G6J-2FS-Y-TRDC45 OMRON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 12

Technical content

Surface-mounting Relay G6J-Y 43 Surface-mounting Relay G6J-Y Ultra-compact and Slim DPDT Relay

  • Dimensions of 9H x 5.7W x 10.6L mm provide a mounting area reduction of approx. 56% when compared with the OMRON G6S.  Dielectric strength of 1,500 VAC and an impulse withstand voltage of 2,500 V for 2 x 10 μs (conforms to Telcordia specifications (formerly Bellcore)).  Conforms to FCC Part 68 requirments (1,500 V,10 x 160 μs).  Single-winding latching models to save energy.  UL recognized / CSA certified.  RoHS Compliant.

Ordering Information

Model Number Legend: Application Examples Communications equipment, measurement devices, computer peripheral devices, office automation equipment, and audio-visual products. Item Model Terminal Contact form Non-latching Single coil latching PCB through-hole DPDT G6J-2P-Y G6JU-2P-Y SMT Gull-wing G6J-2FL-Y G6JU-2FL-Y SMT Shortened leads G6J-2FS-Y G6JU-2FS-Y Rated coil voltage Note 1: When ordering, add the rated coil voltage to the model number. Example: G6J-2P-Y DC12 Rated coil voltage Note 2: When ordering tape packing, add “-TR” to the model number. “-TR” is not part of the relay model number. Therefore it is not marked on the relay case. Example: G6J-2P-Y -TR DC12 1. Relay Function None: Non-latching, standard U: Single-winding latching 2. Contact Form 2: DPDT 3. Terminal Shape P: PCB through-hole terminals FL: SMT Gull-wing FS: SMT shortened leads 4. Packaging None: Tube packaging TR: Tape and reel packaging 9. Rated Coil Voltage 3, 4.5, 5, 12, 24 G6J - - Y - DC 2 3 4 51

44 Surface-mounting Relay G6J-Y

■Contact Data Note: This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 5% of the load impedance. This value may vary depending on the operating frequency, operating conditions, expected reliability level of the relay, etc. Always double- check relay suitability under actual load conditions. ■Coil Data G6J-Y Standard, Non-latching (G6J-2P-Y, G6J-2FS-Y, G6J-2FL-Y) Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. The operating characteristics are measured at a coil temperature of 23°C. 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously. G6JU-Y Single coil, Latching (G6JU-2P-Y, G6JU-2FL-Y, G6JU-2FS-Y) Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. The operating characteristics are measured at a coil temperature of 23°C. 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously. Rated load 0.3 A @ 125 VAC

1 A @ 30 VDC

Contact material Ag (Au Clad) Max. carry current 1 A Max. operating voltage 125 VAC, 110 VDC Max. operating current 1 A Max. switching capacity 37.5 VA, 30 W Min. permissible load (see note) 10m VDC, 10μA Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) Pick-up voltage Drop-out voltage Max. voltage Power consumption (mW) % of rated voltage 4.5 32.6 137.9 5 28.9 173.1 12 12.3 976.8 24 9.2 2,600.5 230 Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) Set voltage Reset voltage Max. voltage Power consumption (mW)% of rated voltage 4.5 22.0 204.3 5 20.4 245.5 12 9.0 1,329.2

