GA003 YUANDEAN | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
FEATURES: AC/DC Power Module Universal Input 90~264VAC High Efficiency Up To 82% Protection: Short Circuit /Overload 3 Years Warranty ROHS Compliant AC-DC Converter GA/B/C003 SERIES 3Watt 3KV Isolated Single Output Module Specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified Part Number Output Wattage Output Volatge Output Current Efficiency (W) Vdc mA %(TYP) GX003-S03 2.64 3.3 800 70 GX003-S05 3.0 5 600 72 GX003-S06 3.0 6 500 72 GX003-S07 3.0 7 425 72 GX003-S08 3.0 8 375 75 GX003-S09 3.0 9 333 75 GX003-S10 3.0 10 300 78 GX003-S12 3.0 12 250 78 GX003-S13 3.0 13 230 78 GX003-S14 3.0 14 215 78 GX003-S15 3.0 15 200 79 GX003-S16 3.2 16 200 79 GX003-S18 3.0 18 167 80 GX003-S24 3.0 24 125 80 GX003-S27 3.0 27 110 80 GX003-S36 3.0 36 83 82 GX003-S48 3.0 48 62.5 82 YUAN DEAN SCIENTIFIC YUAN DEAN SCIENTIFIC CO.,LTD Rev:o 2017/5/2 GA/B/C003 SERIES Input Specifications Parameters Conditions Min Typ Max Units Rated input voltage Vo,Io nom 100-240 VAC Input voltage range Vo,Io nom AC in 90 264 VAC DC in 120 370 VDC Line frequency Vi nom.Io nom 47 50/60 63 Hz Inrush current Io nom Vi:115VAC 10 A Vi:230VAC 18 A GA003 GB003 GC003 Notes: ”X” Represent module version A: Represent unit with potting within a plasitc enclosure; B: Represent unit with open frame version without enclosure; C: Represent unit with potting within a plasitc enclosure wired;
Parameters Conditions Min Typ Max Units Voltage accuracy For external circuit please refer to recommended circuit ±1 ±3 % Minimun load Vi nom 0 % Line regulation Io nom, Vi min…Vi max ±1 % Load regulation Vi nom, Io min…Io nom ±2 % Transient recovery time Vi nom,Io nom=I←→0.5Io nom 300 uS Ripple & noise Vi nom,Io nom, BW=20MHz (Tested as Figure2) 100 mVp-p Efficiency Vi nom,Io nom,Po/Pi Up to 82%, See models list Part Number GA/B/C003 SERIES YUAN DEAN SCIENTIFIC CO.,LTD Rev:o 2017/5/2 Temperature Derating Graph General Specifications Parameters Conditions Min Typ Max Units Switching frequency Vi nom,Io nom 65 KHz Isolation voltage Input / output 3.0KVac/ 5mA/5Secs Isolation resistance Input / output,@500Vdc 100 MΩ Ambient temperature Operating at Vi nom,Io nom -20 +70 ℃ Derating Vi nom,Io nom+51 to 71℃ 2 %/℃ Case temperature Operating at Vi nom,Io nom +85 ℃ Storage temperature Nom operational -40 +85 ℃ Relative humidity Vi nom,Io nom 95 % RH Dimension GA003/GC003 L35.05 x W25.40 x H17.78, GB003 L32.5 x W23.0 x H16.0 mm Cooling Free air convection Case material DAP UL 94V-0 Weight GA003/GB003/GC003 30g/12g/32g G X 003 - S 05 A B C D E A:Series B:PackageA,B,C C:Output Watt D:Single(S) E:Output Voltage Ambient Temperature(℃) 100 OutPut Power(%) -20 50 70 Nature Convection Ripple Testing Demonstration AC-DC L N Fuse (+Vo) (-Vo) C5 C6 Load Copper sheet 25.4mm 25.4mm Connect Oscillograph Probe Figure 2
GA003/GB003 L N NC -Vout +Vout +Vin(DC) -Vin(DC) GC003 L(White) N(Black) -Vout(Blue) +Vout(Red) Typical Application Circuit Rev:o 2017/5/2 GA/B/C003 SERIES YUAN DEAN SCIENTIFIC CO.,LTD Figure 1 Typical Application Guide AC/DC application 1. Recommended circuit: Typical application circuit is shown as Figure 1. If EMC performance is not required, Circuit in frame of dashed line can be removed. 2. Clearance and creepage: for application Environment of Class I and Class II devices, users should guarantee there is clearance no less than 2mm and creepage no less than 2.5mm between L and N before the fuse. 3. Fuse, 1A/250V or 10Ω/2W wire-wound resistor. 4. Input filtering capacitor. Terminals 22 and 26 are internal rectification and filtering terminals. To protect the models further, it is recommended to connect an electrolytic capacitor C4 (it is recommended to be 4.7uF/400V). If operation voltage of the module is between 160~264VAC, C4 can be removed. 5. Input EMI filtering network.(Refer to Figure1) Combination of NF, C1, C2 and C3 form input EMI filtering network. MOV: pressure sensitive resistor, model 471KD07 C1: X2 capacitor, recommended parameter 0.1uF/275V CY: 102K/400V (Y1 CAP) NF: common model choke, UU9.8 or ring core, inductance is about 10mH, wire diameter 0.22mm. 6. Output filtering capacitor C5 is electrolytic capacitor. To make sure the product work at perfect operation status with full loading external capacitor is necessary and it is recommended to use high frequency low resistance electrolytic capacitor. C5 rated voltage must be 1.2 times greater than output voltage. Please refer to manufacturer’s datasheet for capacitance and current parameters. 7. “Z” is a TVS to protect post circuits (when module works incorrectly), is recommended. 8. Refer to ripple testing demonstration,C6 is recommended to be 0.1uF. Markings and dimensions Bottom View 1 3 13 26 22 16 14 Front View 35.05TYP 17.78TYP 1.00 0.05 17.78 30.48 5.08 25.40TYP 6.00TYP 2.03 TOP View 1 3 26 22 16 14 17.78 30.48 5.08 1.0 1.8 3.8 4.4 16.0MAX 1.0 23.0TYP 32.5TYP - + ~ ~ GA003 GB003 100TYP 100TYP 5.0TYP 5.0TYP Bottom View 1 3 16 14 Front View 35.05TYP 17.78TYP 17.78 30.48 5.08 25.40TYP 2.03 5.08 GC003 UNIT:mm Unless otherwise specified, all tolerances are ±0.50 Application Note 1. Please make sure all terminals are connected in accordance with instruction manual. 2. The module is a sort of electronic components, installing and using should be implemented by professionals. 3. This series of power module is a sort of first level power supply, safety standard must be strictly abided in application. 4. Make sure the input of module is connected with a fuse, to meet the requirement of safety standard. The parameters of fuse should be appropriate. 5. The input and output of module are dangerous energies, and it must be guaranteed that end users will not be able to touch them. 6. Application circuits and parameters are for reference only. They should be confirmed by experiment before finish a circuit design. 7. You may not be noticed for amendments and updated of this document. Please pay attention on new application in actual application. 8. This product can not be used in parallel and can not support hot-plug.