G S G6S Surface-mounting Relay Compact, Industry-Standard 2-pole relay, designed to switch 2A Signal Loads.
- Long terminals for ideal for soldering and mounting reliability. (Surface mounting terminal models)
- Space-saving inside-L terminal. (Surface mounting terminal models)
- Unique terminal structure, designed to withstand IRS soldering processes. (Surface mounting terminal models)
- High dielectric strength (2,000 VAC) and impulse withstand voltage between coil and contacts (2,500 V, 2 × 10 μs: Telcordia requirements).
- Ultra-miniature at 9.4 mm (H) × 7.5 mm (W) × 15 mm (L).
- Models available with BSI (EN62368-1) supplementary insulation certification. (-Y type) ■Model Number Legend ■Ordering Information Surface mounting terminal standard models Note 1. When ordering, add the rated coil voltage to the model number. Example: G6S-2F DC3 However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC. Note 2.When ordering tape packing, add -TR" to the model number. Be sure since -TR" is n ot part of the relay model number, it is not marked on the relay case. Note 3.When ordering tape packing, minimum order unit is 2 reels (400 pcs × 2 = 800 pcs). Note 4.Surface mounting terminal (SMT) standard models are shipped in moisture-proof package. RoHS Compliant Packing Tube Packing Tape Packing Enclosure rating Relay Function Contact form Model Rated coil voltage Minimum packing unit Model Rated coil voltage Minimum packing unit Minimum ordering unit (tape packing) Fully sealed Single-side stable DPDT (2c) G6S-2F G6S-2G
3 VDC
400 pcs/reel 800 pcs/2 reels 4.5 VDC 4.5 VDC
5 VDC 5 VDC
12 VDC 12 VDC
24 VDC 24 VDC
5 VDC
4.5 VDC 4.5 VDC 4.5 VDC 4.5 VDC
- Relay Function None : Single-side stable U : Single-winding latching K : Double-winding latching 2. Number of poles/ Contact form 2: 2-pole/DPDT (2c) G6S @-@@ -@ 12 34 3. Terminal Shape None : PCB terminals F : Outside-L surface mounting terminals G : Inside-L surface mounting terminals 4. Approved Standards None : UL, CSA Y : UL, CSA, BSI (EN62368-1) ■Application Examples
- Telecommunication equipment
- Measurement devices
- Office automation machines
- Audio-visual products.
- Security equipment
- Building automation equipment
- Industrial equipment
- Amusement equipment
- Home appliances Rated coil voltage
G6S Surface-mounting Relay G S
- PCB Terminal Standard Models Note 1. When ordering, add the rated coil voltage to the model number. Example: G6S-2 DC3 However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC. Note 2.PCB terminal standard types do not require moisture proof packaging and therefore shipped in non-moisture-proof package. ■Ratings
- Single-side Stable Model Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2.Operating characteristics are measured at a coil temperature of 23°C. 3.The maximum voltage is the highest voltage that can be imposed on the relay coil.
- Single-winding Latching Model Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2.Operating characteristics are measured at a coil temperature of 23°C. 3.The maximum voltage is the highest voltage that can be imposed on the relay coil.
- Double-winding Latching Model Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2.Operating characteristics are measured at a coil temperature of 23°C. 3.The maximum voltage is the highest voltage that can be imposed on the relay coil. Enclosure rating Relay Function Single-side stable Single-winding latching Double-winding latching Minimum packing unitContact form Model Rated coil voltage Model Rated coil voltage Model Rated coil voltage Fully sealed DPDT (2c) G6S-2
4.5 VDC 4.5 VDC 4.5 VDC
5 VDC 5 VDC 5 VDC
12 VDC 12 VDC 12 VDC
24 VDC 24 VDC 24 VDC
