GB60S SLPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 7
Technical content
Features
/square4 2” x 3” x 1.0” Package /square4 For 1U Applications /square4 60W convection cooled /square4 Universal Input 90-264Vac /square4 Optional Power ON LED /square4 Approved to CSA/EN/IEC/UL60950-1, 2nd Edition /square4 Level V Efficiency Compliant Models /square4 Less than 0.5W no-load Power Consumption /square4 3 Year Warranty /square4 RoHS Compliant
Description
The GB60S Series models provide a highly reliable power source in high density 2” x 3” x 1.0” package. Fully compliant to the applicable safety and EMC standards, these models will allow easy integration into many industrial and ITE applications. All 4 models are CE marked to low voltage directive and approved to ITE standards of EN60950, 2nd edition. Model Selection Model Output Current Output Power Ripple & Total OVP Number * Volts Convection Cooled Convection Cooled Noise* * Regulation Threshold GB60S12K 12V 4.58A 55W 120mV pk-pk ±2% 14.4-18Vdc GB60S15K 15V 4.00A 60W 150mV pk-pk ±2% 18-22.5Vdc GB60S24K 24V 2.50A 60W 240mV pk-pk ±2% 28.8-36Vdc GB60S36K 36V 1.67A 60W 360mV pk-pk ±± ±±2% 43.2-54Vdc GB60S48K 48V 1.25A 60W 480mV pk-pk ±2% 57.6-72Vdc Notes: * Models with 24V or higher output voltage meet efficiency requirements of Level V ** Measured with noise probe directly across output terminals, and load terminated with 0.1 µF ceramic and 10 µF low ESR capacitors. At -20C, the noise and ripple is 2% of the output. General Specifications AC Input 100-240Vac, 47-63Hz, 1 ∅ rated 80–270Vac, 47-440Hz operational Turn On Time 2 sec. max. @120Vac Input Current 120Vac: 1.4A, 240Vac: 0.75A Hold-up Time 16mS min. @ 60W load, 120Vac input Inrush Current 240Vac, cold start: will not exceed 40A Signals Optional Power ON LED Input Fuses 4A, 250VAC fuse provided on all models Overload Protection Hiccup Mode, 120% to 180%, typical
www.slpower.com GB60S 18-DEC-14 2 General Specifications (continued) Earth Leakage Current <1mA@240Vac, NC Short Circuit Protection Hiccup Mode Power Factor Not Applicable Overtemperature Protection Self-recovering Efficiency 88% typical (83% for 12V& 85% for 15V) Safety Standards CSA/EN/IEC/UL60950-1, 2 nd Edition. See below for detailed standards information. Output Power 60W continuous (55W for 12V models) Isolation Input-Output: 4000Vac Input-Ground: 1800Vac Output-Ground: 500Vac Peak Output Power Not Applicable Operating Temperature -40C start up. -20C to 80C with derating specified in Fig.1 Ripple and Noise See chart above Output Power Derating See Fig.1 on page 4 Output Voltage See chart Storage Temperature -40° C to +85° C Voltage Adjustability Fixed Relative Humidity 5% to 95%, non-condensing Minimum Load Not required Altitude Operating: 3000 meters Non-operating: 40,000 ft. Total Regulation +/- 2%. See chart MTBF Over 600,000 hours per Telcordia Transient Response 500µS max. to 1%, 50% load step. 0.2A/µS, 3.5% deviation typical Vibration Random Vibration per MIL-STD-810E, Method 514.4, Cat. 1, Figure 514.4.1, 1 hour in each of 3 axes. Switching Frequency 65kHz, typical Shock Half-sine, 40 gpk, 10 mS duration, +/- in each of 3 axes, 6 shocks total Dimensions 2.0” x 3.0” x 1.0” 50.8 x 76.2 x 25.4mm Weight 126g Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±.02”. 3. Mounting holes should be connected together for EMI purpose 4. FG is safety ground connection 5. Specifications are for convection rating at factory settings with 115Vac input and 25° C ambient unless otherwise stated. 6. This power supply requires mounting on metal standoffs 0.20” (5mm) in height.