Surface-mounting Relay G6J-Y 45 ■Characteristics Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method. 2. Values in parentheses are typical values unless otherwise stated. 3. The insulation resistance was measured with a 500-VDC Megger Tester applied to the same parts as those for checking the dielectric strength. 4. The above values are initial values. Item Standard non-latching relays Single coil latching relays G6J-2P-Y, G6J-2FS-Y, G6J-2FL-Y G6JU-2P-Y, G6JU-2FS-Y, G6JU-2FL-Y Contact resistance (See note 1) 100 mΩ max. Operating (set) time (See note 2) 3 ms max. (approx. 1.6 ms) Minimum set/reset pulse width --- 10 ms min. (at 100% rated coil voltage) Insulation resistance (See note 3) 1,000 MΩ min. (at 500 VDC) Dielectric strength 1,500 VAC, 50/60 Hz for 1 min. between coil and contacts 1,000 VAC, 50/60 Hz for 1 min. between contacts of different polarity 750 VAC, 50/60 Hz for 1 min. between contacts of the same polarity Surge withstand voltage 2,500 VAC, (2 x 10 μs) between coil and contacts 1,500 VAC, (10 x 160 μs) between contacts of the same and different polarity Vibration Mechanical durability 10 to 55 Hz, 5-mm double amplitude Malfunction durability 10 to 55 Hz, 3.3-mm double amplitude Shock Mechanical durability 1,000 m/s2 (approx. 100G) Malfunction durability 750 m/s2 (approx. 75G) Service life Mechanical 50,000,000 operations min. (at 36,000 operations/hour) Electrical 100,000 operations min. (with a rated load at 1,800 operations/hour) Ambient temperature −40 to 85°C with no icing or condensation Humidity 5% to 85% RH Weight Approx. 1.0 g

46 Surface-mounting Relay G6J-Y

Switching voltage (V) Switching current (A) 0.1 1 3 5 10 30 50 100 300 500 1,000 0.7 0.5 0.3 AC resistive load DC resistive load Ambient temperature (°C) −40 −20 0 20 40 60 80 100 250 200 150 100 Maximum voltage (%) −40 −20 0 20 40 60 80 100 1.2 0.8 0.6 0.4 0.2 Ambient temperature (°C) Switching current (A) Maximum Switching Capacity Ambient Temperature vs. Maximum Voltage Ambient Temperature vs. Switching Current Note: “Maximum voltage” is the maximum voltage that can be applied to the Relay coil. 1,000 500 300 100 Switching current (A)

30 VDC resistive load

Ambient temperature: 23°C Switching frequency: 1,800 operations/hour

125 VAC resistive load

Ambient temperature: 23°C Switching frequency: 1,800 operations/hour Switching operations (x104 operations) max. avg. min. avg. min. max. Maximum estimated value 100 −60 −40 −20 0 20 40 60 80 100 Ambient temperature (°C Operating voltage Release voltage Change rate on the basis of rated voltage (%) Z Y X 200 400 600 800 1,000 1,000 1,0001,000 1,000 800 600 400 200 1,000 Shock directions Unit: m/s Sample: G6J-2P-Y Number of Relays: 10 XX ' Not energized Energized Z Y Electrical Life Expectancy Ambient Temperature vs. Must Operate or Must Release Voltage Shock Malfunction Conditions: Shock is applied in ±X, ±Y , and ±Z directions three times each with and without energizing the Relays to check the number of contact malfunctions. 0.001 0.01 0.1 1 10 100 1,000 Operating frequency (x103 operations) 100 max. min. max. min. Release voltage Operate voltage On the basis of rated voltage (%) Sample: G6J-2P-Y Number of Relays: 10 Test conditions: 1-A resistive load at

30 VDC with an operation rate of 50%

Switching frequency: 1,800 operations/hour Operating frequency (x103 operations) Contact resistance (mΩ) 0.001 0.01 0.1 1 10 100 1,000 NO contact NC contact 1,000 500 300 100 max. min. min. max. Contact resistance Sample: G6J-2P-Y Number of Relays: 10 Test conditions: 1-A resistive load at 30 VDC with an operation rate of 50% Switching frequency: 1,800 operations/hour Operating frequency (x105 operations) Contact resistance (mΩ) 0.001 0.01 0.1 1 10 100 1,000 1,000 500 300 100 max. min. min. max. Sample: G6J-2P-Y Number of Relays: 10 Test conditions: 10 μA resistive load at 10 m VDC with an operation rate of 50% Switching frequency: 7,200 operations/hour Contact resistance NO contact NC contact Electrical Life Expectancy (with Must Operate and Must Release Voltage) (See note.) Electrical Life Expectancy (Contact resistance) (See note.) Contact Reliability Test (See note.) Note: 1. The tests were conducted at an ambient temperature of 23°C. 2. The contact resistance data are periodically measured reference values and are not values from each monitoring operation. Contact resistance values will vary according to the switching frequency and operating environment, so be sure to check operation under the actual operating conditions before use

