G6S-2F-TR-DC5 OMRON | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 12
Technical content
- High dielectric withstand voltage of 2,000 VAC between coil and contacts (standard type); 1,500 VAC between contacts of different polarity. Meets FCC Part 68 and Telcordia 2.5 kV surge withstand. European version certified for EN60950/EN41003 Supple- mentary Insulation at 250 V at Pollution Degree 2. Low power consumption of 140 mW (Non-latching) Available in through-hole and SMT terminals. Tape and reel or tube packaging. RoHS Compliant.
Ordering Information
■Standard Version * Certified for EN60950/EN41003 Supplementary Insulation at 250 V (pollution degree 2) Model Number Legend Terminal Model Contact form Non-latching Single coil latching Dual coil latchingStandard European Version* Gull-wing DPDT G6S-2F G6S-2F-Y G6SU-2F G6SK-2F Inside “L ” G6S-2G G6S-2G-Y G6SU-2G G6SK-2G PCB through-hole G6S-2 G6S-2-Y G6SU-2 G6SK-2 Rated coil voltage Notes: 1. When ordering, add the rated coil voltage to the model number. Example: G6S-2F DC12 2. When ordering tape packing (surface mount models), add "-TR" to the model number. When ordering High-sensitivity dual coil latching models, add "-H” to the model number. Example: G6S-2F-TR DC12 "-TR" is not part of the relay model number. Therefore, it is not marked on the relay case. Tape packing 3. Dual coil latching models are available with a High-sensitivity coil. (140 mW; 200 mW for DC24) Example: G6SK-2G-H-TR DC5 High-sensitivity coil 1. Relay Function None: Non-latching U: Single coil latching K: Dual coil latching 2. Contact Form 2: DPDT 3. Terminal Shape None: Through-hole F: Gull-wing surface mount G: Inside “L ” surface mount 4. Approved Standards None: UL/CSA Y: EN60950/EN41003 (Standard coil models - 5, 12, 24 VDC ) 5. Packaging None: Tube packaging TR: Tape and reel packaging (Surface mount models) 6. Rated Coil Voltage 3, 4.5, 5, 12, 24 VDC G6S - - - DC 4 51 32 6
80 Low Signal Relay G6S
■Contact Data Note: P level: λ60 = 0.1 x 10-6/operation This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary depending on the operating environment. Always double-check relay suitability under actual operating conditions. ■Coil Data G6S - Standard Non-latching (G6S-2F, G6S-2G, G6S-2) G6SU - Standard Single Coil Latching (G6SU-2F, G6SU-2G, G6SU-2) G6SK - Standard Dual Coil Latching (G6SK-2F, G6SK-2G, G6SK-2) G6S - European Version, Non-latching (G6S-2F-Y, G6S-2G-Y, G6S-2-Y) Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. The operating characteristics are measured at a coil temperature of 23°C. 3. Pick-up voltage will vary with temperature. 4. The maximum voltage is the highest voltage that can be imposed on the relay coil. Load Resistive load (cos φ = 1) Rated load 0.5 A at 125 VAC
2 A at 30 VDC
Contact material Ag (Au clad) Max. carry current 2 A Max. operating voltage 250 VAC, 220 VDC Max. operating current 2 A Max. switching capacity 62.5 VA, 60 W Min. permissible load 10 μA, 10 mVDC Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) Pick-up voltage Dropout voltage Maximum voltage Power consumption (mW) % of rated voltage 4.5 31.0 145 5 28.1 178 12 11.7 1,028 24 8.3 2,880 170% max.@ 23 °C Approx. 200 Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) Coil Inductance (H) (ref. value) Set pick-up voltage Reset pick-up voltage Maximum volt- age Power consumption (mW)Armature OFF Armature ON % of rated voltage @ 23°C Approx. 100 4.5 22.2 203 0.27 0.14 5 20.0 250 0.36 0.18 12 8.3 1,440 2.12 1.14 24 6.3 3,840 5.80 3.79 Approx. 150 Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) Coil Inductance (H) (ref. value) Set pick-up voltage Reset pick-up voltage Maximum voltage Power consumption (mW) Set Reset Armature OFF Armature ON Armature OFF Armature ON % of rated voltage @ 23°C Approx. 200 5 40 125 0.14 0.088 0.098 0.16 @ 23°C Approx. 300 Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) Pick-up voltage Dropout voltage Maximum voltage Power consumption (mW) % of rated voltage 12 16.7 720 24 9.6 2,504 Approx. 230
■Characteristics Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method. 2. Values in parentheses are typical values unless otherwise stated. 3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking the dielectric strength (except between the set and reset coil). 4. Data shown are of initial value. ■Characteristic Data Service Life Contact resistance (See note 1) 75 mΩ max. Operate (set) time (See note 2) 4 ms max. (mean value approx. 2.5 ms G6S; 2.0 ms G6SU, G6SK) Release (reset) time (See note 2) 4 ms max. (mean value approx. 1.5 ms G6S; 2.0 ms G6SU, G6SK) Bounce time Approx. 0.5 ms Max. operating frequency Mechanical: 36,000 operations/hr Electrical: 1,800 operations/hr (under rated load) Insulation resistance (See note 3) 1,000 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 minute (G6S, G6SU) between coil and contacts 1,000 VAC, 50/60 Hz for 1 minute (G6SK) between coil and contacts 1,500 VAC, 50/60 Hz for 1 minute between contacts of different poles 1,000 VAC, 50/60 Hz for 1 minute between contacts of same pole
500 VAC, 50/60 Hz for 1 minute between set and reset coils (G6SK)
Surge withstand voltage Conforming to Telcordia specs. 2,500 V (2 x 10 μS) between coil and contacts for G6S and G6SU 2,500 V (2 x 10 μS) between contacts of different poles Conforming to FCC Part 68 1,500 V (10 x 160 μS) between coil and contacts for G6SK 1,500 V (10 x 160 μS) between contacts of same pole Vibration Mechanical durability 10 to 55 Hz; 5 mm double amplitude Malfunction durability 10 to 55 Hz; 3.3 mm double amplitude Shock Mechanical durability 1,000 m/s 2; approx. 100 G Malfunction durability 750 m/s2; approx. 75 G Ambient temperature -40 to +85°C with no icing; -40 to +70°C with no icing (G6SK, DC24 coil) Ambient Humidity 5% to 85% RH Service life Mechanical 100,000,000 operations min. (at 36,000 operations/hour) Electrical 100,000 operations min. (2A@30VDC, resistive; 1,200 ops/hr.) 100,000 operations min. (0.5A@125VAC, resistive) See “Characteristic Data” Weight Approx. 2g 0 0.2 1000 500 300 100 200 1.00.80.60.4 Service life (x106 operations) Resistive load: 10 mA, 10 VDC Ambient temperature: +85˚ Contact resistance (mΩ) 0 0.1 1000 500 300 100 200 0.50.40.30.2 Service life (x106 operations) Resistive load: 100 mA, 28 VDC Ambient temperature: +85˚ Contact resistance (mΩ) 0 0.2 1000 500 300 100 200 1.00.80.60.4 Service life (x106 operations) Resistive load: 100 mA, 50 VDC Ambient temperature: +85˚ Contact resistance (mΩ)
82 Low Signal Relay G6S
Maximum Switching Capacity Single Coil Latching Dual Coil Latching Switching current (A) Switching voltage (V)A m bient temperature (°C) Maximum coil voltage (%) Ambient Temperature vs. Maximum Coil Voltage Non-latching Ambient temperature (°C) Maximum coil voltage (%) G6SU G6SK
12 VDC
max. G6SK
24 VDC
12 VDC max. (G6S-Y , 12 VDC max.) Reference Data Ambient Temperature vs. Switching Current Non-latching Switching current (A) Single Coil Latching Dual Coil Latching Ambient temperature (°C) G6SU 12 VDC max. G6SU 12 VDC max. G6SK Operating current (A) Ambient temperature (°C) 12 VDC max. (G6S-Y) (G6S-Y , 12 VDC max.) (G6S-Y) Note: The maximum coil voltage refers to the maximum value in a varying range of operating po wer voltage, not a continuous voltage. 0 0.4 500 300 100 200 2.01.61.20.8 Rated operating current (A) Service life (x104 operations) 30 VDC
125 VAC
1000 1500 2000 2500 3000 3500 Between coil and contacts Breakdown voltage (V) Number of contacts (pcs.) 1000 1500 2000 2500 3000 3500 Between contacts of same pole. Between contacts of different poles Breakdown voltage (V) Number of contacts (pcs.) Electrical Service Life Dielectric Streng th (Standard Version, Non-latching) Detecting current: 1mA
Impulse Withstand Voltage (Standard Version, Non-latching) Impulse Withstand Voltage (European version) Dielectric Strength (European Version, Non-latching) 3500 4000 4500 5000 5500 6000 Number of contacts (pcs.) Breakdown voltage (V) Between coil and contacts 1500 2000 2500 3000 3500 4000 15Number of contacts (pcs.) Breakdown voltage (V) Between contacts of same pole 3500 4000 4500 5000 5500 6000 Number of contacts (pcs.) Breakdown voltage (V) Between coil and contacts Between contacts of different poles (2 x 10 μs) (10 x 160 μs) (10 x 160 μs) 4000 4500 5000 5500 6000 6500 Number of contacts (pcs.) Breakdown voltage (V) Between coil and contacts Between contacts of different poles 1500 2000 2500 3000 3500 4000 15Number of contacts (pcs.) Breakdown voltage (V) Between contacts of same pole 4000 4500 5000 5500 6000 6500 9Number of contacts (pcs.) Breakdown voltage (V) Between coil and contacts Between contacts of different poles (2 x 10 μs) (10 x 160 μs) (10 x 160 μs) 1500 2000 2500 3000 3500 4000 50Number of contacts (pcs.) Breakdown voltage (V) Between coil and contacts 1500 2000 2500 3000 3500 4000 50Number of contacts (pcs.) Breakdown voltage (V) Between contacts of different poles Between contacts of same pole Detecting current: 1mA
84 Low Signal Relay G6S
Note: 1. All units are in millimeters unless otherwise indicated. 2. Coplanarity is 0.1 mm max. ■Standard Orientation mark G6S-2, G6S-2-Y Tolerance: ±0.3 Footprint (Bottom View) Tolerance: ±0.1 Terminal Arrangement/ Internal Connections (Bottom View) G6S-2G, G6S-2G-Y Tolerance: ±0.3 Footprint (Top View) Tolerance: ±0.1 Terminal Arrangement/ Internal Connections (Top View) Orientation mark G6S-2F, G6S-2F-Y Tolerance: ±0.3 Footprint (Top View) Tolerance: ±0.1 Terminal Arrangement/ Internal Connections (Top View) Eight, 1-dia. holes Orientation mark
■Single Coil Latching G6SU-2 Tolerance: ±0.3 Footprint (Bottom View) Tolerance: ±0.1 Terminal Arrangement/ Internal Connections (Bottom View) G6SU-2G Tolerance: ±0.3 Footprint (Top View) Tolerance: ±0.1 Terminal Arrangement/ Internal Connections (Top View) Orientation mark 7.3+0.2 7.3+0.2 Orientation mark G6SU-2F Tolerance: ±0.3 Footprint (Top View) Tolerance: ±0.1 Terminal Arrangement/ Internal Connections (Top View) Eight, 1-dia. holesOrientation mark
86 Low Signal Relay G6S
■Dual Coil Latching Recommended Soldering Method G6SK-2 Tolerance: ±0.3 Footprint (Bottom View) Tolerance: ±0.1 Terminal Arrangement/ Internal Connections (Bottom View) G6SK-2G Tolerance: ±0.3 Footprint (Top View) Tolerance: ±0.1 Terminal Arrangement/ Internal Connections (Top View) Orientation mark Orientation mark 7.3+0.2 G6SK-2F Tolerance: ±0.3 Footprint (Top View) Tolerance: ±0.1 Terminal Arrangement/ Internal Connections (Top View) Ten, 1-dia. holes Orientation mark (1) IRS Method (Mounting Solder: Lead) Time (s) Temperature (°C) Soldering Preheating (2) IRS Method (Mounting Solder: Lead-free) Temperature (°C) Time (s) 250 max. 230 180 150 Soldering Preheating Preheating Soldering Upper surface of case (peak): 255°C max. 120 max. 30 max. Note: The temperature profile indicates the temperature on the PCB. Relay terminal section 220 to 240 180 to 200 150 90 to 120 20 to 30
■Tape and Reel Dimensions (Surface Mount Models)
- Tape type: TE2416R (Refer to EIAJ - Electronic Industrial Association of Japan) Reel type: R24E (Refer to EIAJ - Electronic Industrial Association of Japan) Relays per reel: 400 Reels per packing carton: 2 (800 relays) ■Approvals UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp. = 40°C EN60950 / EN41003 Note: 1. The rated values approved by each of the safety standards (e.g ., UL and CSA) may be different fr om the performance characterist ics individually defined in this catalog. 2. In the interest of product improvement, specifications are subject to change. Tube packing Standard nomenclature 50 pcs per anti-static tube Tape packing (Surface mount versions) When ordering, add “TR” before the rated coil voltage (e.g., G6S-2F-TR-DC12) Note: TR is not part of the relay model number and will not be marked on the relay. Type Contact form Coil rating Contact ratings Number of test operations G6S-2, G6S-2F , G6S-2G DPDT 2 to 48 VDC 3 A at 30 VDC (Resistive)
0.3 A at 110 VDC (Resistive)
0.5 A at 125 VAC (General Use)
6,000 G6SU-2, G6SU-2F , G6SU-2G G6SK-2, G6SK-2F , G6SK-2G G6SK-2-Y , G6SK-2F-Y , G6SK-2G-Y 2 to 24 VDC Type Contact form Isolation Category Voltage G6S-2-Y , G6S-2F-Y , G6S-2G-Y DPDT Supplementary Isolation 250 VAC G6S-2F, G6SU-2F, G6SK-2F, G6S-2F-Y G6S-2G, G6SU-2G, G6SK-2G, G6S-2G-Y Cover tape Emboss tapeCarrier tape 13±0.2 2±10.5 2±0.3 29.5±1.0 25.5±0.5 R1.0 330 Feed direction Orientation mark
88 Low Signal Relay G6S
Use a DC power supply with 5% or less ripple factor to operate the coil. Do not use the G6S where subject to strong external magnetic fields. Do not use the G6S where subject to magnetic particles or excessive amounts of dust. Do not reverse the polarity of the coil (+, −). Latching types are delivered in t he reset position. We recommend that a reset voltage be applied in advance to start operation. Do not drop the G6S or otherwise subject it to excessive shock. Remove the relay from the packing immediately prior to usage. ■Correct use Long-term Continuously ON Contacts Using the Relay in a circuit wher e the Relay will be ON continuously for long periods (without switching) can lead to unstable contacts because the heat generated by the coil itself will affect the insulation, causing a film to develop on the contact surfaces. We recommend using a latching relay (magnetic-holding relay) in this kind of circuit. If a single-side stable model must be used in this kind of circuit, we rec- ommend using a fail-safe circuit design that provides protection against contact failure or coil burnout. Relay Handling Use the Relay as soon as possible after opening the moisture-proof package. If the Relay is left for a long time after opening the mois- ture-proof package, the appearance may suffer and seal failure may occur after the solder mounting process. To store the Relay after opening the moisture-proof package, pl ace it into the original pack- age and sealed the package with adhesive tape. When washing the product after soldering the Relay to a PCB, use a water-based solvent or alcohol-based solvent, and keep the solvent temperature to less than 40°C. Do not put the Relay in a cold clean- ing bath immediately after soldering. Claw Securing Force During Automatic Mounting During automatic insertion of Relays, be sure to set the securing force of each claw to the following so that the Relay’s characteristics will be maintained. G6S (K) (-U) -2 Soldering Soldering temperature: Approx. 250 °C (At 260 °C if the DWS method is used.) Soldering time: Approx. 5 s max. (Approx. 2 s for the first time and approx. 3 s for the second time if the DWS method is used.) Be sure to adjust the level of the molten solder so that the solder will not overflow onto the PCB. G6S (K) (-U) -2F Soldering The thickness of cream solder to be applied should be within a range between 150 μm and 200 μm on Omron’s recommended PCB pattern. In order to perform correct soldering, it is recommended that the correct soldering conditions be maintained as shown below on the left side. Visually check that the relay is properly soldered. A C B Dimension A: 1.96 N max. Dimension B: 4.90 N max. Dimension C: 1.96 N max. Insufficient amount of solder Excessive amount of solder Heel fillet is formed Solder PCB Land Terminal Relay Correct Soldering Incorrect Soldering
Global - http://www.omron.com USA - http://www.components.omron.com Cat. No. X301-E-1c Printed in USA OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 10/12 Specifications subject to change without notice All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.