−−12 VDC 12 VDC (mA) Coil resistance (Ω) Must operate voltage (V) Must release voltage (V) Max. voltage (V) Power consumption (mW)Model Rated voltage G6S-2 G6S-2F G6S-2G DC 34 6 . 7 6 4 . 3 75% max. 10% min. 200% (at 23°C) Approx. 1404.5 31 145 5 28.1 178 12 11.7 1,028 24 8.3 2,880 170% (at 23°C) Approx. 200 G6S-2-Y G6S-2F-Y G6S-2G-Y DC 54 0 1 2 5 75% max. 10% min. 170% (at 23°C) Approx. 20012 16.7 720 24 9.6 2,504 Approx. 230 Item Rated current (mA) Coil resistance (Ω) Must operate voltage (V) Must release voltage (V) Max. voltage (V) Power consumption (mW)Model Rated voltage G6SU-2 G6SU-2F G6SU-2G DC 33 3 . 3 9 0 75% max. 75% max. 180% (at 23°C) Approx. 1004.5 22.2 203 52 0 2 5 0 12 8.3 1,440 24 6.3 3,840 Approx. 150 G6SU-2-Y G6SU-2F-Y G6SU-2G-Y DC 5 28.1 178 75% max. 75% max. 200% (at 23°C) Approx. 14012 11.7 1,028 24 5.8 4,114 Item Rated current (mA) Coil resistance (Ω) Must operate voltage (V) Must release voltage (V) Max. voltage (V) Power consumption (mW)Model Rated voltage G6SK-2 G6SK-2F G6SK-2G DC 36 6 . 6 4 5 75% max. 75% max. 170% (at 23°C) Approx. 2004.5 44.4 101 54 0 1 2 5 12 16.7 720 24 12.5 1,920 140% (at 23°C) Approx. 300 Rated coil voltage
- Contacts Item Load Resistive load Contact type Bifurcated crossbar Contact material Ag (Au-Alloy) Rated load 0.5 A at 125 VAC;
2 A at 30 VDC
Max. switching voltage 250 VAC, 220 VDC Max. switching current 2 A
G6S Surface-mounting Relay G S ■Characteristics Note: The above values are initial values. *1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method. *2. The insulation resistance was measured with a 500 VDC megohmmete r applied to the same parts as those used for checking the dielectric strength (except between the set and reset coil). *3. This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary, depending on switching frequency, operating conditions, expected reliability level of the relay, etc. It is always recommended to double-check relay suitability under actual load conditions. ■Engineering Data Item Relay Function Single-side Stable G6S-2, G6S-2F, G6S-2G Single-winding Latching G6SU-2, G6SU-2F, G6SU-2G Double-winding Latching G6SK-2, G6SK-2F, G6SK-2G Single-side Stable G6S-2F-Y, G6S-2G-Y, G6S-2-Y Single-winding Latching G6SU-2-Y, G6SU-2F-Y, G6SU-2G-Y Contact resistance *1 75 mΩ max. Operate (set) time 4 ms max. Release (reset) time 4 ms max. Min. set/reset pulse width − 10 ms − 10 ms Insulation resistance *2 1,000 MΩ min. (at 500 VDC) Dielectric strength Between coil and contacts 2,000 VAC, 50/60 Hz for 1 min 1,000 VAC, 50/60 Hz for 1 min 2,000 VAC, 50/60 Hz for 1 min Between contacts of different polarity 1,500 VAC, 50/60 Hz for 1 min Between contacts of the same polarity 1,000 VAC, 50/60 Hz for 1 min Between set and reset coil − 500 VAC, 50/60 Hz for 1 min − Insulation distance Between coil and contacts Clearance: 1 mm, Creepage: 1.5 mm Clearance: 2 mm, Creepage: 2 mm Impulse withstand voltage Between coil and contacts 2,500 V (2 × 10 μs); 1,500 V (10 × 160 μs) 1,500 V (10 × 160 μs) 2,500 V (2 × 10 μs); 1,500 V (10 × 160 μs) Between contacts of different polarity 2,500 V (2 × 10 μs); 1,500 V (10 × 160 μs) Between contacts of the same polarity 1,500 V (10 × 160 μs) Vibration resistance Destruction 10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude) Malfunction 10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) Shock resistance Destruction 1,000 m/s2 Malfunction 750 m/s2 Durability Mechanical 100,000,000 operations min. (at 36,000 operations/hr) Electrical 100,000 operations min. for AC (at 1,800 operations/h with rated load) 100,000 operations min. for DC (at 1,200 operations/h with rated load) Failure rate (P level) (reference value) *3 10 μA at 10 m VDC Ambient operating temperature -40°C to 85°C (with no icing or condensation), and -40°C to 70°C (with no icing or condensation) only for double-winding latching 24 VDC and -Y type 24 VDC Ambient operating humidity 5% to 85% Weight Approx. 2 g
- Maximum Switching Capacity
- Durability G6S-2F(G)
- Ambient Temperature vs. Maximum Voltage (Single-side Stable)
- Ambient Temperature vs. Maximum Voltage (Latching) Note: “Maximum voltage” is the maximum voltage that can be applied to the Relay coil.
- Ambient Temperature vs. Switching Current (Single-side Stable)
- Ambient Temperature vs. Switching Current (Latching)
- Ambient Temperature vs. Must Operate or Must Release Voltage G6S-2F(G)
- Shock Malfunction G6S-2F(G) Conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with and without energizing the Relays to check the number of contact malfunctions. 10 30 50 70 100 300 500 700 1,000 Switching voltage (V) Switching current (A) 0.1 0.7 0.5 0.3 DC resistive load AC resistive load 500 300 100 0 0.5 1 1.5 2 2.5 3 Switching current (A)
125 VAC resistive load
Ambient temperature 23°C Switching frequency: 1,800 operations/h
30 VDC resistive load
Ambient temperature 23°C Switching frequency: 1,200 operations/h Durability (×104 operations) G6S 4.5 to 12 VDC G6S-Y
24 VDC
12 VDC max. −40 −20 0 20 40 60 80 100 250 200 150 100 Ambient temperature (°C) Maximum voltage (%) 250 200 150 100 G6SU G6SK 12 VDC max. G6SK Maximum voltage (%) −40 −20 0 20 40 60 80 100 250 200 150 100 Ambient temperature (°C) G6S 12 VDC max. G6S 12 VDC max. G6S-Y Switching current (A) 40 50 60 70 80 90 100 Ambient temperature (°C) 40 50 60 70 80 90 100 Ambient temperature (°C) G6SK 24 VDC G6SU 12 VDC max. G6SU 24 VDC G6SK 12 VDC max. Switching current (A) 100 −60 −40 −20 0 20 40 60 80 100 120 Ambient temperature (°C) Sample: G6S-2F Number of Relays: 10 pcs max. X X Must operate voltage Must release voltage min. min. max. On the basis of rated voltage (%) Z Y X 200 400 600 800 1,000 1,000 1,0001,000 1,000 800 600 400 200 1,000 Shock direction Unit: m/s Sample: G6S-2F Number of Relays: 10 pcs XX ' Energized Z Y De- energized
G6S Surface-mounting Relay G S *1. The tests were conducted at an ambient temperature of 23°C. *2. The contact resistance data are periodically measured referenc e values and are not values from each monitoring operation. Contact resistance values will vary according to the switching frequency and operating environment, so be sure to check operation under the actual operating conditions before use. *3. High-frequency characteristics depend on the PCB to which the Re lay is mounted. Always check these characteristics, including durability, in the actual machine before use.
- Electrical Endurance (with Must Operate and Must Release Voltage) *1 G6S-2F(G)
- Electrical Endurance (Contact Resistance) *1 G6S-2F(G)
- Electrical Endurance (with Must Operate and Must Release Voltage) *1 G6S-2F(G)
- Electrical Endurance (Contact Resistance) *1 G6S-2F(G)
- Contact Reliability Test (Contact Resistance) *1, *2 G6S-2F(G)
- Must Operate and Must Release Time Distribution *1 G6S-2F(G)
- Distribution of Bounce Time *1 G6S-2F(G)
- Mutual Magnetic Interference G6S-2F(G)
- External Magnetic Interference G6S-2F(G) (Average value) (Average value) (Average value)
- Mutual Magnetic Interference G6S-2F(G) High-frequency Characteristics (Isolation) *1, *2 G6S-2F(G) (Average value (initial))
- High-frequency Characteristics (Insertion Loss) *1, *3 G6S-2F(G) (Average value (initial))
- High-frequency Characteristics (Return Loss, V.SWR) *1, *3 G6S-2F(G) (Average value (initial)) 100 Must operate voltage Must release voltage Sample: G6S-2F Number of Relays: 10 pcs Measurement conditions: NO contact - wire-spring relay load at 48 VDC, 120mA (with ARC-killer) NC contact - resistive load at 48 VDC, 60mA Switching frequency: 3,600 operations/h min. min. max. max. 50 100 300 500 1,000 5,000 Operating frequency (×103 operations) On the basis of rated voltage (%) NO contact NC contact Contact resistance Sample: G6S-2F Number of Relays: 10 pcs Measurement conditions: NO contact - wire-spring relay load at 48 VDC, 120mA (with ARC-killer) NC contact - resistive load at 48 VDC, 60mA Switching frequency: 3,600 operations/hmax. min. max. min. 1,000 500 300 100 50 100 300 500 1,000 5,000 Operating frequency (×10 3 operations) Contact resistance (mΩ) 1 3 5 10 30 50 100 300 500 Operating frequency (×103 operations) 100 Must operate voltage Must release voltage min. Sample: G6S-2F Number of Relays: 10 pcs Test conditions: 2A resistive load at 30-VDC with an operation rate of 50% Switching frequency: 1,200 operations/h max. min. max. On the basis of rated voltage (%) 1,000 500 300 100 Operating frequency (×103 operations) NO contact NC contact 1 3 5 10 30 50 100 300 500 Contact resistance Sample: G6S-2F Number of Relays: 10 pcs Test conditions: 2A resistive load at 30-VDC with an operation rate of 50% Switching frequency: 1,200 operations/h max. max. min. min. Contact resistance (mΩ) NO contact NC contact 1,000 500 300 100 10 30 50 100 300 500 1,000 10,000 50,000 Sample: G6S-2F Number of Relays: 10 pcs Test conditions: 10 μA resistive load at 10 m VDC with an operation rate of 50% Switching frequency: 7,200 operations/h min. min. max. max. Operating frequency (×103 operations) Contact resistance (mΩ) 0.5 1 1.5 2 2.5 3 Sample: G6S-2F Number of Relays: 50 pcs Time (ms) Number of contacts Must operate time Must release time Number of contacts 0 0.5 1 1.5 2 2.5 3 Sample: G6S-2F Number of Relays: 50 pcs Time (ms) Operating bounce time Release bounce time +30 +20 +10 −10 −20 −30 Average value TestInitial stage +30 +20 +10 −10 −20 −30 Average value TestInitial stage Energized Sample 2.22 mm Sample Not energized Change rate on the basis of initial value (%) Change rate on the basis of initial value (%) Must operate voltage Must release voltage −1,200 −800 −400 0 400 800 1,200 +30 +20 +10 −10 −20 −30 External magnetic field (A/m) Must operate voltage Must release voltage Sample: G6S-2F Number of Relays:10 pcs SNSN Rate of variability (%) −1,200 −800 −400 0 400 800 1,200 +30 +20 +10 −10 −20 −30 External magnetic field (A/m) Must operate voltage Must release voltage Sample: G6S-2F Number of Relays:10 pcs SNSN Rate of variability (%) −1,200 −800 −400 0 400 800 1,200 Rate of variability (%) +30 +20 +10 −10 −20 −30 External magnetic field (A/m) Must operate voltage Must release voltage Sample: G6S-2F Number of Relays:10 pcs SNSN +30 +20 +10 −10 −20 −30 Average value TestInitial stage +30 +20 +10 −10 −20 −30 Average value TestInitial stage Sample 4.64 mm Not energized Energized Sample Must operate voltage Must release voltage Change rate on the basis of initial value (%) Change rate on the basis of initial value (%) Isolation (dB) 10 30 50 100 300 500 1,000 5,000 Frequency (MHz) Sample: G6S-2F Number of Relays: 10 pcs 0.4 0.8 1.2 1.6 2.0 10 30 50 100 300 500 1,000 5,000 Frequency (MHz) Sample: G6S-2F Number of Relays: 10 pcs Insertion loss (dB) 10 30 50 100 300 500 1,000 5,000 Frequency (MHz) Sample: G6S-2F Number of Relays: 10 pcs Return loss (dB) 2.5 2.0 1.5 1.0 0.5 Return loss V.SWR V.SWR
