring of building hydronic heating and cooling systems
- Filter monitoring in water purification or hydraulic systems
All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Trust the Shield® are trademarks of Ashcroft Inc. For more information, see Ashcroft Brands & Trademarks MOUNTING DIMENSIONS MPa OUT1 OUT2 SEL 2.76 3.94 1.18 H(P1) 1.57 L(P2) NPTF Pressure inlet on low-pressure side Pressure inlet on high-pressure side GC55 Differential Pressure Transducer 0.63 0.79 NPTF0.20 0.83 Electrical Connection PG 9 threaded housing, factory installed options include cable gland or ½ NPTF conduit connection 3.46 1.65 Ø 0.20 Mounting holes (2) MOUNTING Note: (2) Mounting holes through back of enclosure, accessible with cover removed. ELECTRICAL CONNECTIONS Power supply (ʵ) Power supply (ʴ) Cable Gland or ½ NPTF Conduit Connection COM. (Switch) OUT 2 (Switch) OUT 1 (Switch) Analog output V A 4-20 mA out 1-5 Vdc out 1/8 1/8 DIMENSIONS in [ ] are millimeters For reference only, consult Ashcroft for specific dimensional drawings