www.slpower.com GB60S 18-DEC-14 3 EMI/EMC Compliance Conducted Emissions EN55011/22 Class B, FCC Part 15 Class B Radiated Emissions EN55011/22 Class A, FCC Part 15 Class A with 6dB margin Static Discharge Immunity EN61000-4-2, 6kV Contact Discharge, 8kV air discharge Radiated RF Immunity EN61000-4-3, 3V/m EFT/Burst Immunity EN61000-4-4, 2kV/5kHz Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode Conducted RF Immunity EN61000-4-6, 3Vrms Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m Voltage Dip Immunity EN61000-4-11 100Vac, 95% dip/0.5 cycle (Criteria A), 60%/5cycles (Criteria B), 30%/25 cycles (Criteria A). Line Harmonic Emissions EN61000-3-2 Class A Flicker Test EN61000-3-3, Complies (dmax<6%) Mechanical Drawing Connector Information Input Connector J100 DC Output Connector J2 Ground PIN 1) AC LINE PIN 2) EMPTY PIN 3) AC NEUTRAL PIN 1) +Vout PIN 3) -Vout PIN 2) +Vout PIN 4) -Vout 19-30258-0187 (Keystone 1285)(Zierick 895)(.187*0.020) Mating Connector: Tyco/AMP 640250- Pins = 770461-1 Mating Connector: AMP 640250-4 Pins = 770461-1 Molex 01-90020005
www.slpower.com GB60S 18-DEC-14 4 70.0% 80.0% 90.0% 100.0% Efficiency (%) Output Power (W) Efficiency vs. Output Power 120Vac 240Vac Characteristic Curves Output vs. Temperature -40C start up. At -20C, the supply meet its full spec except ripple & noise might be increased from 1% to 2% of the output voltage 55W convection cooled, derating output power to 30W at 70 °C for outputs 12V and 15V 60W convection cooled, derating output power to 50W at 60 °C and 40W at 70 °C for Output Voltages ≥ 24V 20W convection cooled at 80C Fig.1 Efficiency vs. Loading Fig.2 -10 Output Power(W) Temperature ( °°°°C) Output Power vs . Temperature Convection for 12V Model
www.slpower.com GB60S 18-DEC-14 5 Ripple & Noise To verify that the output ripple and noise does not exceed the level specified in the product specification, measured using a scope probe socket with 0.1uF ceramic and a 10uF electrolytic capacitor connected in parallel across it, 20MHz BW. 24V OUT , NO LOAD , 90V AC , 60H Z 24V OUT , FULL LOAD , 90V AC , 60H Z 24V OUT , NO LOAD , 264VAC , 50H Z 24V OUT , FULL LOAD , 264VAC , 50H Z
www.slpower.com GB60S 18-DEC-14 6 Output Transient Response 50% load step within the regulation limits of minimum and maximum load, dI/dt< 0.2A/ µSec. Recovery time not specified as there is no laps in regulation with a 50% Load Step. Maximum voltage deviation is 3.5% 24V OUT , 120V AC , 25% TO 75% LOAD STEP 24V OUT , 240V AC , 25% TO 75% LOAD STEP Output Overload Characteristic 24V OUT , 90V AC 24V OUT , 264V AC Short Circuit Protection Supply shall protect itself against Short Circuit conditions. No damage will occur if the output is shorted. 24V OUT , 90V AC 24V OUT , 264V AC
www.slpower.com GB60S 18-DEC-14 7 Overvoltage Protection OVP firing reduces output voltage to <50% of nominal in <50ms. See models chart for trip ranges. 24V OUT , FULL LOAD , 90VAC , 60H Z 24V OUT , FULL LOAD , 264VAC , 50H Z Turn On Time 24V OUT , FULL LOAD , 90VAC , 60H Z 24V OUT , FULL LOAD , 264VAC , 50H Z Hold Up Time 24V OUT , FULL LOAD , 120VAC , 60H Z Data Sheet © 2014 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice .