G6QE OMRON | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
G Q E G6QE PCB Power Relays Miniature and Low Height Single-pole Power Relay with 36A Switching Current
- High switching current of 36 A@250 VAC and 10,000 operations,
30 A@250 VAC and 100,000 operations in a miniature package
- Achieved 10-kV impulse withstand voltage (between coil and contacts)
- Power consumption reduced to 12% compared with rated coil consumption by lowering the applied voltage to the coil after applying nominal voltage for 100 ms relay operation (Reduced to 35% from rated coil voltage)
- Conforms to cULus, EN and CQC
Ordering Information
Coil Note 1. The rated current and resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. Note 2. The operating characteristics are measured at a coil temperature of 23°C. Note 3. The maximum permissible voltage is the maximum value of the fluctuation range for the Relay coil operating power supply and was measured at an ambient temperature of 23°C. * Power consumption with Holding Voltage is approx.172 mW (when applying Holding Voltage at 35%). Please confirm the detail in p age 3 Coil Voltage Reduction (Holding Voltage). Contacts RoHS Compliant Terminal Shape Classification Contact Form Enclosure rating Model Rated coil voltage Minimum packing unit PCB terminals Standard SPST-NO (1a) Flux protection G6QE-1A
5 VDC
12 VDC
24 VDC
- Home appliances
- FA equipment
- Industrial machinery Model Number Legend G6QE- 1. Number of Poles 1: 1-pole 12 3 3. Enclosure rating None: Flux protection 2. Contact Form A: SPST-NO (1a) Rated Voltage Rated current (mA) Coil resistance (Ω) Must operate voltage (V) Must release voltage (V) Max. voltage (V) Power consumption (mW)% of rated voltage 5 VDC 280 17.9 70% max. 5 to 23% 140% (at 23°C) Approx. 1400 Approx. 172 *12 VDC 116.7 102.9 24 VDC 58.3 411.4 Contact type Single Contact material Ag Alloy (Cd free) Rated load
36 A at 250 VAC (Resistive Load)
32 A at 250 VAC (Resistive Load)
30 A at 250 VAC (Resistive Load)
Max. switching voltage AC 277 V Max. switching current AC: 36 A Note. When ordering, add the rated coil voltage to the model number. Example: G6QE-1A DC12 However, the notation of the coil voltage on the product case as well as on the packing will be marked as VDC. Rated coil voltage
G Q E Characteristics Actual Load Life (Reference Values)
250 VAC Capacitive load
Inrush: 42 A (0-p), Steady: 30A, Break: 2.5 A 150,000 operations min. (Ambient temperature: 23°C) Engineering Data Maximum Switching Capacity Durability Ambient Temperature vs. Maximum Coil Voltage G6QE-1A G6QE-1A G6QE-1A Ambient Temperature vs. Maximum Operate or Must Release Voltage Shock Malfunction G6QE-1A G6QE-1A Contact resistance *1 100 m Ω max. Operate time 20 ms max. Release time 10 ms max. Insulation resistance *2 1000 MΩ min. Dielectric strength Between coil and contacts 4,500 VAC, 50/60 Hz for 1 min Between contacts of the same polarity 2,000 VAC, 50/60 Hz for 1 min Insulation distance Between coil and contacts Clearance: 3.2 mm, Creepage: 6.4 mm Impulse withstand voltage Between coil and contacts 10 kV (1.2 x 50 µs) Vibration resistance Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Shock resistance Destruction 1,000 m/s2 Malfunction 200 m/s2 Durability Mechanical 1,000,000 operations min. (at 18,000 operations/h) Electrical 100,000 operations min. (30 A, 250 VAC, resistive load) 50,000 operations min. (32 A, 250 VAC, resistive load) 10,000 operations min. (36 A, 250 VAC, resistive load) (ON for 1 s and OFF for 9 s) Failure rate (P level) (reference value) *3 100 mA at 5 VDC Coil holding voltage *4 35% to 80% of rated coil voltage (contact carrying current 32 A, at 85 °C) 35% to 50% of rated coil voltage (contact carrying current 36 A, at 85 °C) Ambient operating temperature -40°C to +60°C (when applying Rated Coil Voltage) -40°C to +85°C (contact carrying current 32 A, when applying Holding Voltage at 35% to 80%) (contact carrying current 36 A, when applying Holding Voltage at 35% to 50%) (with no icing or condensation) Ambient operating humidity 5% to 85% Weight Approx. 