G6AK-274P-STLT-US-DC5 OMRON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 8

Technical content

Fullly Sealed Relay with High Impulse Withstand

  • High sensitivity — can be driven by digital circuits.  Low-profile design allows use in 12.70 mm PC board rack.  Surge withstand voltage meets FCC Part 68 regulation.  Units can be mounted side by side due to low magnetic leakage.  Special models available for low thermoelectromotive force.  Unique moving loop (permanent magnet) armature reduces relay size, magnetic interference, and contact bounce time.  Single or dual coil winding types available.  RoHS Compliant RC FCC

Ordering Information

To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST -US-DC12). ■Non-latching ■Latching Single Coil Dual Coil Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US Type Contact form Model Ag (Au clad) Standard DPDT G6AU-274P-ST-US Type Contact form Model Ag (Au clad) Standard DPDT G6AK-274P-ST-US Low-sensitivity DPDT G6AK-274P-ST40-US

68 Low Signal Relay G6A

■Contact Data * 0.25A at 125VAC for latching models Note: P level: λ60 = 0.1 x 10–6/operation This value was measured at a switching frequency of 60 operations/min and the criterion of contact resistance is 50 Ω. This value may vary depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions. ■Coil Data Standard Non-latching DPDT (G6A-274P-ST-US) Low-sensitivity Non-latching DPDT (G6A-274P-ST40-US) Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. Operating characteristics are measured at a coil temperature of 23°C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil. Type G6A-274P-ST(40)-US G6AK-274P-ST(40)-US G6AU-274P-ST-US (L/R = 7 ms) Rated load 0.50 A at 125 VAC,

2 A at 30 VDC

0.3 A* at 125 VAC,

1 A at 30 VDC

Contact material Ag (Au clad) Carry current 3 A Max. operating voltage 250 VAC, 220 VDC Max. operating current 2 A 1 A Max. switching capacity 125 VA, 60 W 62.50 VA, 30 W Min. permissible load (See note) 10 μA, 10 mVDC Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) Coil inductance (ref. value) (H) Pick-up voltage Dropout voltage Maximum voltage Power consumption (mW)Armature OFF Armature ON % of rated voltage at 23°C Approx. 200 4.5 44.6 101 0.16 0.14 5 40 125 0.20 0.18 6 33.30 180 0.29 0.26 9 22.20 405 0.63 0.57 12 16.70 720 1.10 1.06 24 8.30 2,880 4.50 4.10 48 4.90 9,750 13.70 12.50 Approx. 235 Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) Coil inductance (ref. value) (H) Pick-up voltage Dropout voltage Maximum voltage Power consumption (mW)Armature OFF Armature ON % of rated voltage at 23 Approx. 400 5 80 62.50 0.08 0.07 6 66.70 90 0.11 0.10 9 44.30 203 0.27 0.23 12 33.30 360 0.52 0.43 24 16.70 1,440 2.10 1.80 48 8.30 5,760 7.50 6.40

Standard Single Coil Latching DPDT (G6AU-274P-ST-US) Standard Dual Coil Latching DPDT (G6AK-274P-ST-US) Low-sensitivity Dual Coil Latching DPDT (G6AK-274P-ST40-US) Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. Operating characteristics are measured at a coil temperature of 23°C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil. Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) Coil inductance (ref. value) (H) Set pick-up voltage Reset pick- up voltage Maximum voltage Power consumption (mW)Armature OFF Armature ON % of rated voltage at 23°C Approx. 100 4.5 22.2 202 0.34 0.25 5 20 250 0.44 0.35 6 16.70 360 0.64 0.48 9 11.10 810 1.38 1.07 12 8.30 1,440 2.50 2 24 4.20 5,760 9.20 7.20 48 2.50 19,000 28.50 22 Approx. 120 Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) Coil inductance (ref. value) (H) Set pick-up voltage Reset pick-up voltage Maximum voltage Power consumption (mW)Set coil Reset coil Armature OFF Armature ON Armature OFF Armature ON % of rated voltage at 23°C Approx. 200 5 36 139 0.11 0.08 0.08 0.11 6 30 200 0.16 0.12 0.12 0.16 9 20 450 0.38 0.28 0.28 0.38 12 15 800 0.60 0.45 0.45 0.60 Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) Coil inductance (ref. value) (H) Set pick-up voltage Reset pick-up voltage Maximum voltage Power consumption (mW)Set coil Reset coil Armature OFF Armature ON Armature OFF Armature ON % of rated voltage at 23°C Approx. 360 6 60 100 0.07 0.05 0.05 0.07 9 40 225 0.16 0.12 0.12 0.16 12 30 400 0.28 0.20 0.20 0.28 24 15 1,600 1.10 0.75 0.75 1.10 48 7.50 6,400 4 2.90 2.9 4

