DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

G D N G6DN PCB Power Relay SPST Slim Power Relay for 5 A switching

  • Slim 5-mm width and miniature size. (20 × 5.08 × 12.5 mm)  High switching capability 5 A (250 VAC and 30 VDC), and high contact reliability by crossbar-twin contact.  Low power consumption 110 mW.  Meets application standards EN61010-1 and EN61010-2-201 for reinforced insulation (CTI 600 V min. and Rated insulation voltage 300 V).  Actualize electrical durability 100 Kops (-L type) ■Model Number Legend 123 4 ■Application Examples  Programmable Controller output  Temperature Controller  Building Automation  Output of control system ■Ordering Information ■Ratings
  • Coil Note. The rated current and resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. * Operating voltage is less than 72% when the relay is sideways and the marking is right way.
  • Contacts * Au plating is applied to stationary contact. 1. Number of Poles 1: 1-pole 2. Contact Form A: SPST -NO (1a) 3. Enclosure Rating None: Fully sealed 4. Classification None: Standard (E-LIFE 80 Kops) L: High durability type (E-LIFE 100 Kops) Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard SPST -NO (1a) Fully sealed PCB terminal G6DN-1A 25 pcs/ tube High durability G6DN-1A-L Classification Rated voltage Rated current (mA) Coil resistance (Ω) Must operate voltage (V) Must release voltage (V) Max. voltage (V) Power consumption (mW)% of rated voltage Standard 4.5 VDC 24.4 184 70% max. * 5% min. 160% Approx. 110 5 VDC 22.0 227 12 VDC 9.2 1,309 24 VDC 4.6 5,236 High durability 5 VDC 36.0 139 Approx. 18012 VDC 15.0 800 24 VDC 7.5 3,200 Resistive load Inductive load (cos φ = 0.4, L/R = 7 ms) Contact Type Cross bar twin Contact material Ag-Alloy and Au plating * Rated load 5 A at 250 VAC

5 A at 30 VDC

2 A at 250 VAC

2 A at 30 VDC

Max. switching voltage 277 VAC, 125 VDC Max. switching current 5 A Note. When ordering, add the rated coil voltage to the model number. Example: G6DN-1A DC5 However, the notation of the coil voltage on the product case as well as on the packaging will be marked as @@ VDC. Example: G6DN-1A 5VDC Rated coil voltage

G D N ■Characteristics Note 1. Values in the above table are initial values. Note 2. The contact resistance is measured with 1 A applied at 5 VDC using a fall-of-potential method. Note 3. The insulation resistance is measured between coil and contacts and between contacts of the same polarity at 500 VDC. * This value was measured at a switching frequency of 120 operations/min. Standard High durability Contact resistance 100 mΩ max. Operate time 10 ms max. Release time 5 ms max. Insulation resistance 1,000 MΩ min. (at 500 VDC) Dielectric strength Between coil and contacts 3,000 VAC, 50/60 Hz for 1 min Between contacts of the same polarity 750 VAC, 50/60 Hz for 1 min Surge withstand voltage Between coil and contacts 6 kV (1.2 ✕ 50 μs) Vibration resistance Destruction 10 to 55 to 10 Hz, 2.5 mm single amplitude (5.0 mm double amplitude) Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Shock resistance Destruction 1,000 m/s2 Malfunction 100 m/s2 Durability Mechanical 20,000,000 operations min. (at 18,000 operations/hr) Electrical 100,000 operations min. (3 A at 250 VAC, 3 A at 30 VDC Resistive load) 80,000 operations min. (5 A at 250 VAC, 5 A at 30 VDC Resistive load) 100,000 operations min. (2 A at 250 VAC, 2 A at 30 VDC Inductive load) 100,000 operations min. (5 A at 250 VAC, Resistive load) 100,000 operations min. (5 A at 30 VDC, Resistive load) 200,000 operations min. (2 A at 250 VAC, Inductive load) 200,000 operations min. (2 A at 30 VDC, Inductive load) Failure rate (P level) (reference value) * 0.1 mA at 0.1 VDC Ambient temperature Operating -40°C to +90°C (with no icing or condensation) Humidity 5% RH to 85% RH Weight Approx. 3 g