17 g Note. The values given above are initial values. *1. Measurement conditions: 5 VDC, 1 A, voltage drop method. *2. Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured. *3. This value was measured at a switching frequency of 120 operations/min. *4. Power consumption with Holding Voltage is approx.172 mW (when applying Holding Voltage at 35%). Please confirm the detail in page 3 Coil Voltage Reduction (Holding Voltage). AC resistive load50 1 5 10 50 100 250 500 1,000 100 Switching current (A) Switching voltage (V) 01 02 0 3 0 4 0 500 100 1,000 Contact current (A) Number of operations (×103 operations) 250 VAC, resistive load 180 160 140 120 100 G6QE-1A 32A G6QE-1A 36A Ambient temperature (°C) Maximum coil voltage (%) -40 -20 0 20 40 60 80 100 Connecting Method: Mounted 3 Relays horizontally based on EN Standards Installation Interval: 50 mm Must operate and must release voltage (ratio of rated voltage) (%) Ambient temperature (°C) 100 -60 -40 -20 0 20 40 60 80 100 Sample: G6QE-1A DC12V Number of Relays: 5 pcs Must Operating voltage Must Release voltage Y X Z Y X 1,000 1,000 1,000 1,000 1,000 1,000 200 400 600 600 400 200 800 800 Energized De- energized Shock direction Unit: m/s2 Z Conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with and without energizing the Relays to check the number of contact malfunctions. Standard: 200 m/s 2
G Q E Dimensions Approved Standards The approval rating values for overseas standards are different from the performance values determined individually confirm the values before use. UL/C-UL (CSA) Recognized (File No. E41515) CQC certified: (Certificate No.CQC18002192007) EN/IEC, TÜV Certified: (Certificate No.R50407379) Precautions
- Please refer to "PCB Relays Common Precautions" for correct use. Coil Voltage Reduction (Holding Voltage) after Relay Operation
- If the coil voltage is reduced to the holding voltage after Relay operation, first apply the rated voltage to the coil for at least 100 ms, as shown below.
- A voltage of at least 35% of the rated voltage is required for the coil holding voltage. Do not allow voltage fluctuations to cause the coil holding voltage to fall below this level. * The coil resistance were measured at a coil temperature of 23°C with tolerances of ± 10%. Other Precautions
- This Relay is suitable for power load switching of air- conditioning compressors and power supplies, etc. Do not use this Relay to switch micro loads less than 100 mA, such as in signal applications. 4 3 2120.5 MAX. 3.52-1.5 16 MAX. 2-0.6 SQUARE 2-0.8 30.5 MAX. 6.25±0.1 5.75±0.1 22±0.1 12±0.05 27.6±0.1 2-1.8+0.1 dia. 2-1.3+0.1 dia. G6QE-1A PCB Mounting Holes (BOTTOM VIEW) Terminal Arrangement/ Internal Connections (BOTTOM VIEW) (No coil polarity) Model Coil ratings Contact ratings Number of test operations G6QE-1A 5 to 24 VDC 36 A 277 VAC (Resistive) 85°C 10,000 G6QE-1A 5 to 24 VDC 32 A 277 VAC (Resistive) 40°C 50,000 G6QE-1A 5 to 24 VDC 30 A 277 VAC (Resistive) 40°C 100,000 Model Coil ratings Contact ratings Number of test operations G6QE-1A 5, 12, 24 VDC 36 A 277 VAC (Resistive) 85°C 10,000 G6QE-1A 5, 12, 24 VDC 32 A 277 VAC (Resistive) 40°C 50,000 G6QE-1A 5, 12, 24 VDC 30 A 277 VAC (Resistive) 40°C 100,000 Model Coil ratings Contact ratings Number of test operations G6QE-1A 5, 12, 24 VDC 36 A 277 VAC (cos φ=1) 85°C 10,000 G6QE-1A 5, 12, 24 VDC 32 A 277 VAC (cos φ=1) 40°C 50,000 G6QE-1A 5, 12, 24 VDC 30 A 277 VAC (cos φ=1) 40°C 100,000 Correct Use Applied coil voltage Coil resistance* Power consumption Rated voltage 100% 17.9 Ω (5 VDC) 102.9Ω (12 VDC) 411.4Ω (24 VDC) Approx.1400 mW Holding voltage 35% Approx.172 mW 35% (Holding voltage) 100% (Rated voltage) 100ms min.
Please check each region's Terms & Conditions by region website. OMRON Corporation Electronic and Mechanical Components Company Regional Contact Cat. No. K312-E1-04 0219 (0718)(O) Americas Europe Asia-Pacific China Korea Japan In the interest of product improvement, specifications are subject to change without notice. © OMRON Corporation 2018 All Rights Reserved.