Surface-mounting Relay G6J-Y 47 Set voltage Reset voltage Installed in flush configuration Initial stage +30 +20 +10 −10 −20 −30 Average value +30 +20 +10 −10 −20 −30 Energized Sample Not energized Sample Change rate on the basis of initial value (%) Change rate on the basis of initial value (%) Installed in flush configuration Initial stage Average value +30 +20 +10 −10 −20 −30 +30 +20 +10 −10 −20 −30 Change rate on the basis of initial value (%) Change rate on the basis of initial value (%) Not energized Energized Sample Sample Set voltage Reset voltage Installed in flush configuration Initial stage Average value Installed in flush configuration Initial stage Average value Mutual Magnetic Interference Mutual Magnetic Interference −1,200 −800 −400 0 400 800 1,200 Change rate on the basis of initial value (%) +30 +20 +10 −10 −20 −30 External magnetic field (A/m) Average value Sample: G6J-2P-Y Number of Relays: 5 SN Must Operate voltage Must Release voltage Change rate on the basis of initial value (%) +30 +20 +10 −10 −20 −30 External magnetic field (A/m) Average value −1,200 −800 −400 0 400 800 1,200 SN Sample: G6J-2P-Y Number of Relays: 5 Must Operate voltage Must Release voltage Change rate on the basis of initial value (%) +30 +20 +10 −10 −20 −30 External magnetic field (A/m) Average value −1,200 −800 −400 0 400 800 1,200 SN Sample: G6J-2P-Y Number of Relays: 5 Must Operate voltage Must Release voltage Average value 100 1 10 100 1,000 1 pole 2 poles Frequency (MHz) Isolation (dB) Average value Frequency (MHz) Insertion Loss (dB) 0.5 1.5 2.5 1 10 100 1,000 1 pole 2 poles Average value Frequency (MHz) Return loss (dB) 3.5 2.5 1.5 0.5 1 10 100 1,000 1-pole V.SWR 2-pole V.SWR 1-pole return loss 2-pole return loss V.SWR External Magnetic Interference High-frequency Characteristics (Isolation) High-frequency Characteristics (Insertion Loss) High-frequency Characteristics (Return Loss, V.SWR) Note: 1. The tests were conducted at an ambient temperature of 23°C. 2. High-frequency characteristics depend on the PCB to which the Relay is mounted. Always check these characteristics, including endurance, in the actual machine before use.

48 Surface-mounting Relay G6J-Y

0 0.5 1 1.5 2 2.5 3 Time (ms) Sample: G6J-2P-Y Number of Relays: 30 Must Operate time Must Release time Number of contacts Time (ms) Number of contacts 0 0.5 1 1.5 2 2.5 3 Sample: G6J-2P-Y Number of Relays: 30 Must Operate bounce time Must Release bounce time After Change rate on the basis of rated value (%) Initial 5.0 4.0 3.0 2.0 1.0 0.0 −1.0 −2.0 −3.0 −4.0 −5.0 Must Operate voltage Must Release voltage Must Operate and Must Release Time Distribution (See note.) Note: The tests were conducted at an ambient temperature of 23°C. Must Operate and Must Release Bounce Time Distribution (See note.) Vibration Resistance Time (ms) Number of contacts 0 0.5 1 1.5 2 2.5 3 Sample: G6J-2P-Y Number of Relays: 30 Must Operate bounce time Must Release bounce time