G D N ■Engineering Data ■Dimensions

  • Maximum Switching Capacity G6DN-1A, G6DN-1A-L
  • Durability G6DN-1A
  • Ambient Temperature vs. Maximum Coil Voltage G6DN-1A, G6DN-1A-L Note. The maximum coil voltage refers to the maximum voltage in a varying range of operating power voltage, not a continuous voltage.
  • Ambient Temperature vs. Must Operate and Must Release Voltages G6DN-1A, G6DN-1A-L
  • Shock Malfunction 0.5 0.3 0.1 13 5 1 0 3 0 100 125 277 500 1,000 Switching current (A) AC resistive load DC resistive load Switching voltage (V) 2.5 0.4

250 VAC/30 VDC

Durability (x104 operations) Switching current (A) 1 2 3 4 5 6 7 8 9 10 500 300 100 0 2 3 3 04 05 06 07 0 8 0 9 0 100 Maximum coil voltage (%) Ambient temperature (°C) 126 0 20 40 60 80 100−20−60 −40 max. min. max. min. Ambient temperature (°C) Must operate and must release voltage (ratio of rated voltage) (%) X X Z Z Y Y X X 1,000 1,000 800 600 400 200 1,000 1,000 1,000 1,000 De-energized Energized Shock direction Unit: m/s2 Coil terminals Sample: G6DN-1A Number of Relays: 5 pcs Test conditions: Impose a shock in the ±X, ±Y, and ±Z directions three times each with the Relay energized to check the shock values that cause the Relay to malfunction. Standard:100 m/s 20 max. (19.97)* 5.08 max. (5.05)* 12.5 max. (12.45)* Two, 0.4-dia. 2.54 2-0.8 3.3 1.32 1.28 2.54±0.1 7.62±0.1 7.62±0.1 (1.32) (1.28) 7.62 7.62 1 2 5 8 Four, 1.1-dia. holes * Average value t 0.26t 0.2 G6DN-1A(-L) Terminal Arrangement/ Internal Connections (Bottom View) PCB Mounting Holes (Bottom View) (No coil polarity)

G D N ■Approved Standards

  • The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this datasheet. UL/C-UL-approved models (File No. E41515) Note. CSA certification CSA 22.2 No.14 can be recognized by C-UL. VDE (EN61810-1) (Certificate No. 40042696) ■Precautions
  • Please refer to “PCB Relays Common Precautions” for correct use. Model Contact form Coil ratings Contact ratings Operations G6DN-1A SPST-NO 4.5 to 24 VDC

5 A at 277 VAC (Resistive) 95°C 6,000

5 A at 30 VDC (Resistive) 90°C 6,000

1/10 hp 125 VAC 95°C 1,000 1/10 hp 277 VAC 95°C 1,000 D300 120 VAC/240 VAC 95°C 6,000 C300 120 VAC/240 VAC 95°C 6,000 R300 125 VDC/250 VDC 95°C 6,000 G6DN-1A-L SPST-NO 5 to 24 VDC

5 A 250 VAC (Resistive) 95°C 100,000

2 A 250 VAC (General Use) 95°C 100,000

2 A 30 VDC (General Use) 95°C 100,000

1/10 hp 120 VAC 40°C 6,000 C300 120 VAC/240 VAC 95°C 6,000 D150 120 VAC 95°C 6,000 R150 125 VDC 95°C 6,000 Model Contact form Coil ratings Contact ratings Operations G6DN-1A SPST-NO 4.5 to 24 VDC 5 A at 250 VAC (cosφ= 1.0) 90°C 10,000

5 A at 30 VDC (L/R = 0 ms) 90°C 10,000

G6DN-1A-L SPST-NO 5 to 24 VDC 5 A 250 VAC (cosφ= 1.0) 90°C 100,000 2 A 250 VAC (cosφ= 0.4) 90°C 100,000 2 A 250 VAC (cosφ= 0.6) 90°C 100,000

5 A 30 VDC (L/R = 0 ms) 90°C 100,000

2 A 30 VDC (L/R = 7 ms) 90°C 100,000

Clearance distance 3.5 mm min. Creepage distance 3.6 mm min. Type of insulation coil-contact circuit open contact circuit Basic (PD.2) Micro disconnection Rated Insulation voltage 300 V Pollution degree 2 Rated voltage system 250 V Over voltage category II Category of protection according to IEC 61810-1 RT III (Sealed) Insulation material group I Tracking resistance according to IEC 60112 CTI 600 V min. Flammability class according to UL94 V-0 Coil insulation system according to UL Class B

  • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
  • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the prod uct provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. K276-E1-07 0817(1115)(O) Note: Do not use this document to operate the Unit.