G6S Surface-mounting Relay G S ■Dimensions 5 4 3 1 8 9 1012 9.2±0.2 14.8±0.2 7.3±0.2 0.65 0.5 5.08 2.54 2.54 Orientation mark 9.2+0.5 −0.3 0.25 5.08 2.54 2.54 2.2 8 Single-side Stable G6S-2F G6S-2F-Y Mounting Dimensions (Top View) Tolerance: ±0.1 mm Terminal Arrangement/ Internal Connections (Top View) Note 1. Each value has a tolerance of ±0.3 mm. Note 2.The coplanarity of the terminals is 0.1 mm max. Note: Check carefully the coil polarity of the Relay. 5 4 3 1 8 9 1012 Orientation mark 9.2±0.2 14.8±0.2 7.3±0.2 0.65 0.5 5.08 2.54 2.54 4.9+0.3 −0.5 0.25 5.08 2.54 2.54 2.2 6.1 G6S-2G G6S-2G-Y Mounting Dimensions (Top View) Tolerance: ±0.1 mm Terminal Arrangement/ Internal Connections (Top View) Note 1. Each value has a tolerance of ±0.3 mm. Note 2.The coplanarity of the terminals is 0.1 mm max. Note: Check carefully the coil polarity of the Relay. 8 9 1012 5 4 3 1 2.54 2.54 2.54(1.05) 2.54 5.08 5.08±0.1 (1.11) Eight, 1-dia. holes 9.2±0.2 14.8±0.2 7.3±0.2 0.65 2.95 0.5 5.08 2.54 0.25 5.08 2.54 Orientation mark G6S-2 G6S-2-Y PCB Mounting Holes (Bottom View) Terminal Arrangement/ Internal Connections (Bottom View) Note: Each value has a tolerance of ±0.3 mm. Note: Check carefully the coil polarity of the Relay. 5 4 3 1 8 91012 S R Orientation mark 9.2/unif0b10.2 14.8/unif0b10.2 7.3/unif0b10.2 0.65 0.5 5.08 2.54 2.54 9.2/unif02b0.5 /unif02d0.3 0.25 5.08 2.54 2.54 2.2 8 Single-winding Latching G6SU-2F G6SU-2F-Y Mounting Dimensions (Top View) Tolerance: ±0.1 mm Terminal Arrangement/ Internal Connections (Top View) Note 1. Each value has a tolerance of ±0.3 mm. Note 2.The coplanarity of the terminals is 0.1 mm max. Note: Check carefully the coil polarity of the Relay. 5 4 3 1 8 9 1012 S R Orientation mark 9.2±0.2 14.8±0.2 7.3±0.2 0.65 0.5 5.08 2.54 2.54 4.9+0.3 −0.5 0.25 5.08 2.54 2.54 2.2 6.1 G6SU-2G G6SU-2G-Y Mounting Dimensions (Top View) Tolerance: ±0.1 mm Terminal Arrangement/ Internal Connections (Top View) Note 1. Each value has a tolerance of ±0.3 mm. Note 2.The coplanarity of the terminals is 0.1 mm max. Note: Check carefully the coil polarity of the Relay. 2.54 2.54 2.54(1.05) 2.54 5.08 5.08±0.1 (1.11) Eight, 1-dia. holes 8 9 1012 5 4 3 1 S R 9.2±0.2 14.8±0.2 7.3±0.2 0.65 2.95 0.5 5.08 2.54 0.25 5.08 2.54 Orientation mark G6SU-2 G6SU-2-Y PCB Mounting Holes (Bottom View) Terminal Arrangement/ Internal Connections (Bottom View) Note: Each value has a tolerance of ±0.3 mm. Note: Check carefully the coil polarity of the Relay.
G6S Surface-mounting Relay G S 9.2±0.2 14.8±0.2 7.3±0.2 0.65 0.5 5.08 2.54 2.54 2.54 9.2+0.5 −0.3 0.25 5.08 2.54 2.54 2.54 2.2 8 5 4 3 1 8 9 1012 S R Orientation mark Double-winding Latching G6SK-2F Mounting Dimensions (Top View) Tolerance: ±0.1 mm Terminal Arrangement/ Internal Connections (Top View) Note 1. Each value has a tolerance of ±0.3 mm. Note 2.The coplanarity of the terminals is 0.1 mm max. Note: Check carefully the coil polarity of the Relay. 9.2±0.2 14.8±0.2 0.65 0.5 5.08 2.54 2.54 2.54 0.25 2.54 2.54 7.3±0.2 4.9+0.3 −0.5 0.25 5.08 2.54 2.2 6.1 5 4 3 1 8 9 1012 S R Orientation mark G6SK-2G Mounting Dimensions (Top View) Tolerance: ±0.1 mm Terminal Arrangement/ Internal Connections (Top View) Note 1. Each value has a tolerance of ±0.3 mm. Note 2.The coplanarity of the terminals is 0.1 mm max. Note: Check carefully the coil polarity of the Relay. 8 9 1012 5 4 3 1 S R 2.54 2.54 2.54(1.05) 2.54 2.54 5.08 5.08±0.1 (1.11) Ten, 1-dia. holes 9.2±0.2 14.8±0.2 7.3±0.2 0.65 2.95 0.5 5.08 2.54 0.25 5.08 2.54 2.54 Orientation mark G6SK-2 PCB Mounting Holes (Bottom View) Terminal Arrangement/ Internal Connections (Bottom View) Note: Each value has a tolerance of ±0.3 mm. Note: Check carefully the coil polarity of the Relay.