Surface-mounting Relay G6J-Y 49 Dimensions Note: All units are in millimeters unless otherwise stated. A tolerance of ±0.3 (±0.01) applies to every dimension in the following drawings unless otherwise stated. 5.710.6 3.5 0.3 1.5 3.2 3.2 5.4 7.6 0.4 0.15 7.6 5.4 3.2 Eight, 0.85-dia. holes (1.25)(1.5) 3.2 12 3 4 87 6 5 SR 12 3 4 87 6 5 5.7 5.7 3.2 10.6 0.41.5 10.0 max. 3.2 5.4 7.6 7.6 5.4 3.2 4.35 0.8 (1.5) 2.35 SR 12 3 4 87 6 5 12 3 4 87 6 5 10.6 0.41.5 10.0 max. 3.2 5.4 7.6 5.7 7.4 3.2 7.6 5.4 3.2 5.2 0.8 (1.5) 3.2 SR 12 3 4 87 6 5 12 3 4 87 6 5 G6J-2P-Y G6JU-2P-Y Mounting Dimensions (Bottom View)* Terminal Arrangement Internal Connections (Bottom View) G6J-2P-Y Orientation mark G6JU-2P-Y Orientation mark G6J-2FS-Y G6JU-2FS-Y Mounting Dimensions (Top View)* Terminal Arrangement/ Internal Connections (Top View) G6J-2FS-Y Orientation mark G6JU-2FS-Y Orientation mark *Tolerance ±0.1 mm *Tolerance ±0.1 mm G6J-2FL-Y G6JU-2FL-Y Mounting Dimensions (Top View)* Terminal Arrangement/ Internal Connections (Top View) G6J-2FL-Y Orientation mark G6JU-2FL-Y Orientation mark*Tolerance ±0.1 mm

50 Surface-mounting Relay G6J-Y

Stick Packing and Tape Packing 1. Stick Packing Relays in stick packing are arranged so that the orientation mark of each Relay is on the left side. Always confirm that the Relays are in the correct orientation when mounting the Relays to the PCBs. Stick length: 555 mm (stopper not included) No. of Relays per stick: 50 2. Tape Packing (Surface-mounting Terminal Relays) When ordering Relays in tape packing, add the prefix “-TR” to the model number, otherwise the Relays in stick packing will be provided. Direction of Relay Insertion Reel Dimensions Carrier Tape Dimensions Tape type: TB2412R (EIAJ (Elect ronic Industrial Association of Japan)) Reel type: R24D (EIAJ (Electroni c Industrial Association of Japan)) Relays per reel: 400 Stopper (gray) Orientation of Relays Stopper (green) Pulling Direction Top tape (cover tape) Carrier tape Embossed tape Pulling direction Orientation mark 25.5±0.5 29.5±1 80330 A 21 dia.2±0.5 13±0.2 dia. ±0.5 Enlarged View of Section A 1.5 dia.+0.1 16±0.1 4±0.12±0.1 6.2±0.1 8.3±0.1 5° max. B BA A A-A Cross Section 24±0.2 11.1±0.1 6.3±0.1 10.2±0.1 0.4±0.051.75±0.1 5° max. 5° max. B-B Cross Section 11.5±0.1 G6J-2FS-Y, G6JU-2FS-Y G6J-2FL-Y, G6JU-2FL-Y 1.5 dia.+0.1 A-A Cross Section 5° max. B-B Cross Section 16±0.1 4±0.1 24±0.2 11.1±0.1 6.3±0.1 10.2±0.1 0.4±0.05 11.5±0.1 1.75±0.12±0.1 7.9±0.1 10±0.1 B BA A 5° max.5° max.

Surface-mounting Relay G6J-Y 51 Recommended Soldering Method IRS Method (for Surface-mounting Terminal Relays) Note: Temperatures are given for the surface of the terminal.