70 Low Signal Relay G6A

■Characteristics Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method. 2. Values in parentheses are typical values unless otherwise stated. 3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those for checking the dielectric strength (except between the set and reset coil). 4. The above values are initial values. ■Approvals UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp. = 40°C Note: 1. The rated values approved by each of the safety standards (e.g ., UL and CSA) may be different fr om the performance characterist ics individually defined in this catalog. 2. In the general interest of product improvement, specifications are subject to change. Type Non-latching Latching Contact resistance (See note 1) 50 mΩ max. Operate (set) time (See note 2) Release (reset) time (See note 2) Min. set/reset signal width DPDT 7 ms min. Operating frequency Mechanical 36,000 operations/hour Electrical 1,800 operations/hour (under rated load) Insulation resistance (See note 3) 1,000 MΩ min. (at 500 VDC); except for set-reset Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between coil and contacts 1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles 1,000 VAC, 50/60 Hz for 1 minute between contacts of same pole

250 VAC, 50/60 Hz for 1 minute between set and reset coils

Surge withstand voltage 1,500 V (10 x 160 μs) (conforms to FCC Part 68) Vibration Mechanical durability 10 to 55 Hz; 5 mm double amplitude Malfunction durability 10 to 55 Hz; 3.3 mm double amplitude Shock Mechanical durability 1,000 m/s 2 (Approx. 100G Malfunction durability DPDT: 500 m/s2 (Approx. 50 G) Ambient temperature -40° to 70°C with no icing Humidity 5% to 85% RH Service life Mechanical 100 million operations min. (at 36,000 operations/hour) Electrical 500,000 operations min. (at 1,800 operations/hr) See “Characteristic Data” Weight DPDT Approx. 3.5 g 4PDT Approx. 6.0 g Type Contact form Coil rating Contact ratings Number of test operations G6A( )-274P-ST( )-US DPDT 1.5 to 48 VDC 1 A at 125 VAC (General Purpose)

2 A at 30 VDC (General Purpose)

0.6 A at 110 VDC (General Purpose)

6,000

■Characteristic Data Maximum Switching Capacity DPDT Ambient Temperature vs. Maximum Coil Voltage Switching current (A) Rated Operating voltage (V)A m bient temperature (°C) Maximum coil voltage (%) DC inductive (L/R = 7 ms) AC inductive (cosf = 0.4) DC resistive AC resistive DPDT: 360, 400 mW DPDT: 100, 180, 200 mW Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Electrical Service Life DPDT Rated operating current (A) Service Life (x10 operations)6 -234P 30 VDC, resistive; -274P 30 VDC, inductive -274P 30 VDC, resistive -234P 125 VAC, resistive -274P 125 VAC, resistive; -234P 30 VDC, inductive 234P 125 VAC, inductive -274P 125 VAC, inductive 100 0.5 0.3 0.1 0.05 0.03

72 Low Signal Relay G6A

Note: 1. All units are in millimeters unless otherwise indicated. 2. Orientation marks are indicated as follows: ■Non-latching G6A-274P-ST(40)-US ■Latching G6AU-274P-ST-US G6AK-274P-ST(40)-US Precautions Long-term Continuously ON Contacts Using the Relay in a circuit wher e the Relay will be ON continuously for long periods (without switching) can lead to unstable contacts because the heat generated by the coil itself will affect the insulation, causing a film to develop on the contact surfaces. Be sure to use a fail-safe circuit design that provides protection against contact failure or coil burnout. Otherwise, use a latching relay. Relay Handling When washing the product after soldering the Relay to a PCB, use a water-based solvent or alcohol-based solvent, and keep the solvent temperature to less than 40 °C. Do not put the Relay in a cold clean- ing bath immediately after soldering. Terminal Arrangement/ Internal Connections (Bottom View) Mounting Holes (Bottom View) Tolerance: ±0.1 7.62 (1.2) (1.2) (1.2) Eight, 1.0-dia. holes 20.2 max. (20)* 0.6 10.1 max. (9.9)* 8.4 max. (8.2)*0.64 7.62 0.3 3.16 *Average value 20.2 max. (20)* 0.6 10.1 max. (9.9)* 8.4 max. (8.2)*0.64 7.62 0.3 3.16 Terminal Arrangement/ Internal Connections (Bottom View) Mounting Holes (Bottom View) Tolerance: ±0.1 + - - + S R 7.62 (1.2) (1.2) (1.2) Eight, 1.0-dia. holes*Average value 20.2 max. (20)* 0.6 10.1 max. (9.9)* 8.4 max. (8.2)*0.64 7.62 0.3 3.16 Terminal Arrangement/ Internal Connections (Bottom View) Mounting Holes (Bottom View) Tolerance: ±0.1 SR 2.54 5.08 5.08 (1.2) 7.62 (1.2) (1.2) (1.2) 5.08 Ten, 1-dia. holes*Average value

Global - http://www.omron.com USA - http://www.components.omron.com Cat. No. X301-E-1b Printed in USA OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 09/11 Specifications subject to change without notice All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.