G6S Surface-mounting Relay G S ■Tube Packing and Tape Packing Surface mounting terminal (SMT) standard models are shipped in moisture-proof package, and PCB terminal standard types do not require moisture proof packaging and therefore shipped in non-moisture-proof package. Please refer to "Correct Use" for handling after opening moisture-proof packaging for Surface mounting terminal (SMT) models. (1) Tube Packing
- Relays in tube packing are arranged so that the orientation mark of each Relay in on the left side. Be sure not to make mistakes in Relay orientation when mounting the Relay to the PCB. Tube length: 772 mm (stopper not included) No. of Relays per tube: 50 pcs (2) Tape Packing (Surface Mounting Terminal Models)
- When ordering Relays in tape packing, add the prefix “-TR” to the model number, otherwise the Relays in tube packing will be provided. Relays per Reel: 400 pcs Minimum packing unit: 2 reels (800 pcs) 1. Direction of Relay Insertion Reel Dimensions 3. Carrie Tape Dimensions Stopper (gray) Orientation of Relays Stopper (green) Top tape (cover tape) Carrier tape Embossed tape Orientation mark Pulling direction 2±0.3 25.5±0.5 29.5±1.0 21±0.5 13±0.2 80 330 1.5+0.1 9.7 16±0.1 1.75±0.1 15.3 15.3 0.4±0.05 9.7±0.1 11.5±0.1 24±0.3 4±0.1 2±0.1 1.5+0.1 7.8 16±0.1 1.75±0.1 0.4±0.05 9.7±0.1 11.5±0.1 24±0.3 4±0.1 2±0.1 G6S-2F(-Y), G6SU-2F, G6SK-2F G6S-2G(-Y), G6SU-2G, G6SK-2G
G6S Surface-mounting Relay G S ■Recommended Soldering Method (1) IRS Method (Mounting Solder: Lead) (2) IRS Method (Mounting Solder: Lead-free)
- The thickness of cream solder to be applied should be within a range between 150 and 200 µm on OMRON’s recommended PCB pattern.
- In order to perform correct soldering, it is recommended that the correct soldering conditions be maintained as shown below on the left side. Visually check that the Relay is properly soldered. ■Approved Standards UL recognized: (File No. E41515) CSA certified: (File No. LR31928) BSI (EN62368-1) (File No.VC657351) (-Y type) ■Precautions
- Please refer to “PCB Relays Common Precautions” for correct use.
- Long-term Continuously ON Contacts
- Using the Relay in a circuit where the Relay will be ON continuously for long periods (without switching) can lead to unstable contacts because the heat generated by the coil itself will affect the insulation, causing a film to develop on the contact surfaces. We recommend using a latching relay (magnetic-holding relay) in this kind of circuit. If a single-side stable model must be used in this kind of circuit, we recommend using a fail-safe circuit design that provides protection against contact failure or coil burnout.
- Relay Handling
- Use the Relay as soon as possible after opening the moistureproof package. (As a guideline, use the Relay within one week at 30°C or less and 60% RH or less.) If the Relay is left for a long time after opening the moisture-proof package, the appearance may suffer and seal failure may occur after the solder mounting process. To store the Relay after opening the moisture-proof package, place it into the original package and sealed the package with adhesive tape.
- When washing the product after soldering the Relay to a PCB, use a water-based solvent or alcohol-based solvent, and keep the solvent temperature to less than 40°C. Do not put the Relay in a cold cleaning bath immediately after soldering.
- Claw Securing Force During Automatic Mounting 150 20 to 30 220 to 240 180 to 200 Soldering Preheating Time (s) 90 to 120 Temperature (°C) (The temperature profile indicates the temperature on the circuit board surface.) 250 max. 230 180 150 Time (s) 120 max. 30 max. Relay terminal section Soldering Preheating Uppwe surface of case (peak): 255°C max. Temperature (°C) (The temperature profile indicates the temperature on the PCB.) Insufficient amount of solder Excessive amount of solder Heel fillet is formed Solder PCB Land Terminal Relay Correct Soldering Inc orrect Soldering Contact form Coil ratings Contact ratings Number of test operations DPDT (2c) 3 to 24 VDC
3 A, 30 VDC at 40°C
0.3 A, 110 VDC at 40°C
0.5 A, 125 VAC at 40°C
6,000 Contact form Isolation category Voltage DPDT (2c) Supplementary Insulation 250 VAC Correct Use
G6S Surface-mounting Relay G S
- During automatic insertion of Relays, be sure to set the securing force of each claw to the following so that the Relay’s characteristics will be maintained. A C B Dimension A: 1.96 N max. Dimension B: 4.90 N max. Dimension C: 1.96 N max. Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. K093-E1-13 0118(0207)(O) Note: Do not use this document to operate the Unit.