  • The thickness of cream solder to be applied should be between 150 and 200 μm on OMRON's recommended PCB pattern.  In order to perform correct soldering, it is recommended that the correct soldering conditions be maintained as shown below on the left-hand side. Visually check that the Relay is properly soldered. ■Approved Standards UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp. = 40°C Surface of the relay terminal Temperature (°C) 250 max. 230 180

150 Preheating

Time (s) 120 max. 30 max. Soldering Top of cover (Peak): 255°C max. Correct Soldering Relay Ter minal SolderPCB Land Incorrect Soldering Insufficient amount of solder Excessive amount of solder Contact form Coil rating Contact ra ting Number of test operations DPDT G6J-2P-Y , 2FS-Y , 2FL-Y: 3 to 24 VDC G6JU-2P-Y , 2FS-Y , 2FL-Y: 3 to 24 VDC

1 A at 30 VDC (Resistive)

0.5 A at 60 VDC (Resistive)

0.3 A at 125 VAC (General purpose)

52 Surface-mounting Relay G6J-Y

Long Term Current Carrying Under a long-term current carrying without switching, the insulation resistance of the coil goes down gradually due to the heat generated by the coil itself. Furthermore, the contact resistance of the Relay will gradually become unstable due to the generation of film on the con- tact surfaces. A Latching Relay can be used to prevent these pro b- lems. When using a non-latching relay, the design of the fail-safe circuit provides protection against contact failure and open coils. Handling of Surface-mounting Relays Use the Relay as soon as possi ble after opening the moisture-proof package. If the Relay is left for a long time after opening the mois- ture-proof package, the appearance may suffer and seal failure may occur after the solder mounting process. To store the Relay after opening the moisture-proof package, pl ace it into the original pack- age and seal the package with adhesive tape. When washing the product after soldering the Relay to a PCB, use a water-based solvent or alcohol- based solvent, and keep the solvent temperature at less than 40°C. Do not put the relay in a cold cleaning bath immediately after soldering. Soldering Solder: JIS Z3282, H63A Soldering temperature: Approx. 250°C (At 260°C if the DWS method is used.) Soldering time: Approx. 5 s max. (Approx. 2 s for the first time and approx. 3 s for the second time if the DWS method is used.) Be sure to adjust the level of the molten solder so that the solder will not overflow onto the PCB. Claw Securing Force During Automatic Insertion During automatic insertion of Relays, make sure to set the securing force of the claws to the following values so that the Relay character- istics will be maintained. Environmental Conditions During Operation, Storage, and Transportation Protect the Relays from direct sunlight and keep the Relays under normal temperature, humidity, and pressure. Mounting Latching Relays The Latching Relays are reset before shipping. If excessive vibration or shock is imposed, however, the Latching Relays may be set acci- dentally. Be sure to apply a reset signal before use. Make sure that the vibration or shock that is generated by other devices on the same panel does not exceed the rated value of the Latching Relays. Maximum Voltage The maximum voltage of the coil can be obtained from the coil tem- perature increase and the heat-resisti ng temperature of coil insulat- ing sheath material. (Exceeding t he heat-resisting temperature may result in burning or short-circuiting.) The maximum voltage also involves important restrictions. Maximum voltage:  must not cause thermal changes or deterioration of the insulating material.  must not cause damage to other control devices.  must not cause any harmful effect on people.  must not cause fire. Therefore, be sure not to exceed the maximum voltage specified in the catalog. As a rule, the rated voltage must be applied to the coil. A voltage exceeding the rated value, however, can be applied to the coil pro- vided that the voltage is less than the maximum voltage. It must be noted that continuous voltage applicat ion to the coil will cause a coil temperature increase which could deteriorate the coil insulation, shorten the relay’s electrical life, or affect various characteristics of the relay. Coating Relays mounted on PCBs may be coated or washed. Do not apply coatings or detergents containing silicone. Other Handling Dropping the relay may impose excess shock that exceeds the spec- ifications. Do not use any relay that has been dropped. A C B Direction A: 4.90 N max. Direction B: 9.80 N max. Direction C: 9.80 N max. Secure the claws to the area indicated by shading. Do not attach them to the center area or to only part of the Relay.

Surface-mounting Relay G6J-Y MEMO

Surface-mounting Relay G6J-Y OMRON ON-LINE Global - http://www.omron.com USA - http://www.components.omron.com Cat. No. X301-E-1b Printed in USA OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 09/11 Specifications subject to change without notice All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.